Modeling and Stability Analysis of LCL-Type Grid-Connected Inverters: A Comprehensive Overview

被引:87
作者
Han, Yang [1 ]
Yang, Mengling [1 ]
Li, Hong [2 ]
Yang, Ping [1 ]
Xu, Lin [3 ]
Alves Coelho, Ernane Antonio [4 ]
Guerrero, Josep M. [5 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Aviat Ind Corp China, Chengdu Aircraft Ind Corp, Chengdu 610092, Sichuan, Peoples R China
[3] Sichuan Elect Power Co, Sichuan Elect Power Res Inst, Chengdu 610072, Sichuan, Peoples R China
[4] Univ Fed Uberlandia, Fac Elect Engn, BR-38400902 Uberlandia, MG, Brazil
[5] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
LCL-filter; grid-connected inverters; parameters design; magnetic integration; damping methods; delay; stability; impedance-based stability analysis; impedance modeling; impedance measurement; DISTRIBUTED POWER-SYSTEMS; VOLTAGE-SOURCE CONVERTERS; ACTIVE DAMPING TECHNIQUE; TIME-DELAY COMPENSATION; FILTER DESIGN; OUTPUT FILTER; OPTIMIZED DESIGN; STATIONARY FRAME; INPUT-ADMITTANCE; DIGITAL-CONTROL;
D O I
10.1109/ACCESS.2019.2935806
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL filter has been widely adopted to interface between the inverter and the grid for improving the quality of injected grid currents. However, the high-order characteristics and various constraints of the LCL filter complicate the filter design. Moreover, the stability of the internal current control loop of the individual inverter is susceptible to the inherent LCL -filter resonance peak. Meanwhile, the overall system stability would be aggravated by the external interactions between the inverter and the weak grid as well as among the paralleled inverters. Both the LCL -filter resonance peak and two types of interaction would cause severely distorted grid currents. Motivated by the existing problems, a comprehensive review on the modeling and stability analysis of the LCL -type grid-connected inverters is conducted in this paper. Concretely, the generalized parameter constraints of the LCL filter are outlined to facilitate the passive components selection, and the magnetic integration techniques of filter inductors are also introduced to reduce the weight and size of filter for increasing the power density of the system. Then, the various damping methods for enhancing the individual internal stability and the relevant application issues are also discussed. Furthermore, the impedance-based method for evaluating the system-level interactive stability is subsequently reviewed, with the emphasis on different modeling methods of inverter output impedance and online impedance measurement techniques. Finally, the future research trends on the modeling and stability analysis of LCL -type grid-connected inverters are also presented.
引用
收藏
页码:114975 / 115001
页数:27
相关论文
共 202 条
[91]   An Efficient and Robust Hybrid Damper for LCL-or LLCL-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection [J].
Liu, Yuan ;
Wu, Weimin ;
He, Yuanbin ;
Lin, Zhe ;
Blaabjerg, Frede ;
Chung, Henry Shu-Hung .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (02) :926-936
[92]   A Variable Inductor Based LCL Filter for Large-Scale Microgrid Application [J].
Liu, Yusi ;
Mantooth, Homer Alan ;
Balda, Juan Carlos ;
Farnell, Chris .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) :7338-7348
[93]   Infinity-Norm of Impedance-Based Stability Criterion for Three-Phase AC Distributed Power Systems With Constant Power Loads [J].
Liu, Zeng ;
Liu, Jinjun ;
Bao, Weihan ;
Zhao, Yalin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (06) :3030-3043
[94]   An Interaction-Admittance Model for Multi-Inverter Grid-Connected Systems [J].
Lu, Minghui ;
Yang, Yongheng ;
Johnson, Brian ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (08) :7542-7557
[95]   Graphical Evaluation of Time-Delay Compensation Techniques for Digitally Controlled Converters [J].
Lu, Minghui ;
Wang, Xiongfei ;
Loh, Poh Chiang ;
Blaabjerg, Frede ;
Dragicevic, Tomislav .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (03) :2601-2614
[96]   Resonance Interaction of Multiparallel Grid-Connected Inverters With LCL Filter [J].
Lu, Minghui ;
Wang, Xiongfei ;
Loh, Poh Chiang ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) :894-899
[97]  
Luhtala R, 2017, IEEE ENER CONV, P69, DOI 10.1109/ECCE.2017.8095763
[98]  
Luhtala R, 2018, INT CONF POW ELECTR, P547, DOI 10.23919/IPEC.2018.8507736
[99]   Implementation of Real-Time Impedance-Based Stability Assessment of Grid-Connected Systems Using MIMO-Identification Techniques [J].
Luhtala, Roni ;
Roinila, Tomi ;
Messo, Tuomas .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) :5054-5063
[100]   Modeling and Control of N-Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants [J].
Luis Agorreta, Juan ;
Borrega, Mikel ;
Lopez, Jesus ;
Marroyo, Luis .