Modeling and calibration of pointing errors with alt-az telescope

被引:24
作者
Huang, Long [1 ,2 ]
Ma, Wenli [1 ]
Huang, Jinlong [1 ]
机构
[1] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
Pointing error; Alt-az telescope; Error analysis; SPRM; COMPENSATION;
D O I
10.1016/j.newast.2016.02.007
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
This paper presents a new model for improving the pointing accuracy of a telescope. The Denavit-Hartenberg (D-H) convention was used to perform an error analysis of the telescope's kinematics. A kinematic model was used to relate pointing errors to mechanical errors and the parameters of the kinematic model were estimated with a statistical model fit using data from two large astronomical telescopes. The model illustrates the geometric errors caused by imprecision in manufacturing and assembly processes and their effects on the pointing accuracy of the telescope. A kinematic model relates pointing error to axis position when certain geometric errors are assumed to be present in a telescope. In the parameter estimation portion, the semi-parametric regression model was introduced to compensate for remaining nonlinear errors. The experimental results indicate that the proposed semi-parametric regression model eliminates both geometric and nonlinear errors, and that the telescope's pointing accuracy significantly improves after this calibration. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 22 条
[1]  
Antonio J.-N., 2012, OPT EXPRESS, V20, P12550
[2]  
Chen Z.L., 2009, J CHINA U POSTS TELE, V16, pS20
[3]   SMOOTHING NOISY DATA WITH SPLINE FUNCTIONS [J].
WAHBA, G .
NUMERISCHE MATHEMATIK, 1975, 24 (05) :383-393
[4]   Using stars to determine the absolute pointing of the fluorescence detector telescopes of the Pierre Auger Observatory [J].
De Donato, Cinzia ;
Prouza, Michael ;
Sanchez, Federico ;
Santander, Marcos ;
Camin, Daniel ;
Garcia, Beatriz ;
Grassi, Valerio ;
Grygar, Jiri ;
Hrabovsky, Miroslav ;
Ridky, Jan ;
Schovanek, Petr ;
Travnicek, Petr .
ASTROPARTICLE PHYSICS, 2007, 28 (02) :216-231
[5]  
Denavit J., 1955, Trans. ASME, V22, P215, DOI DOI 10.1115/1.4011045
[6]   SEMIPARAMETRIC ESTIMATES OF THE RELATION BETWEEN WEATHER AND ELECTRICITY SALES [J].
ENGLE, RF ;
GRANGER, CWJ ;
RICE, J ;
WEISS, A .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1986, 81 (394) :310-320
[7]  
Everett L.J., 1993, ROBOT CALIBRATION
[8]  
Green P., 1994, MONOGRAPH STAT APPL, V58
[9]  
Hardie Wolfgang., 1991, Smoothing Techniques with Implementation in S
[10]   Modeling and calibration of pointing errors using a semi-parametric regression method with applications in inertially stabilized platforms [J].
Hong, Huajie ;
Zhou, Xiaoyao ;
Zhang, Zhiyong ;
Fan, Dapeng .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2013, 227 (10) :1492-1503