Measurement of the axial eye length by wavelength tuning interferometry

被引:2
|
作者
Lexer, F
Hitzenberger, CK
Kulhavy, M
Fercher, AF
机构
关键词
D O I
10.1117/12.260873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternative approach to measure intraocular optical distances in vivo is wavelength tuning interferometry. The principle of this technique is that every wavelength shift of a laser diode is associated with a phase shift of the waves reflected at the cornea and the retina. This results in a change of the interference order of the fringe system that will occur when the two wavefronts interfere. By Fourier transform of the intensity data, we cannot only measure the axial eye length but also other intraocular distances. In our approach we used an external cavity, single mode laser diode at a center wavelength of 780 nm which is tunable over 15 nm. First measurements were carried out in a model eye using the mode hop free tuning range of 9 nm, at the maximum tuning rate of 0.33 nm/s. The precision we obtained for the axial eye length was 0.04 mm. The large tuning range cannot be used for in vivo measurements because of the slow scanning rate of 0.33 nm/s. With this scanning rate the signal frequency corresponding to the axial eye length is on the order of 30 Hz. This is within the frequency range of the intensity modulations caused by fundus pulsations due to the heart beat and can therefore not be separated from them. The in vivo measurements have to be performed by tuning the wavelength of the laser with a piezoelectric transducer to achieve signal frequencies in the kHz range. Since the tuning range in this case is only 0.18 nm the resolution is about 50 times worse than that achieved in the model eye.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 50 条
  • [1] AXIAL EYE-LENGTH MEASUREMENT BY WAVELENGTH-SHIFT INTERFEROMETRY
    SEKINE, A
    MINEGISHI, I
    KOIZUMI, H
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07): : 1651 - 1655
  • [3] Axial Eye Length Measurement System Based on Low Coherence Interferometry
    Wang Cheng
    Zhou Qi
    Chen Yijun
    Chen Minghui
    Xiang Huazhong
    Zheng Gang
    Zhao Jie
    Zhang Dawei
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (05):
  • [4] Measurement of axial length using laser interferometry in a model eye.
    Goyal, R
    Rakebrandt, F
    Turner, JM
    North, RV
    Morgan, JE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S55 - S55
  • [5] Axial Eye Length Measurement System Based on Low Coherence Interferometry
    Wang C.
    Zhou Q.
    Chen Y.
    Chen M.
    Xiang H.
    Zheng G.
    Zhao J.
    Zhang D.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2022, 49 (05):
  • [6] Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry
    Kim, Jae-Hyung
    Moon, Tae Hwan
    Chae, Ju Byung
    Hyung, Sungmin
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2014, 18 (05) : 546 - 550
  • [7] Application of diffractive optics for axial eye length measurement using partial coherence interferometry
    Moller, B
    Rudolph, G
    Klopffleisch, A
    Donnerhacke, KH
    Dorsel, A
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 175 - 182
  • [8] Transpalpebral measurement of axial eye length
    Martius, P.
    Tech, S.
    Stachs, O.
    Guthoff, R. F.
    OPHTHALMOLOGE, 2010, 107 (08): : 733 - 739
  • [9] Interferometric measurement of the axial length of the eye
    Hård, S
    Fuxin, PO
    Gerhardsson, D
    Torstensson, PA
    Nilsson, T
    Sjöstrand, J
    MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF, 1999, 3564 : 179 - 181
  • [10] Interferometric measurement of the axial length of the eye
    Hard, Sverker
    Fuxin, Per-Ola
    Gerhardsson, Dan
    Torstensson, Per-Arne
    Nilsson, Tomas
    Sjostrand, Johan
    Proceedings of SPIE - The International Society for Optical Engineering, 3564 : 179 - 181