Efficacy and Safety of "I-Stop-Mini Adjustable" Sling System versus Transobturator Midurethral "Obtryx" Sling System in Stress Urinary Incontinence: A Retrospective Cohort Study

被引:7
作者
Chao, Wei-Ting [1 ,2 ,3 ,4 ,5 ]
Huang, Hsin-Yi [3 ,4 ]
Chen, Guan-Yeu [1 ,2 ,3 ,4 ,5 ]
Liu, Chia-Hao [2 ,3 ,4 ,5 ]
Chan, I-San [2 ,3 ,4 ,5 ]
Chang, Chia-Pei [2 ,3 ,4 ,5 ]
Chen, Yi-Jen [2 ,3 ,4 ,5 ]
Wang, Peng-Hui [2 ,3 ,4 ,5 ,6 ]
Horng, Huann-Cheng [2 ,3 ,4 ,5 ]
机构
[1] Fu Jen Catholic Univ, Coll Med, Fac Med, Taipei, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Fac Med, Sch Med, Taipei, Taiwan
[3] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Taipei 112, Taiwan
[5] Taipei Vet Gen Hosp, Dept Obstet & Gynecol, Taipei, Taiwan
[6] China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
关键词
Midurethral slings; Objective success; Tension-free vaginal tape; FREE VAGINAL TAPE; TVT-O; SINGLE; METAANALYSIS; MANAGEMENT; SECUR;
D O I
10.1016/j.jmig.2021.12.005
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To compare the safety, efficacy, and adverse events of the new mini-adjustable sling system "I-stop-mini " with transobturator midurethral slings "Obtryx " (Boston Scientific, Marlborough, MA) in women with stress urinary incontinence. Design: A single-center, retrospective cohort study. Setting: Department of Obstetrics and Gynecology, Taipei Veterans General Hospital, Taiwan. Patients: A total of 347 patients who underwent I-stop-mini or Obtryx for stress urinary incontinence treatment. Interventions: Midurethral sling with either I-stop-mini or Obtryx. Measurements and Main Results: The primary outcomes were objective success and subjective cure rates between the 2 groups. Objective success was evaluated using a 1-hour pad test, and subjective cure was evaluated using a questionnaire score (Incontinence Impact Questionnaire, Urinary Distress Inventory, and International Consultation on Incontinence Questionnaire Short Form). Secondary outcomes were the evaluation of surgical outcomes, operative data, and adverse events between the 2 groups. In total, 171 of 200 I-stop-mini subjects and 127 of 147 Obtryx subjects completed 12 months of follow-up. Regarding the objective success between the I-stop-mini group and the Obtryx group, 1-month postoperative (3.6 +/- 5.2 vs 3.9 +/- 12.6; p = .765), 6-month postoperative (3.9 +/- 5.1 vs 4.2 +/- 12.6; p = .848), and 12-month postoperative (4.6 +/- 5.6 vs 4.5 +/- 13.6; p = .980) 1-hour pad tests showed no significant difference. The 12-month subjective cure rates decreased from 94.7% (1-month postoperative) to 91.2% (12-month postoperative) in the I-stop-mini group and 95.2% (1-month postoperative) to 85.0% (12-month postoperative) in the Obtryx group. Similar and durable efficacy was observed between the 2 groups. The I-stop-mini group had shorter operative times and hospital stays than the Obtryx group; however, both groups showed similar adverse event rates. Conclusion: The objective success and subjective cure rates of I-stop-mini did not differ to those of Obtryx. However, long-term data and further prospective studies on I-stop-mini are necessary to arrive at a definite conclusion. (c) 2022 Published by Elsevier Inc. on behalf of AAGL.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 28 条
[1]   Contasure-NeedlelessA® compared with transobturator-TVTA® for the treatment of stress urinary incontinence [J].
Amat i Tardiu, Lluis ;
Martinez Franco, Eva ;
Lailla Vicens, Josep Maria .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2011, 22 (07) :827-833
[2]   Adjustable single-incision mini-slings (Ajust®) versus other slings in surgical management of female stress urinary incontinence: a meta-analysis of effectiveness and complications [J].
Bai, Fuding ;
Chen, Jimin ;
Zhang, Zhewei ;
Zheng, Yichun ;
Wen, Jiaming ;
Mao, Xiawa ;
Zhang, Nan .
BMC UROLOGY, 2018, 18
[3]   Are slings now the gold standard treatment for the management of female urinary stress incontinence and if so which technique? [J].
Bemelmans, BLH ;
Chapple, CR .
CURRENT OPINION IN UROLOGY, 2003, 13 (04) :301-307
[4]   Comparison of single-incision mini-slings (Ajust) and standard transobturator midurethral slings (Align) in the management of female stress urinary incontinence: A 1-year follow-up [J].
Chang, Chia-Pei ;
Chang, Wen-Hsun ;
Hsu, Yen-Mei ;
Chen, Yi-Jen ;
Wen, Kuo-Chang ;
Chao, Kuan-Chong ;
Yen, Ming-Shyen ;
Horng, Huann-Cheng ;
Wang, Peng-Hui .
TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2015, 54 (06) :726-730
[5]   Single incision mini-sling versus a transobutaror sling: a comparative study on MiniArc™ and Monarc™ slings [J].
De Ridder, Dirk ;
Berkers, Joost ;
Deprest, Jan ;
Verguts, Jasper ;
Ost, Dieter ;
Hamid, David ;
Van der Aa, Frank .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 (07) :773-778
[6]  
Delorme E, 2001, PROG UROL, V11, P1306
[7]   A randomized comparison of a single-incision needleless (Contasure-needlelessA®) mini-sling versus an inside-out transobturator (Contasure-KIMA®) mid-urethral sling in women with stress urinary incontinence: 24-month follow-up results [J].
Dogan, Ozan ;
Kaya, Aski Ellibes ;
Pulatoglu, Cigdem ;
Basbug, Alper ;
Yassa, Murat .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2018, 29 (09) :1387-1395
[8]   A prospective observational cohort study of the Ajust® single incision sling performed under conscious sedation with local infiltration [J].
Engberts, Marian K. ;
Schweitzer, Karlijn J. ;
van Eijndhoven, Hugo W. F. ;
Cromheecke, Geert-Jan ;
Naber, Harry R. ;
van der Vaart, C. Huub .
NEUROUROLOGY AND URODYNAMICS, 2019, 38 (06) :1632-1639
[9]   A Re-Adjustable Sling for Female Recurrent Stress Incontinence and Sphincteric Deficiency: Outcomes and Complications in 125 Patients Using the Remeex Sling System [J].
Errando, Carlos ;
Rodriguez-Escovar, Fernando ;
Gutierrez, Cristina ;
Baez, Carlos ;
Arano, Pedro ;
Villavicencio, Humberto .
NEUROUROLOGY AND URODYNAMICS, 2010, 29 (08) :1429-1432
[10]   Contasure-needlelessA® compared with MonarcA® for the treatment of stress urinary incontinence [J].
Fernandez-Gonzalez, Sergi ;
Martinez Franco, Eva ;
Miao, Xinxin Lin ;
Amat Tardiu, Lluis .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2017, 28 (07) :1077-1084