Right bundle-branch block ventricular tachycardias - Septal versus lateral ventricular origin based on activation time to the right ventricular apex

被引:8
作者
Patel, VV
Rho, RW
Gerstenfeld, EP
Hsia, HH
Callans, DJ
Marchlinski, FE
机构
[1] Univ Penn Hlth Syst, Sect Cardiac Electrophysiol, Philadelphia, PA USA
[2] Univ Penn Hlth Syst, Mol Cardiol Res Ctr, Philadelphia, PA USA
关键词
tachyarrhythmias; bundle-branch block; mapping electrophysiology;
D O I
10.1161/01.CIR.0000145542.24347.18
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Identifying the septal versus lateral site of origin of ventricular tachycardia (VT) with a right bundle-branch block (RBBB)-type pattern and an R-S ratio >1 in lead V-1 is difficult with the 12-lead ECG, especially in patients with prior apical infarction. Methods and Results-We prospectively evaluated 58 patients with VT. Sixteen patients had apical infarcts (group 1), 29 had nonapical infarcts (group 2), and 13 had no heart disease (group 3). QRS complex onset to activation at the right ventricular apex (stim-RVA) was measured during left ventricular (LV) apical septal and lateral pacing, and 47 RBBB-type VTs (QRS-RVA) were localized to the septal or lateral apex by using entrainment techniques. Pacing and VT site of origin were confirmed by electroanatomic mapping. The stim-RVA time was 59+/-16 ms for septal versus 187+/-24 ms for lateral sites in group 1, P<0.001; 70+/-14 ms for septal versus 169+/-19 ms for lateral sites in group 2, P<0.001; and 42+/-15 ms for septal versus 86+/-16 ms for lateral sites in group 3, P<0.005. The QRS-RVA time was 50+/-13 ms for apical septal VTs versus 178+/-21 ms for lateral VTs in group 1, P<0.001; 71+/-17 ms for apical septal versus 157+/-20 ms for lateral VTs in group 2, P<0.001; and 32+/-12 ms for septal versus 71+/-16 ms for lateral VTs in group 3, P<0.01. Conclusions-The QRS-RVA differs for the VT site of origin from the LV septal versus lateral apex. These data prove useful in rapidly regionalizing the VT site of origin with a V-1 R-S ratio >1, particularly in instances of an apical infarct, where surface ECG distinctions are less identifiable.
引用
收藏
页码:2582 / 2587
页数:6
相关论文
共 11 条
[1]   TIMING OF THE RIGHT VENTRICULAR APICAL ELECTROGRAM DURING SUSTAINED VENTRICULAR-TACHYCARDIA - RELATION TO SURFACE QRS MORPHOLOGY AND POTENTIAL CLINICAL IMPLICATIONS [J].
ALMENDRAL, JM ;
GROGAN, EW ;
CASSIDY, DM ;
VASSALLO, JA ;
MARCHLINSKI, FE ;
BUXTON, AE ;
DOHERTY, JU ;
JOSEPHSON, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (08) :1003-1007
[2]  
BENHAIM SA, 1996, NAT MED, V2, P13939
[3]   Efficacy of radiofrequency catheter ablation for ventricular tachycardia in healed myocardial infarction [J].
Callans, DJ ;
Zado, E ;
Sarter, BH ;
Schwartzman, D ;
Gottlieb, CD ;
Marchlinski, FE .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (04) :429-432
[4]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[5]   VENTRICULAR ACTIVATION DURING VENTRICULAR ENDOCARDIAL PACING .2. ROLE OF PACE-MAPPING TO LOCALIZE ORIGIN OF VENTRICULAR-TACHYCARDIA [J].
JOSEPHSON, ME ;
WAXMAN, HL ;
CAIN, ME ;
GARDNER, MJ ;
BUXTON, AE .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (01) :11-22
[6]   Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy [J].
Marchlinski, FE ;
Callans, DJ ;
Gottlieb, CD ;
Zado, E .
CIRCULATION, 2000, 101 (11) :1288-1296
[7]   RELATIONSHIP BETWEEN THE 12-LEAD ELECTROCARDIOGRAM DURING VENTRICULAR-TACHYCARDIA AND ENDOCARDIAL SITE OF ORIGIN IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MILLER, JM ;
MARCHLINSKI, FE ;
BUXTON, AE ;
JOSEPHSON, ME .
CIRCULATION, 1988, 77 (04) :759-766
[8]   RADIOFREQUENCY CATHETER ABLATION OF VENTRICULAR-TACHYCARDIA IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MORADY, F ;
HARVEY, M ;
KALBFLEISCH, SJ ;
ELATASSI, R ;
CALKINS, H ;
LANGBERG, JJ .
CIRCULATION, 1993, 87 (02) :363-372
[9]   Catheter ablation in patients with multiple and unstable ventricular tachycardias after myocardial infarction - Short ablation lines guided by reentry circuit isthmuses and sinus rhythm mapping [J].
Soejima, K ;
Suzuki, M ;
Maisel, WH ;
Brunckhorst, CB ;
Delacretaz, E ;
Blier, L ;
Tung, S ;
Khan, H ;
Stevenson, WG .
CIRCULATION, 2001, 104 (06) :664-669
[10]   RELATION OF PACE MAPPING QRS CONFIGURATION AND CONDUCTION DELAY TO VENTRICULAR-TACHYCARDIA REENTRY CIRCUITS IN HUMAN INFARCT SCARS [J].
STEVENSON, WG ;
SAGER, PT ;
NATTERSON, PD ;
SAXON, LA ;
MIDDLEKAUFF, HR ;
WIENER, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (02) :481-488