A voltammetric biosensor based on poly(o-methoxyaniline)-gold nanocomposite modified electrode for the simultaneous determination of dopamine and folic acid

被引:36
|
作者
Sangamithirai, D. [1 ]
Munusamy, S. [2 ]
Narayanan, V [2 ]
Stephen, A. [1 ]
机构
[1] Univ Madras, Dept Nucl Phys, Mat Sci Ctr, Guindy Campus, Madras 600025, Tamil Nadu, India
[2] Univ Madras, Dept Inorgan Chem, Guindy Campus, Madras 600025, Tamil Nadu, India
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2018年 / 91卷
关键词
Poly(o-methoxyaniline); Gold nanoparticles; Voltammetric sensor; Dopamine; Folic acid; Simultaneous determination; GOLD NANOPARTICLES; URIC-ACID; ELECTROCHEMICAL DETERMINATION; ELECTROCATALYTIC OXIDATION; METAL NANOPARTICLES; PASTE ELECTRODE; ASCORBIC-ACID; FABRICATION; SENSOR; POLYANILINE;
D O I
10.1016/j.msec.2018.05.070
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Dopamine (DA) and Folic acid (FA) are co-existing compounds in biological fluids that plays a vital role in central nervous system and human metabolism. DA is an important neurotransmitter in the brain's neural circuits and its diminution often results in Parkinson's disease. Folate is another form of folic acid, which is known as one of the B vitamins. It is utilized as an additive by women during pregnancy in order to prevent the neural tube defects. The present study reports on the fabrication of electrochemical sensor for the simultaneous determination of DA and FA using poly(o-methoxyaniline)-gold (POMA-Au) nanocomposite. The POMA-Au nanocomposite was prepared via insitu chemical oxidative polymerization method and characterized using X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM) and X-ray photoelectron spectroscopy (XPS). The suitability of POMA-Au nanocomposite as a modifier for the electrocatalytic detection of DA and FA in aqueous solution was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) techniques. The fabricated POMA-Au/GCE sensor exhibited sharp and intense peaks towards the electro-oxidation of DA and FA as compared to bare electrode. The sensor exhibited the promising electron mediating behavior with well separated oxidation peaks with a potential difference of about 350.0 mV. The linear calibration plots of DA and FA were obtained from 10.0 to 300.0 mu M and 0.5 to 900.0 mu M with the detection limits of 0.062 mu M and 0.090 mu M, respectively. The reliability of this sensor was verified to be precise as well as sensitive for the determination of DA and FA in pharmaceutical samples and human urine samples.
引用
收藏
页码:512 / 523
页数:12
相关论文
共 50 条
  • [21] Simultaneous Determination of Dopamine, Serotonin and Folic acid at Torasemide Modified Carbon Paste Electrode: A Cyclic Voltammetric Study
    Sathisha, Arehalli
    KumaraSwamy, Bahaddurghatta E.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (05): : 589 - 603
  • [22] Zeolitic imidazolate frameworks and cobalt-tannic acid nanocomposite modified carbon paste electrode for simultaneous determination of dopamine, uric acid, acetaminophen and tryptophan: Investigation of kinetic parameters of surface electrode and its analytical performance
    Setoudeh, Nazmaryam
    Jahani, Shohreh
    Kazemipour, Maryam
    Foroughi, Mohammad Mehdi
    Nadiki, Hadi Hassani
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 863
  • [23] Simultaneous electrochemical determination of dopamine and ascorbic acid using poly (L-serine) modified carbon paste electrode
    Chitravathi, S.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Sherigara, B. S.
    JOURNAL OF MOLECULAR LIQUIDS, 2011, 160 (03) : 193 - 199
  • [24] Simultaneous voltammetric determination of dopamine and ascorbic acid at an electrode modified with the gold-palladium binary system
    L. G. Shaidarova
    I. A. Chelnokova
    A. V. Gedmina
    G. K. Budnikov
    Journal of Analytical Chemistry, 2009, 64 : 36 - 43
  • [25] Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups
    Wu, Feng
    Huang, Ting
    Hu, Yangjian
    Yang, Xin
    Ouyang, Yuejun
    Xie, Qingji
    MICROCHIMICA ACTA, 2016, 183 (09) : 2539 - 2546
  • [26] Simultaneous voltammetric determination of ascorbic acid and dopamine at the surface of electrodes modified with self-assembled gold nanoparticle films
    Raoof, Jahan Bakhsh
    Kiani, Abolfazl
    Ojani, Reza
    Valiollahi, Roudabeh
    Rashid-Nadimi, Sahar
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (07) : 1171 - 1176
  • [27] Functionalised carbon nano spheres modified electrode for simultaneous determination of dopamine and uric acid
    Dey, Milan Kumar
    Satpati, Ashis Kumar
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 787 : 95 - 102
  • [28] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Nian Bing Li
    Wang Ren
    Hong Qun Luo
    Journal of Solid State Electrochemistry, 2008, 12 : 693 - 699
  • [29] Nafion coated Au nanoparticle-graphene quantum dot nanocomposite modified working electrode for voltammetric determination of dopamine
    Jang, Hong-Sik
    Kim, Dongwon
    Lee, Chaedong
    Yan, Bingyi
    Qin, Xinyu
    Piao, Yuanzhe
    INORGANIC CHEMISTRY COMMUNICATIONS, 2019, 105 : 174 - 181
  • [30] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Li, Nian Bing
    Ren, Wang
    Luo, Hong Qun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (06) : 693 - 699