Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla: Prediction using FEA and SED bone remodeling algorithm

被引:63
作者
Lin, Chun-Li [2 ]
Lin, Yu-Hao [2 ]
Chang, Shih-Hao [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Periodont, Gueishan Township 333, Taoyuan County, Taiwan
[2] Chang Gung Univ, Dept Mech Engn, Tao Yuan 333, Taiwan
关键词
Finite element analysis; Bone remodeling; Abutment-implant connection; Implant placement; Bone loss; FINITE-ELEMENT-ANALYSIS; MECHANICAL CHARACTERISTICS; DESIGN; BIOMECHANICS; PROSTHESES; DENTISTRY; ABUTMENTS;
D O I
10.1016/j.jbiomech.2009.10.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this study was to investigate the interactions of implant position, implant-abutment connection and loading condition influencing bone loss of an implant placed in the maxilla using finite element (FE) analysis and mathematical bone remodeling theory. The maxilla section contours were acquired using CT images to construct FE models containing RS (internal retaining-screw) and the TIS (taper integrated screwed-in) implants placed in SC (along the axis of occlusal force) and RA (along the axis of residual ridge) positions. The adaptive strain energy density (SED) algorithm was combined with FE approach to study the preliminary bone remodeling around implant systems under different load conditions. The simulated results showed that the implant position obviously influenced the bone loss. An implant placed in the RA position resulted in substantially increased bone loss. Implant receiving a lateral load slightly increased bone loss compared with an axial load. The implant type did not significantly influence bone loss. It was found that buccal site suffered the most bone loss around the implant, followed by distal, lingual and mesial sites. The implant position primarily influenced bone loss and it was found most obviously at the buccal site. Implant placed along the axial load direction of a proposed prosthesis could obtain less bone loss around the implant. Attaining proper occlusal adjustments to reduce the lateral occlusal force is recommended in implant-bone-prosthesis system. Abutments of internal engagement with or without taper-fit did not affect the bone loss in the surrounding bone. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:644 / 651
页数:8
相关论文
共 35 条
[1]   Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant -: A nonlinear finite element stress analysis [J].
Akça, K ;
Çehreli, MC ;
Iplikçioglu, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) :444-454
[2]  
Astrand P, 1999, Clin Implant Dent Relat Res, V1, P17, DOI 10.1111/j.1708-8208.1999.tb00087.x
[3]   AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - APPLICATION - A PRELIMINARY REMODELING SIMULATION [J].
BEAUPRE, GS ;
ORR, TE ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :662-670
[4]  
Benzing U R, 1995, Int J Oral Maxillofac Implants, V10, P188
[5]   Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis [J].
Bozkaya, D ;
Muftu, S ;
Muftu, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (06) :523-530
[6]   Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants [J].
Bozkaya, D ;
Müftü, S .
JOURNAL OF BIOMECHANICS, 2005, 38 (01) :87-97
[7]   Mechanics of the tapered interference fit in dental implants [J].
Bozkaya, D ;
Müftü, S .
JOURNAL OF BIOMECHANICS, 2003, 36 (11) :1649-1658
[8]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[9]   Role of mechanical environment and implant design on bone tissue differentiation:: current knowledge and future contexts [J].
Çehreli, M ;
Sahin, S ;
Akça, K .
JOURNAL OF DENTISTRY, 2004, 32 (02) :123-132
[10]   Predictions of bone remodeling around dental implant systems [J].
Chou, Hsuan-Yu ;
Jagodnik, John J. ;
Mueftue, S. .
JOURNAL OF BIOMECHANICS, 2008, 41 (06) :1365-1373