Modeling and Control of an Integrated Wind Power Generation and Energy Storage System

被引:0
作者
Jiang, Zhenhua [1 ]
Yu, Xunwei [1 ]
机构
[1] Univ Miami, Dept Elect & Comp Engn, Coral Gables, FL 33146 USA
来源
2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8 | 2009年
关键词
Integrated energy system; wind turbine; doubly fed induction generator; energy storage; power converters; battery; FED INDUCTION GENERATOR; MACHINE; DFIG;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind energy is gaining the most interest among a variety of renewable energy resources, but the disadvantage is that wind power generation is intermittent, depending on weather conditions. Energy storage is necessary to get a smooth output from a wind turbine. This paper presents a new integrated power generation and energy storage system for doubly-fed induction generator based wind turbine systems. A battery energy storage system is connected to the DC link of the back-to-back power converters of the doubly-fed induction generator through a bi-directional DC/DC power converter. The energy storage device is controlled so as to smooth out the total output power as the wind speed varies. Control algorithms are developed for the grid-side converter, rotor-side converter and battery converter, and are tested on a simulation model developed in MATLAB/Simulink. The model contains a DFIG wind turbine, three PWM power converters and associated controllers, a DC-link capacitor, a battery, and an equivalent power grid. Simulation studies are carried out on a 2MW DFIG wind turbine and the results suggest that the integrated power generation and energy storage system can supply steady output power as the wind speed changes.
引用
收藏
页码:2612 / 2619
页数:8
相关论文
共 18 条
[1]   Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system [J].
Akagi, H ;
Sato, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (01) :109-116
[2]  
Akhmatov V., 2003, THESIS TU DENMARK KG
[3]  
[Anonymous], 2000, VECTOR CONTROL DYNAM
[4]  
Chahwan G., 2007, P POWER CONVERSION C, P1201
[5]   Energy Storage Systems in Distributed Generation Schemes [J].
Choi, S. S. ;
Tseng, K. J. ;
Vilathgamuwa, D. M. ;
Nguyen, T. D. .
2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, :485-492
[6]   Variable-speed wind power generation using doubly fed wound rotor induction machine - A comparison with alternative schemes [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (03) :414-421
[7]   A power system stabilizer for DFIG-based wind generation [J].
Hughes, FM ;
Anaya-Lara, O ;
Jenkins, N ;
Strbac, G .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (02) :763-772
[8]   Modeling of the wind turbine with a doubly fed induction generator for grid integration studies [J].
Lei, YZ ;
Mullane, A ;
Lightbody, G ;
Yacamini, R .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :257-264
[9]  
Mohan Ned., 2001, ADV ELECT DRIVES ANA
[10]   Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip [J].
Morren, J ;
de Haan, SWH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :435-441