A 200-μW Interface for High-Resolution Eddy-Current Displacement Sensors

被引:7
|
作者
Pimenta, Matheus [1 ]
Gurleyuk, Cagri [2 ]
Walsh, Paul [1 ]
O'Keeffe, Daniel [1 ]
Babaie, Masoud [2 ]
Makinwa, Kofi A. A. [2 ]
机构
[1] Infineon Technol, Cork T12 F76C, Ireland
[2] Delft Univ Technol, Dept Microelect, NL-2628 CD Delft, Netherlands
关键词
Digitally controlled oscillator (DCO); displacement; eddy-current sensor interface; low power; phase-locked loop (PLL); PHASE NOISE;
D O I
10.1109/JSSC.2020.3044027
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a low-power eddy-current sensor interface for touch applications. It is based on a bang-bang digital phase-locked loop (DPLL) that converts the displacement of a metal target into digital information. The PLL consists of a digitally controlled oscillator (DCO) built around a sensing coil and a capacitive DAC, a comparator-based bang-bang phase/frequency detector (PFD), and a digital loop filter (DLF). The PLL locks the DCO to a reference frequency, making its digital input a direct representation of the sensing coil inductance. To compensate for the coil inductance tolerances, the DCO's center frequency can be trimmed by a second capacitive DAC. This approach obviates the need for a reference coil. When combined with a 5-mm-diameter sensing coil located 500 mu m from a metal target, the interface achieves a displacement resolution of 6.7 nm (rms) in a 3-kHz bandwidth. It consumes 200 mu W from a 1.8-V power supply, which represents the bestreported tradeoff between power consumption, bandwidth, and resolution.
引用
收藏
页码:1036 / 1045
页数:10
相关论文
共 50 条
  • [11] On the vanishing displacement current limit for eddy-current problems
    Quell, P
    Reissel, M
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1996, 76 : 649 - 650
  • [12] DISPLACEMENT EDDY-CURRENT COMPUTATION IN MAGNETIC LAMINATES
    GERI, A
    SALVINI, A
    VECA, GM
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (02) : 1075 - 1077
  • [13] High-resolution eddy current sensor system
    Schulze, Martin H.
    Heuer, Henning
    Kuettner, Martin
    SMART SENSORS, ACTUATORS, AND MEMS IV, 2009, 7362
  • [14] New Eddy-Current Sensor Setup for High-Resolution Lithium-Ion Cell Dilation Measurements
    Brauchle, Felix
    Grimsmann, Florian
    Birke, Kai Peter
    IEEE SENSORS JOURNAL, 2023, 23 (15) : 17002 - 17010
  • [15] A 0.6nm Resolution 19.8mW Eddy-Current Displacement Sensor Interface with 126MHz Excitation
    Chaturvedi, Vikram
    Nabavi, Mohammad Reza
    Vogel, Johan
    Makinwa, Kofi A. A.
    Nihtianov, Stoyan
    2017 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE (ISSCC), 2017, : 174 - 174
  • [16] Design of reliable interface system for eddy current displacement sensors in vacuum environments
    Nabavi, Mohammad Reza
    Nihtianov, Stoyan
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 2090 - 2093
  • [17] Target Temperature Effect on Eddy-Current Displacement Sensing
    Vyroubal, Darko
    Lackovic, Igor
    2015 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2015, : 305 - 309
  • [18] EXPERIMENTAL OPTIMIZATION OF THE PROBE FOR EDDY-CURRENT DISPLACEMENT TRANSDUCER
    VYROUBAL, D
    ZELE, D
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (06) : 995 - 1000
  • [19] Method for Identifying Type of Eddy-Current Displacement Sensor
    Tsutomu, Mizuno
    Sho, Goto
    Kenta, Deguchi
    Yoshinori, Kitamura
    Yuichi, Asato
    Shigemi, Enoki
    Hiroki, Shinagawa
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) : 3554 - 3557
  • [20] ENHANCED EDDY-CURRENT LOSS DUE TO DOMAIN DISPLACEMENT
    BISHOP, JEL