COMPARISON OF PADC NEUTRON DETECTORS FROM DIFFERENT SUPPLIERS

被引:6
作者
Caresana, M. [1 ]
Parravicini, A. [2 ]
Coria, S. [2 ]
Stabilini, A. [1 ,3 ]
Assenmacher, F. [3 ]
Yukihara, E. G. [3 ,4 ]
机构
[1] Politecn Milan, Dipartimento Energia, Via La Masa 34, I-20156 Milan, Italy
[2] MI AM Srl, Via De Amicis 5, Fabbiano, Italy
[3] Paul Scherrer Inst, Dept Radiat Safety & Secur, CH-5232 Villigen, Switzerland
[4] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
关键词
CR-39;
D O I
10.1093/rpd/ncx193
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to compare poly-allyl diglycol carbonate (PADC) track detectors from different suppliers for linear energy transfer (LET) spectrometry and neutron dosimetry. PADCs are commonly used for passive personal neutron dosimetry, where a common approach is to couple the PADC with a plastic radiator to generate secondary charged particles. The neutron dose can be estimated using the track density or the average LET of the secondary particles. The characterisation of PADC in terms of LET spectrometric capability and neutron sensitivity was previously performed using PADC from Intercast S.r.l., Parma, Italy, but this company stopped the production. Since it is common experience that material from different suppliers can have different properties, it became necessary to perform a comparison of PADCs from different suppliers with the Intercast material. The study permits to compare the reading procedures used at Politecnico di Milano and at the Paul Scherrer Institute.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 7 条
  • [1] Field calibration and comparison of personal neutron dosemeter designs based on CR-39 for the use around high-energy accelerators
    Boschung, A.
    Fiechtner, A.
    Mayer, S.
    Wernli, C.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1081 - 1084
  • [2] EVALUATION OF A PERSONAL AND ENVIRONMENTAL DOSEMETER BASED ON CR-39 TRACK DETECTORS IN QUASI-MONOENERGETIC NEUTRON FIELDS
    Caresana, M.
    Ferrarini, M.
    Parravicini, A.
    Naik, A. Sashala
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 100 - 103
  • [3] Determination of LET in PADC detectors through the measurement of track parameters
    Caresana, M.
    Ferrarini, M.
    Fuerstner, M.
    Mayer, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 683 : 8 - 15
  • [4] Characteristics of the Neutron Irradiation Facilities of the PSI Calibration Laboratory
    Hoedlmoser, H.
    Schuler, Ch.
    Butterweck, G.
    Mayer, S.
    [J]. APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [5] An extended study of the etching characteristics of CR-39 detectors
    Leonardi, F.
    Caresana, M.
    D'Alessandro, M.
    Mishra, R.
    Tonnarini, S.
    Trevisi, R.
    Veschetti, M.
    [J]. RADIATION MEASUREMENTS, 2009, 44 (9-10) : 787 - 790
  • [6] Formation and growth of tracks in nuclear track materials
    Nikezic, D
    Yu, KN
    [J]. MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2004, 46 (3-5) : 51 - 123
  • [7] Surface layer in CR-39 plastic track detector where the bulk etch rate is enhanced
    Yamauchi, T
    EL-Rahmany, A
    Mineyama, D
    Nakai, H
    Oda, K
    [J]. RADIATION MEASUREMENTS, 2003, 37 (02) : 119 - 125