Measurement of the axial eye length by wavelength tuning interferometry

被引:2
|
作者
Lexer, F
Hitzenberger, CK
Kulhavy, M
Fercher, AF
机构
关键词
D O I
10.1117/12.260873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternative approach to measure intraocular optical distances in vivo is wavelength tuning interferometry. The principle of this technique is that every wavelength shift of a laser diode is associated with a phase shift of the waves reflected at the cornea and the retina. This results in a change of the interference order of the fringe system that will occur when the two wavefronts interfere. By Fourier transform of the intensity data, we cannot only measure the axial eye length but also other intraocular distances. In our approach we used an external cavity, single mode laser diode at a center wavelength of 780 nm which is tunable over 15 nm. First measurements were carried out in a model eye using the mode hop free tuning range of 9 nm, at the maximum tuning rate of 0.33 nm/s. The precision we obtained for the axial eye length was 0.04 mm. The large tuning range cannot be used for in vivo measurements because of the slow scanning rate of 0.33 nm/s. With this scanning rate the signal frequency corresponding to the axial eye length is on the order of 30 Hz. This is within the frequency range of the intensity modulations caused by fundus pulsations due to the heart beat and can therefore not be separated from them. The in vivo measurements have to be performed by tuning the wavelength of the laser with a piezoelectric transducer to achieve signal frequencies in the kHz range. Since the tuning range in this case is only 0.18 nm the resolution is about 50 times worse than that achieved in the model eye.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 50 条
  • [41] Surface measurement of indium tin oxide thin film by wavelength-tuning Fizeau interferometry
    Kim, Yangjin
    Hibino, Kenichi
    Sugita, Naohiko
    Mitsuishi, Mamoru
    APPLIED OPTICS, 2015, 54 (23) : 7135 - 7141
  • [42] Full-field phase measurement by wavelength-tuning interferometry in the C-band
    Egan, Patrick
    Lakestani, Fereydoun
    Whelan, Maurice P.
    Connelly, Michael J.
    OPTICAL ENGINEERING, 2006, 45 (12)
  • [43] Interferometric precision measurement of highly reflective thin film using wavelength tuning Fizeau interferometry
    Kim, Yangjin
    Hibino, Kenichi
    Mitsuishi, Mamoru
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE VI, 2019, 11032
  • [44] Assessing IOLMaster Measurement of Eye Axial Length in Pathologic Myopia Patients with Staphyloma
    Leong, Jamie
    Silverman, Ronald
    Chang, Stanley
    Quan Hoang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [45] Simultaneous measurement of objective refraction, accommodation response and axial length of the human eye
    Alderson, Alison
    Mankowska, Aleksandra
    Cufflin, Matthew P.
    Mallen, Edward A. H.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (01) : 100 - 108
  • [46] Wavelength-tuning interferometry with suppression of dispersive error
    Kim, Sungtae
    Kim, Yangjin
    Hibino, Kenichi
    Sugita, Naohiko
    Mitsuishi, Mamoru
    OPTIK, 2021, 247
  • [47] Axial Length Measurement Using Partial Coherence Interferometry in Myopic Children: Repeatability of the Measurement and Comparison with Refractive Components
    Shuhei Kimura
    Satoshi Hasebe
    Manabu Miyata
    Ichiro Hamasaki
    Hiroshi Ohtsuki
    Japanese Journal of Ophthalmology, 2007, 51 : 105 - 110
  • [48] Axial length measurement using partial coherence interferometry in myopic children: Repeatability of the measurement and comparison with refractive components
    Kimura, Shuhei
    Hasebe, Satoshi
    Miyata, Manabu
    Hamasaki, Ichiro
    Ohtsuki, Hiroshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (02) : 105 - 110
  • [49] SAGITTAL GROWTH OF EYE .4. ULTRASONIC MEASUREMENT OF AXIAL LENGTH OF EYE FROM BIRTH TO PUBERTY
    LARSEN, JS
    ACTA OPHTHALMOLOGICA, 1971, 49 (06): : 873 - &
  • [50] Comparison of Partial Interferometry and Ultrasound A-scan for Axial Length Measurement in Retinal Vein Occlusions
    Sung, Jae Yun
    Heo, Dong Won
    Jo, Young Joon
    Kim, Jung Yeul
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (08): : 1228 - 1232