Space charge accumulation in two power cable grades of XLPE

被引:34
|
作者
Bambery, KR [1 ]
Fleming, RJ [1 ]
机构
[1] Monash Univ, Dept Phys, Melbourne, Vic 3004, Australia
基金
澳大利亚研究理事会;
关键词
D O I
10.1109/94.660780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accumulation of space charge in XLPE (cross-linked polyethylene), cross-linked using DCP (dicumyl peroxide) or a silane-based grafting process, was studied via the LIPP (laser-induced-pressure-pulse) technique. Planar samples 0.5 mm thick were obtained from the XLPE insulation of power distribution cables. dc fields to 10 kV/mm were applied at temperatures in the range 20 to 90 degrees C. Usually the Dcp samples developed heterocharge, and the silane samples homocharge. However, the observed space charge densities were not very different. Nearly all of the charge accumulated within 100 mu m of each electrode, with very little in the remainder of the volume. Both sample types showed a near-perfect inversion of the equilibrium space charge profiles on reversing the applied voltage polarity. This observation is explained in terms of charge injection at the electrodes, electron transfer between electrode and XLPE in either direction involving the same narrow 'window' of combined donor and acceptor states in the insulator, centered on the Fermi level.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 50 条
  • [1] Space charge accumulation in power cable XLPE insulation
    Department of Physics, Monash University, Clayton, Vic., Australia
    不详
    IEEE Trans Dielectr Electr Insul, 3 (273-281):
  • [2] Space charge accumulation in power cable XLPE insulation
    Lim, FN
    Fleming, RJ
    Naybour, RD
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (03) : 273 - 281
  • [3] Influence of thermal treatment and residues on space charge accumulation in XLPE for DC power cable application
    Fu, M.
    Chen, G.
    Dissado, L. A.
    Fothergill, J. C.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) : 53 - 64
  • [4] Effect of Charge Rate on Space Charges Accumulation in XLPE in Damped Alternating Current Testing for Power Cable
    Wang W.
    Jiang D.
    Dong W.
    Tian Y.
    Xiong J.
    Du G.
    Wang, Wei (kingway@ncepu.edu.cn), 2018, Science Press (44): : 2881 - 2888
  • [5] Analysis of Influence Factors on Space Charge Accumulation Characteristics of 320 kV XLPE Cable
    Liu, Yuqi
    Cai, Xinjing
    Cai, Shikai
    POLYMER SCIENCE SERIES A, 2022, 64 (05) : 415 - 423
  • [6] Analysis of Influence Factors on Space Charge Accumulation Characteristics of 320 kV XLPE Cable
    Xinjing Yuqi Liu
    Shikai Cai
    Polymer Science, Series A, 2022, 64 : 415 - 423
  • [7] The space charge characteristics of XLPE cable peelings under power frequency voltage
    Song, Pengxian
    Meng, Fansong
    Liu, Jiping
    Wang, Haoming
    Zhu, Mingzheng
    Li, Xu
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 130 - 133
  • [8] The effect of humidity on space charge accumulation in XLPE
    Montanari, GC
    Palmièri, F
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 205 - 208
  • [9] The development of DC+/-500kV XLPE cable in consideration of the space charge accumulation
    Yamanaka, T
    Maruyama, S
    Tanaka, T
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 689 - 694
  • [10] The influence of electrodes and conditioning on space charge accumulation in XLPE
    Fleming, RJ
    Henriksen, M
    Holboll, JT
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2000, 7 (04) : 561 - 571