Objective: To evaluate the functional results obtained after stapedotomy in patients affected by otosclerosis, according to the prosthesis diameter. Patients and Methods: A retrospective case review was performed. Two hundred and twelve consecutive ears in 132 patients affected by otosclerosis were operated on. All patients underwent primary small-fenestra stapedotomy. In 112 of the 212 stapedotomies (52.83%) the 0.6-mm piston (group A) and in 100 of the 212 stapedotomies (47.16%) the 0.4-mm piston (group B) were employed. Results: After surgery, the difference between the two groups in the air conduction improvement (21.04 dB group A vs. 11.14 dB group B) reached statistical significance (p < 0.05). In group A, the postoperative air conduction pure-tone average improvement obtained at 0.5, 1, and 2 kHz was statistically greater as compared with group B (p > 0.05). In group A the postoperative bone conduction pure-tone average decreased by 5.19 dB, whereas in group B it increased by 2.95 dB (p > 0.05). The incidence of ears with a postoperative bone conduction worsening 1 10 dB (sensorineural hearing loss) was lower in group B than in group A: 5 of 100 ears (5%) versus 9 of 112 ears (8.03%) (p > 0.05). The postoperative air-bone gap was smaller in group A than in group B for all frequencies, but the difference can be considered significant at 1 and 2 kHz. The air-bone gap improvement in group A if compared with group B was statistically greater at 0.5, 1, and 2 kHz (p < 0.05). Conclusions: Our study suggests that an increase in piston diameter gives better results, especially at lower frequencies. The functional results obtained after stapedotomy confirm the advantageous effect of a larger piston diameter on hearing of the speech frequencies and support the opinion of a better clinical effect. Copyright (c) 2007 S. Karger AG, Basel.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 50 条
  • [1] Objective Evaluation of the Prosthesis Diameter on Hearing Results after Stapedotomy
    Karatas, Erkan
    Deniz, Hale Cam
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2012, 8 (01): : 51 - 56
  • [2] Hearing results after stapedotomy with a nitinol piston prosthesis
    Brown, Kevin D.
    Gantz, BruceJ.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2007, 133 (08) : 758 - 762
  • [3] Hearing results after stapedotomy for otosclerosis: comparison of prosthesis variables
    Odat, H.
    Kanaan, Y.
    Alali, M.
    Al-Qudah, M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2021, 135 (01): : 28 - 32
  • [4] Primary stapedotomy: Influence of prosthesis diameter on hearing outcome
    Salvador, Pedro
    Costa, Ricardo
    Silva, Francisco
    Fonseca, Rui
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2021, 72 (04): : 238 - 245
  • [5] Hearing and Otoacoustic Emissions Outcome of Stapedotomy: Does the Prosthesis Diameter Matter?
    Faranesh, Nabil
    Magamseh, Ebrahim
    Zaaroura, Suliman
    Zeidan, Reem
    Shupak, Avi
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2017, 13 (02): : 162 - 170
  • [6] Late Postoperative Hearing Results After Stapedotomy
    Tange, Rinze A.
    Grolman, Wilko
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2009, 5 (03): : 323 - 326
  • [7] Effect of teflon piston diameter on hearing result after stapedotomy
    Sennaroglu, L
    Ünal, ÖF
    Sennaroglu, G
    Gürsel, B
    Belgin, E
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2001, 124 (03) : 279 - 281
  • [8] Nitinol-Teflon Stapes Prosthesis Improves Low-Frequency Hearing Results After Stapedotomy
    Mangham, Charles A., Jr.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (07) : 1022 - 1026
  • [9] A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameter
    W. Grolman
    R. A. Tange
    A. J. G. de Bruijn
    A. A. M. Hart
    P. F. Schouwenburg
    European Archives of Oto-Rhino-Laryngology, 1997, 254 : 422 - 424
  • [10] A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameter
    Grolman, W
    Tange, RA
    de Bruijn, AJG
    Hart, AAM
    Schouwenburg, PF
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1997, 254 (9-10) : 422 - 424