Determining corneal power using Pentacam after myopic photorefractive keratectomy

被引:27
作者
Falavarjani, Khalil Ghasemi [1 ]
Hashemi, Masih [1 ]
Joshaghani, Mahmoud [1 ]
Azadi, Pejvak [1 ]
Ghaempanah, Mohammad J. [1 ]
Aghai, Gholam H. [1 ]
机构
[1] Iran Univ Med Sci, Eye Res Ctr, Tehran, Iran
关键词
keratometry; keratorefractive surgery; Pentacam; Scheimpflug camera; INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; EXCIMER-LASER SURGERY; NO-HISTORY METHOD; REFRACTIVE SURGERY; CATARACT-SURGERY; EYES; KERATOTOMY;
D O I
10.1111/j.1442-9071.2010.02286.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of Pentacam Scheimpflug camera for corneal power measurement in eyes with previous photorefractive keratectomy for myopia. Methods: In this comparative interventional case series, 35 eyes of 35 patients who had myopic photorefractive keratectomy were studied. Corneal power was measured by conventional topography and Pentacam Scheimpflug camera, and equivalent keratometry readings (EKR) in different central corneal rings (0.5 to 4.5 mm), true net power and simulated keratometry (K) measurements as well as those obtained using Shammas no-history, Koch-Maloney and Haigis methods were compared with clinical history method. Results: All corneal power measurements except for the topography simulated K and true net power values were statistically similar to the clinical history values. Simulated keratometry and 4.5-mm EKR values were more closely correlated with clinical history method. Shammas formula, Pentacam simulated K and 3-, 4- and 4.5-mm EKR provided a 95% confidence interval within +/- 0.50 D of the mean clinical history method value, among these, the width of the 95% limits of agreement (LoA) was narrower for Shammas and Pentacam simulated K and 4.5-mm EKR values; however, considerably large 95% LoA were found between each of these values and those obtained with the clinical history method. Estimated preoperative keratometry was statistically similar to the preoperative measurement; however, estimated refractive change was different from actual value. Conclusions: The Pentacam 4.5-mm EKR and simulated keratometry may be used as an alternative to clinical history method to predict corneal power when pre-keratorefractive surgery data are unavailable; however, wide LoA should be considered in the calculations.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 20 条
[1]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula [J].
Borasio, Edmondo ;
Stevens, Julian ;
Smith, Guy T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2004-2014
[4]  
Feiz Vahid, 2004, Curr Opin Ophthalmol, V15, P342, DOI 10.1097/00055735-200408000-00011
[5]   Pachymetric Ratio No-History Method for Intraocular Lens Power Adjustment after Excimer Laser Refractive Surgery [J].
Geggel, Harry S. .
OPHTHALMOLOGY, 2009, 116 (06) :1057-1066
[6]   Corneal power after refractive surgery for myopia: Contact lens method [J].
Haigis, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07) :1397-1411
[7]   A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis [J].
Hamed, AH ;
Wang, L ;
Misra, M ;
Koch, DD .
OPHTHALMOLOGY, 2002, 109 (04) :651-658
[8]  
HOFFER KJ, 1995, J REFRACT SURG, V11, P490
[9]   Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery [J].
Holladay, Jack T. ;
Hill, Warren E. ;
Steinmueller, Andreas .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) :862-868
[10]  
Holladay JT, 1989, REFRACT CORNEAL SURG, V5, P203