Modeling and Stability Analysis of LCL-Type Grid-Connected Inverters: A Comprehensive Overview

被引:87
作者
Han, Yang [1 ]
Yang, Mengling [1 ]
Li, Hong [2 ]
Yang, Ping [1 ]
Xu, Lin [3 ]
Alves Coelho, Ernane Antonio [4 ]
Guerrero, Josep M. [5 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Sichuan, Peoples R China
[2] Aviat Ind Corp China, Chengdu Aircraft Ind Corp, Chengdu 610092, Sichuan, Peoples R China
[3] Sichuan Elect Power Co, Sichuan Elect Power Res Inst, Chengdu 610072, Sichuan, Peoples R China
[4] Univ Fed Uberlandia, Fac Elect Engn, BR-38400902 Uberlandia, MG, Brazil
[5] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
LCL-filter; grid-connected inverters; parameters design; magnetic integration; damping methods; delay; stability; impedance-based stability analysis; impedance modeling; impedance measurement; DISTRIBUTED POWER-SYSTEMS; VOLTAGE-SOURCE CONVERTERS; ACTIVE DAMPING TECHNIQUE; TIME-DELAY COMPENSATION; FILTER DESIGN; OUTPUT FILTER; OPTIMIZED DESIGN; STATIONARY FRAME; INPUT-ADMITTANCE; DIGITAL-CONTROL;
D O I
10.1109/ACCESS.2019.2935806
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL filter has been widely adopted to interface between the inverter and the grid for improving the quality of injected grid currents. However, the high-order characteristics and various constraints of the LCL filter complicate the filter design. Moreover, the stability of the internal current control loop of the individual inverter is susceptible to the inherent LCL -filter resonance peak. Meanwhile, the overall system stability would be aggravated by the external interactions between the inverter and the weak grid as well as among the paralleled inverters. Both the LCL -filter resonance peak and two types of interaction would cause severely distorted grid currents. Motivated by the existing problems, a comprehensive review on the modeling and stability analysis of the LCL -type grid-connected inverters is conducted in this paper. Concretely, the generalized parameter constraints of the LCL filter are outlined to facilitate the passive components selection, and the magnetic integration techniques of filter inductors are also introduced to reduce the weight and size of filter for increasing the power density of the system. Then, the various damping methods for enhancing the individual internal stability and the relevant application issues are also discussed. Furthermore, the impedance-based method for evaluating the system-level interactive stability is subsequently reviewed, with the emphasis on different modeling methods of inverter output impedance and online impedance measurement techniques. Finally, the future research trends on the modeling and stability analysis of LCL -type grid-connected inverters are also presented.
引用
收藏
页码:114975 / 115001
页数:27
相关论文
共 202 条
[1]   A comprehensive control system for multi-parallel grid-connected inverters with LCL filter in weak grid condition [J].
Akhavan, Ali ;
Mohammadi, Hamid Reza ;
Guerrero, Josep M. .
ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 :288-300
[2]  
[Anonymous], 1993, PERTURBATION SIGNALS
[3]  
[Anonymous], IEEE 18 WORKSH CONTR
[4]   Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters [J].
Bakhshizadeh, Mohammad Kazem ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Hjerrild, Jesper ;
Kocewiak, Lukasz ;
Bak, Claus Leth ;
Hesselbk, Bo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (10) :6792-6796
[5]   Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation [J].
Balaguer, Irvin J. ;
Lei, Qin ;
Yang, Shuitao ;
Supatti, Uthane ;
Peng, Fang Zheng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :147-157
[6]   Analysis and design of split-capacitor resistive-inductive passive damping for LCL filters in grid-connected inverters [J].
Balasubramanian, Arun Karuppaswamy ;
John, Vinod .
IET POWER ELECTRONICS, 2013, 6 (09) :1822-1832
[7]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[8]   Simple and systematic LCL filter design for three-phase grid-connected power converters [J].
Ben Said-Romdhane, M. ;
Naouar, M. W. ;
Belkhodja, I. Slama ;
Monmasson, E. .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2016, 130 :181-193
[9]   An Improved LCL Filter Design in Order to Ensure Stability without Damping and Despite Large Grid Impedance Variations [J].
Ben Said-Romdhane, Marwa ;
Naouar, Mohamed Wissem ;
Slama Belkhodja, Ilhem ;
Monmasson, Eric .
ENERGIES, 2017, 10 (03)
[10]   A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Liserre, Marco ;
Blaabjerg, Frede ;
Bak, Claus Leth .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) :54-69