Second law analysis of chemical dehumidification systems

被引:0
作者
Marletta, L [1 ]
Evola, G [1 ]
Sicurella, F [1 ]
Garozzo, R [1 ]
机构
[1] Dept Ind Engn, I-95125 Catania, Italy
来源
ENERGY FOR BUILDINGS | 2004年
关键词
dehumidification; irreversibility; exergy efficiency;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper a second law analysis is developed for two different dehumidification systems: an open-cycle absorption system based on a packed-bed tower with liquid desiccant and a dynamic adsorption system based on a desiccant silicagel wheel. The performance of both systems is also compared with a conventional HVAC. The most relevant outcome of this study is that the exergy efficiency of chemical dehumidification systems is rather low, and is lower than a conventional HVAC. This is attributable to the high temperature required by the desiccant reactivation Under the hypotesis of the present study liquid desiccant system shows a higher irreversibility production than the adsorption system.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 50 条
  • [31] CONSERVATION TECHNIQUES: ROTARY SOLID SORPTION DEHUMIDIFICATION SYSTEMS.
    Coellner, James A.
    [J]. ASHRAE Journal, 1980, 22 (04) : 42 - 44
  • [32] Exergo-economic analysis of humidification-dehumidification (HDH) desalination systems driven by heat pump (HP)
    Lawal, Dahiru U.
    Zubair, Syed M.
    Antar, Mohammad A.
    [J]. DESALINATION, 2018, 443 : 11 - 25
  • [33] The First and Second Law Analysis of Thermodynamics Analysis for Iron Ore Pellets Induration in the Traveling Grate
    Zhang Yu
    Feng Jun-xiao
    Xie Zhi-yin
    Zhang Cai
    Guo Nai-tao
    Ji Jiang-feng
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2009, 16 : 322 - 326
  • [34] Second law analysis of supercritical CO2 recompression Brayton cycle
    Sarkar, Jahar
    [J]. ENERGY, 2009, 34 (09) : 1172 - 1178
  • [35] Second law analysis of hydrogen-air combustion in a spark ignition engine
    Ismail, Saleel
    Mehta, Pramod S.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (01) : 931 - 946
  • [36] SECOND LAW ANALYSIS OF DIFFERENT REFRIGERANTS IN A TWO STAGE VAPOR COMPRESSION CYCLE
    Seyitoglu, Sertac Samed
    Kilicarslan, Ali
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2015, 35 (02) : 89 - 97
  • [37] Second-Law Analysis to Improve the Energy Efficiency of Screw Liquid Chillers
    Lee, Tzong-Shing
    [J]. ENTROPY, 2010, 12 (03): : 375 - 389
  • [38] Second law analysis in double diffusive convection through an inclined porous cavity
    Mchirgui, Ali
    Hidouri, Nejib
    Magherbi, Mourad
    Ben Brahim, Ammar
    [J]. COMPUTERS & FLUIDS, 2014, 96 : 105 - 115
  • [39] Second-law analysis and optimisation for combined Brayton and inverse Brayton cycles
    Zhang, W.
    Chen, L.
    Sun, F.
    Wu, C.
    [J]. International Journal of Ambient Energy, 2007, 28 (01): : 15 - 26
  • [40] Design recommendations for humidification-dehumidification solar water desalination systems
    Shalaby, S. M.
    Bek, M. A.
    Kabeel, A. E.
    [J]. 3RD INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT RESEARCH, ICEER 2016, 2017, 107 : 270 - 274