Volumetric absorptive microsampling (VAMS) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development

被引:0
作者
Gao, Xinliu [1 ]
Chen, Cindy [2 ]
Geng, Dong [2 ]
Bateman, Kevin P. [2 ]
Shi, Shuangping [2 ]
Woolf, Eric J. [2 ]
Xu, Yang [2 ]
机构
[1] Merck & Co Inc, Analyt Res & Dev Mass Spectrometry, 2000 Galloping Hill Rd, Kenilworth, NJ 07033 USA
[2] Merck & Co Inc, Pharmacokinet Pharmacodynam & Drug Metab, 770 Sumneytown Pike,WP75B-300, West Point, PA 19486 USA
关键词
VAMS; Microsampling; Monoclonal antibody; LC-MS; Trypsin digestion; EDTA;
D O I
10.1016/j.jpha.2021.113895
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microsampling techniques have been employed as an alternative to traditional serum/plasma sampling because of their inherently proven and desirable advantages across the pharmaceutical industry. These include reduced animal usage in pre-clinical studies, as well as, permitting the collection of samples that would otherwise be inaccessible in clinical studies. The application of volumetric absorptive microsampling (YAMS) technology, a second-generation dried microsampling method, coupled with LC-MS, has been extensively explored for small molecule drugs at various drug development stages. However, the potential of using VAMS technology and LC-MS analysis for biological therapeutic development has yet to be well-established. In this work, we describe the method development, validation, and a proof-ofconcept non-human primate study of a LC-MS/MS method for VAMS utilized to obtain pharmacokinetic (PK) data for a therapeutic monoclonal antibody. A good correlation between VAMS data and data from conventional serum samples was established in rhesus monkeys and indicated the possibility of using of this novel sampling technology in clinical studies. However, during the initial clinical study, a significant difference in internal standard (IS) response between the patient fingerstick samples and the standard/QC samples was observed, which posed a question on the accuracy of the clinical results. A comprehensive investigation confirmed that the EDTA anticoagulant used in the standard/QC samples was the root cause of the observed anomalous IS responses. Special considerations and corresponding best practices during method development and validation are proposed to ensure early detection of potential issues and appropriate implementation of VAMS technology in clinical studies in the future. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 34 条
  • [1] Volumetric absorptive MicroSampling vs. other blood sampling materials in LC-MS-based protein analysis - preliminary investigations
    Andersen, Ida Kristine Lysgaard
    Rosting, Cecilie
    Gjelstad, Astrid
    Halvorsen, Trine Gronhaug
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 239 - 246
  • [2] Discovery stage pharmacokinetics using dried blood spots
    Beaudette, P
    Bateman, KP
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 153 - 158
  • [3] Validation of a Ligand Binding Assay Using Dried Blood Spot Sampling
    Burns, Daniel
    Brunner, Laura
    Rajendran, Surendran
    Johnson, Beth
    Ma, Mark
    Wang, Jin
    [J]. AAPS JOURNAL, 2013, 15 (01): : 123 - 131
  • [4] Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study
    De Kesel, Pieter M. M.
    Lambert, Willy E.
    Stove, Christophe P.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 881 : 65 - 73
  • [5] The effect of hematocrit on bioanalysis of DBS: results from the EBF DBS-microsampling consortium
    de Vries, Ronald
    Barfield, Matthew
    van de Merbel, Nico
    Schmid, Bernhard
    Siethoff, Christoph
    Ortiz, Jordi
    Verheij, Elwin
    van Baar, Ben
    Cobb, Zoe
    White, Steve
    Timmerman, Philip
    [J]. BIOANALYSIS, 2013, 5 (17) : 2147 - 2160
  • [6] Denniff P, 2010, BIOANALYSIS, V2, P1385, DOI [10.4155/bio.10.103, 10.4155/BIO.10.103]
  • [7] MRM-based multiplexed quantitation of 67 putative cardiovascular disease biomarkers in human plasma
    Domanski, Dominik
    Percy, Andrew J.
    Yang, Juncong
    Chambers, Andrew G.
    Hill, John S.
    Freue, Gabriela V. Cohen
    Borchers, Christoph H.
    [J]. PROTEOMICS, 2012, 12 (08) : 1222 - 1243
  • [8] THE EFFECTS OF DIVALENT CATIONS ON THE ENZYMATIC ACTIVITIES OF TRYPSIN AND OF ALPHA-CHYMOTRYPSIN
    GREEN, MM
    GLADNER, JA
    CUNNINGHAM, LW
    NEURATH, H
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1952, 74 (08) : 2122 - 2123
  • [9] GREEN NM, 1953, J BIOL CHEM, V204, P379
  • [10] Recommendations for Validation of LC-MS/MS Bioanalytical Methods for Protein Biotherapeutics
    Jenkins, Rand
    Duggan, Jeffrey X.
    Aubry, Anne-Francoise
    Zeng, Jianing
    Lee, Jean W.
    Cojocaru, Laura
    Dufield, Dawn
    Garofolo, Fabio
    Kaur, Surinder
    Schultz, Gary A.
    Xu, Keyang
    Yang, Ziping
    Yu, John
    Zhang, Yan J.
    Vazvaei, Faye
    [J]. AAPS JOURNAL, 2015, 17 (01): : 1 - 16