Optimization and validation of a LC-HRMS method for aflatoxins determination in urine samples

被引:11
|
作者
Debegnach, Francesca [1 ]
Brera, Carlo [1 ]
Mazzilli, Gianmarco [1 ]
Sonego, Elisa [1 ]
Buiarelli, Francesca [2 ]
Ferri, Fulvio [3 ]
Rossi, Paolo Giorgi [4 ]
Collini, Giorgia [4 ]
De Santis, Barbara [1 ]
机构
[1] Ist Super Sanita, Reparto Sicurezza Chim Alimenti, Viale Regina Elena 299, I-00161 Rome, Italy
[2] Sapienza Univ Roma, Dipartimento Chim, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[3] SPSAL AUSL, Serv Prevenz Sicurezza Ambienti Lavoro, Via Giovanni Amendola 2, I-42122 Reggio Emilia, Italy
[4] AUSL IRCCS, Serv Epidemiol, Via Giovanni Amendola 2, I-42122 Reggio Emilia, Italy
关键词
Biomonitoring; Biomarker; Mycotoxin; Aflatoxin; Metabolites; LC-Orbitrap; LC-HRMS; OCCUPATIONAL-EXPOSURE; BIOMARKERS; MYCOTOXINS; WORKERS; CANCER; WHEAT;
D O I
10.1007/s12550-020-00389-6
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Mycotoxins' exposure by inhalation and/or dermal contact can occur in different branches of industry especially where heavily dusty settings are present and the handling of dusty commodities is performed. This study aims to explore the possible contribution of the occupational exposure to aflatoxins by analysing urine samples for the presence of aflatoxins B-1 and M-1 and aflatoxin B-1-N-7-guanine adduct. The study was conducted in 2017 on two groups of volunteers, the workers group, composed by personnel employed in an Italian feed plant (n = 32), and a control group (n = 29), composed by the administrative employees of the same feed plant; a total of 120 urine samples were collected and analysed. A screening method and a quantitative method with high-resolution mass spectrometry determination were developed and fully validated. Limits of detections were 0.8 and 1.5 pg/mL(urine) for aflatoxin B-1 and M-1, respectively. No quantitative determination was possible for the adduct aflatoxin B-1-N-7-guanine. Aflatoxin B-1 and its adduct were not detected in the analysed samples, and aflatoxin M-1, instead, was found in 14 samples (12%) within the range 1.9-10.5 pg/mL(urine). Only one sample showed a value above the limit of quantification (10.5 pg/mL(urine)). The absence of a statistical difference between the mean values for workers and the control group which were compared suggests that in this specific setting, no professional exposure occurs. Furthermore, considering the very low level of aflatoxin M-1 in the collected urine samples, the contribution from the diet to the overall exposure is to be considered negligible.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 50 条
  • [1] Optimization and validation of a LC-HRMS method for aflatoxins determination in urine samples
    Francesca Debegnach
    Carlo Brera
    Gianmarco Mazzilli
    Elisa Sonego
    Francesca Buiarelli
    Fulvio Ferri
    Paolo Giorgi Rossi
    Giorgia Collini
    Barbara De Santis
    Mycotoxin Research, 2020, 36 : 257 - 266
  • [2] Development and validation of a method for analyzing the sialylated glycopeptides of recombinant erythropoietin in urine using LC-HRMS
    Seo, Yoondam
    Park, Jisoo
    Lee, Hyeon-Jeong
    Kim, Minyoung
    Kang, Inseon
    Son, Junghyun
    Oh, Min-Kyu
    Min, Hophil
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [3] Evaluation of sampling adsorbents and validation of a LC-HRMS method for determination of 28 airborne pesticides
    Lopez, Antonio
    Coscolla, Clara
    Yusa, Vicent
    TALANTA, 2018, 189 : 211 - 219
  • [4] Determination of contaminants in turmeric: Validation of LC-HRMS methods for the determination of pesticides and mycotoxins
    Llano, Sandra
    Henao, Carolina
    Maria Gomez, Ana
    Gallo Ortiz, Andres Fernando
    MICROCHEMICAL JOURNAL, 2023, 186
  • [5] Determination of adulteration in hair serums by LC-HRMS
    Akaslan, T. Cagdas
    Yalcin, Sule
    Akyildiz, Aysenur Gunaydin
    Goren, Ahmet C.
    JOURNAL OF CHEMICAL METROLOGY, 2023, 17 (01): : 93 - 99
  • [6] Detection of the GH analogue somatrogon in doping control urine samples by means of LC-HRMS/MS
    Katja Walpurgis
    Andreas Thomas
    Alexandra Rauer
    Bettina Majer
    Mitsuhiko Sato
    Masato Okano
    Maneera Al-Jaber
    Wadha Abushareeda
    Cristian-Gabriel Arsene
    Hans Geyer
    Mario Thevis
    Scientific Reports, 15 (1)
  • [7] Quantitative determination of atenolol in dried blood spot samples by LC-HRMS: A potential method for assessing medication adherence
    Lawson, Graham
    Cocks, Elizabeth
    Tanna, Sangeeta
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 897 : 72 - 79
  • [8] Development and validation of a LC-HRMS method for the quantification of cannabinoids and their metabolites in human plasma
    Mohamed, Mahmoud Kamel
    Takyi-Williams, John
    Baudot, Bertrand
    Grobler, Anne
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 159
  • [9] Identification of etazene (etodesnitazene) metabolites in human urine by LC-HRMS
    Verougstraete, Nick
    Verhaeghe, Annick
    Germonpre, Jan
    Lebbinck, Herve
    Verstraete, Alain G.
    DRUG TESTING AND ANALYSIS, 2023, 15 (02) : 235 - 239
  • [10] Development and validation of an LC-HRMS method for the determination of pyrrolizidine alkaloids and quinolones in honey employing a simple alkaline sample dilution
    Thiago Bousquet Bandini
    Bernardete Ferraz Spisso
    Journal of Food Measurement and Characterization, 2021, 15 : 4758 - 4770