INDIAN JOURNAL OF NUCLEAR MEDICINE
|
2022年
/
37卷
/
01期
关键词:
Bone scan;
kit fractionation;
MDP;
radiopharmaceutical;
sterility;
COST;
D O I:
10.4103/ijnm.ijnm_115_21
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: Tc-99m Methylene diphosphonate (MDP) is prepared in house by labeling MDP cold kit. Each kit is a single time use vial and contains large amounts of reagent sufficient for preparing multiple doses. Therefore, several centers are adopting the practice of fractionating the MDP kit so that it can be used multiple times. The aim of the study was to evaluate the effect of kit fractionation on radiopharmaceutical property. Materials and Methods: The MDP kit was fractionated using two different approaches, namely, vial and syringe method. The quality of Tc-99m MDP prepared using these approaches was assessed and compared with that prepared by the conventional method. The image quality was evaluated in a total of 100 patients. Results: The vial and syringe fractionated Tc-99m MDP showed > 95% RCP till the 4th and 2nd days of fractionation, respectively. Percentage radiochemical purity deteriorated to 83.6% and 88% on the 8th day of fractionation in the vial and syringe method, respectively. No microbial growth was observed in any of these methods till the 8th day of fractionation. The reconstituted MDP solution during all preparations was clear and colorless in appearance with pH ranging from 6.5 to 7.5. The image contrast, contrast-to-noise, and signal-to-noise ratio were statistically similar in both methods compared to the conventional method until the 2nd day of fractionation. The image quality data showed no statistical difference among images of vial and syringe fractionated MDP as compared to the conventional unfractionated Tc-99m MDP. Conclusions: The observations revealed that if fractionated with utmost care, both methods yield almost similar results.
机构:
Oakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USAOakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA
Jolepalem, Prashant
Yeow, Raymond Y.
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ, William Beaumont Sch Med & Hlth Syst, Sch Med, Royal Oak, MI USAOakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA
Yeow, Raymond Y.
Cosner, Diane
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Pathol, Royal Oak, MI USAOakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA
Cosner, Diane
Seitz, John P.
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USAOakland Univ, William Beaumont Sch Med & Hlth Syst, Dept Diagnost Radiol & Mol Imaging, Royal Oak, MI USA