Measurement of the axial eye length by wavelength tuning interferometry

被引:2
|
作者
Lexer, F
Hitzenberger, CK
Kulhavy, M
Fercher, AF
机构
关键词
D O I
10.1117/12.260873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternative approach to measure intraocular optical distances in vivo is wavelength tuning interferometry. The principle of this technique is that every wavelength shift of a laser diode is associated with a phase shift of the waves reflected at the cornea and the retina. This results in a change of the interference order of the fringe system that will occur when the two wavefronts interfere. By Fourier transform of the intensity data, we cannot only measure the axial eye length but also other intraocular distances. In our approach we used an external cavity, single mode laser diode at a center wavelength of 780 nm which is tunable over 15 nm. First measurements were carried out in a model eye using the mode hop free tuning range of 9 nm, at the maximum tuning rate of 0.33 nm/s. The precision we obtained for the axial eye length was 0.04 mm. The large tuning range cannot be used for in vivo measurements because of the slow scanning rate of 0.33 nm/s. With this scanning rate the signal frequency corresponding to the axial eye length is on the order of 30 Hz. This is within the frequency range of the intensity modulations caused by fundus pulsations due to the heart beat and can therefore not be separated from them. The in vivo measurements have to be performed by tuning the wavelength of the laser with a piezoelectric transducer to achieve signal frequencies in the kHz range. Since the tuning range in this case is only 0.18 nm the resolution is about 50 times worse than that achieved in the model eye.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 50 条
  • [31] Measurement of optical thickness variation of BK7 plate by wavelength tuning interferometry
    Kim, Yangjin
    Hibino, Kenichi
    Sugita, Naohiko
    Mitsuishi, Mamoru
    OPTICS EXPRESS, 2015, 23 (17): : 22928 - 22938
  • [32] Measurement of absolute optical thickness distribution of a mask-glass by wavelength tuning interferometry
    Hibino, Kenichi
    Yangjin, Kim
    Bitou, Youichi
    Ohsawa, Sonko
    Sugita, Naohiko
    Mitsuishi, Mamoru
    INTERFEROMETRY XIV: TECHNIQUES AND ANALYSIS, 2008, 7063
  • [33] In vivo intraocular ranging by wavelength tuning interferometry
    Hitzenberger, CK
    Kulhavy, M
    Lexer, F
    Baumgartner, A
    Fercher, AF
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS II, PROCEEDINGS OF, 1998, 3251 : 47 - 51
  • [34] A phase extraction algorithm in wavelength tuning interferometry
    Liu, Jian
    Tian, Ailing
    Liu, Bingcai
    Wang, Hongjun
    Tian, A. (tian21964@sohu.com), 1600, Chinese Optical Society (34):
  • [35] Wavelength-tuning interferometry of intraocular distances
    Lexer, F
    Hitzenberger, CK
    Fercher, AF
    Kulhavy, M
    APPLIED OPTICS, 1997, 36 (25): : 6548 - 6553
  • [36] Comparison of eye length measurement using partial coherence interferometry and clinical ultrasound
    Greenberg, KP
    Francis, EL
    Allam, A
    Desai, A
    Ying, GS
    Stone, RA
    Quinn, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U287 - U287
  • [37] Accuracy of partial coherence interferometry in patients with large inter-eye axial length difference
    Petersen, Christine Ann
    Taravati, Parisa
    Chen, Philip P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [38] Comparison of Eye Axial Length Measurements Taken Using Partial Coherence Interferometry and OCT Biometry
    Rizzieri, Nicola
    Facchin, Alessio
    VISION, 2024, 8 (03)
  • [39] Accuracy of partial coherence interferometry in patients with large inter-eye axial length difference
    Petersen, Christine A.
    Terveen, Daniel C.
    Quist, Tyler
    Taravati, Parisa
    Ding, Leona
    Oetting, Thomas A.
    Chen, Philip P.
    PLOS ONE, 2021, 16 (02):
  • [40] Axial Length Measurement in Asteroid Hyalosis: Comparing Laser Interferometry and Ultrasound A-scan
    Moghimi, Sasan
    Kiumehr, Saman
    Amoozadeh, Javad
    Fakhraie, Ghasem
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2009, 21 (01): : 29 - 34