Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor

被引:74
作者
Bokken, GCAM [1 ]
Corbee, RJ [1 ]
van Knapen, F [1 ]
Bergwerff, AA [1 ]
机构
[1] Univ Utrecht, Fac Vet Med, Dept Publ Hlth & Food Safety, NL-3508 TD Utrecht, Netherlands
关键词
food-borne infection; methodology; Salmonella; surface plasmon resonance biosensor; veterinary public health;
D O I
10.1016/S0378-1097(03)00250-7
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A surface plasmon resonance biosensor (Biacore) was used to detect Salmonella through antibodies reacting with Salmonella group A, B, D and E (Kauffmann-White typing). In the assay designed, anti-Salmonella antibodies immobilized to the biosensor surface were allowed to bind injected bacteria followed by a pulse with soluble anti-Salmonella immunoglobulins to intensify the signal. No significant interference was found for (mixtures of) 30 non-Salmonella serovars at 10(9) CFU ml(-1). A total of 53 Salmonella serovars were successfully detected at 1 x 10(7) CFU ml(-1), except those of groups C, G, L and P, as expected. The cut-off point was determined with an equicellular mixture of Salmonella enteritidis and Salmonella typhimurium at a final amount of 1.7 X 10(3) CFU per test portion. Although further work is needed to cover the detection of all relevant Salmonella serovars in food-producing animals and food products, this work demonstrates the merits of this alternative biosensor approach in terms of automation, sensitivity, specificity, simple handling and limited hands-on time. (C) 2003 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 17 条
  • [1] [Anonymous], 1984, BERGEYS MANUAL SYSTE
  • [2] DEBOER E, 1998, WARE CHEM, V28, P3
  • [3] DEWAARD R, 2002, THESIS UTRECHT U UTR
  • [4] BIOSPECIFIC INTERACTION ANALYSIS USING SURFACE-PLASMON RESONANCE DETECTION APPLIED TO KINETIC, BINDING-SITE AND CONCENTRATION ANALYSIS
    FAGERSTAM, LG
    FROSTELLKARLSSON, A
    KARLSSON, R
    PERSSON, B
    RONNBERG, I
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2): : 397 - 410
  • [5] FRATAMICO PM, 1997, 214 ACS NAT M LAS VE
  • [6] Biosensors for detection of pathogenic bacteria
    Ivnitski, D
    Abdel-Hamid, I
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (07) : 599 - 624
  • [7] Surface plasmon resonance (BIACORE) detection of serum antibodies against Salmonella enteritidis and Salmonella typhimurium
    Jongerius-Gortemaker, BGM
    Goverde, RLJ
    van Knapen, F
    Bergwerff, AA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 266 (1-2) : 33 - 44
  • [8] MANDELL GL, 2000, MANDELL DOUGLAS BENN
  • [9] Real-time analysis of antibody binding interactions with immobilized E-coli O157:H7 cells using the BIAcore
    Medina, MB
    VanHouten, L
    Cooke, PH
    Tu, SI
    [J]. BIOTECHNOLOGY TECHNIQUES, 1997, 11 (03) : 173 - 176
  • [10] Prevention of human diseases by an integrated quality control system
    Snijders, JMA
    van Knapen, F
    [J]. LIVESTOCK PRODUCTION SCIENCE, 2002, 76 (03): : 203 - 206