The paradoxical stimulation by a reversible thrombin inhibitor of thrombin generation in plasma measured with thrombinography is caused by α2-macroglobulin-thrombin

被引:37
作者
Wagenvoord, R. J. [1 ]
Deinum, J. [2 ]
Elg, M. [2 ]
Hemker, H. C. [1 ]
机构
[1] Univ Maastricht, Synapse BV, CARIM, Maastricht, Netherlands
[2] AstraZeneca R&D, Molndal, Sweden
关键词
calibrated automated thrombinography; reversible direct thrombin inhibitors; sub-sampling technique; thrombin generation; HEMOPHILIA-A; THROMBOGRAM; HEPARIN; RISK;
D O I
10.1111/j.1538-7836.2010.03822.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Thrombin generation (TG) in plasma can be monitored continuously with a fluorogenic thrombin substrate using calibrated automated thrombinography ( CAT). In the presence of low concentrations of a reversible direct thrombin inhibitor (DTI), CAT shows an unexpected effect: the endogenous thrombin potential (ETP) increases at low concentrations of the inhibitor to subsequently decrease concentration dependently at higher concentrations (> approximately 100 nM). Objectives. To find an explanation for this phenomenon, we measured the concentrations of free thrombin and alpha(2)-macroglobulin- thrombin complex (alpha 2MT) with a sub-sampling technique in the presence of AR-H067637, a selective DTI. Results. At all concentrations of the DTI there was a gradual dose-dependent decrease in the concentration of free, not-inhibited thrombin but a transient increase in free alpha 2MT due to competition of thrombin and alpha 2MT for the inhibitor. Because the CAT technique uses an algorithm to subtract alpha 2MT activity from the total amidolytic activity, this transient increase in alpha 2MT activity is not subtracted and erroneously attributed to thrombin itself. Conclusions. This study explains the spurious increase in ETP observed at low DTI concentrations. The results obtained in plasma were corroborated by observations in a thrombin generating system reconstituted with purified factors. In practise, the effect of DTIs on TG can be reliably evaluated from the area under the curve till time-to-peak.
引用
收藏
页码:1281 / 1289
页数:9
相关论文
共 22 条
[1]   A SIMPLIFIED PROCEDURE FOR PURIFICATION OF HUMAN-PROTHROMBIN, FACTOR-IX AND FACTOR-X [J].
BAJAJ, SP ;
RAPAPORT, SI ;
PRODANOS, C .
PREPARATIVE BIOCHEMISTRY, 1981, 11 (04) :397-412
[2]  
BARRETT AJ, 1981, METHOD ENZYMOL, V80, P737
[3]  
BEGUIN S, 1988, THROMB HAEMOSTASIS, V60, P457
[4]   The central role of thrombin in hemostasis [J].
Crawley, J. T. B. ;
Zanardelli, S. ;
Chion, C. K. N. K. ;
Lane, D. A. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 :95-101
[5]   Major surgery in a severe haemophilia A patient with high titre inhibitor: use of the thrombin generation test in the therapeutic decision [J].
Dargaud, Y ;
Lienhart, A ;
Meunier, S ;
Hequet, O ;
Chavanne, H ;
Chamouard, V ;
Marin, S ;
Negrier, C .
HAEMOPHILIA, 2005, 11 (05) :552-558
[6]   Evaluation of thrombin generating capacity in plasma from patients with haemophilia A and B [J].
Dargaud, Y ;
Béguin, S ;
Lienhart, A ;
Al Dieri, R ;
Trzeciak, C ;
Bordet, JC ;
Hemker, HC ;
Negrier, C .
THROMBOSIS AND HAEMOSTASIS, 2005, 93 (03) :475-480
[7]   Biochemical and pharmacological effects of the direct thrombin inhibitor AR-H067637 [J].
Deinum, Johanna ;
Mattsson, Christer ;
Inghardt, Tord ;
Elg, Margareta .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (06) :1051-1059
[8]  
Di Cera E, 2007, J THROMB HAEMOST, V5, P196
[9]   The interaction between captured human thrombin and antithrombin studied by surface plasmon resonance, and the effect of melagatran [J].
Elg, S ;
Deinum, J .
SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2002, 16 (3-4) :257-270
[10]   The technique of measuring thrombin generation with fluorescent substrates: 4. The H-transform, a mathematical procedure to obtain thrombin concentrations without external calibration [J].
Hemker, H. Coen ;
Hemker, Pieter W. ;
Al Dieri, Raed .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (01) :171-177