Effect of Hydroxocobalamin on Surface Oximetry in Nonexposed Humans

被引:3
作者
Cashin, Brian V., Jr. [1 ]
Matlock, Aaron G. [1 ]
Kang, Chris [1 ]
Reynolds, Penny S. [2 ]
Wills, Brandon K. [2 ,3 ]
机构
[1] Madigan Army Med Ctr, Dept Emergency Med, Tacoma, WA 98431 USA
[2] VCU Med Ctr, Dept Emergency Med, Richmond, VA 23219 USA
[3] Virginia Poison Ctr, Richmond, VA USA
关键词
co-oximetry; cyanide; hydroxocobalamin;
D O I
10.1017/S1049023X13003518
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The newer cyanide antidote, hydroxocobalamin, due to its pigmentation, has been found to cause interferences in some laboratory assays. Co-oximetry may also be affected by hydroxocobalamin, leading to false elevations in hemoglobin concentration, methemoglobin, carboxyhemoglobin, and false decreases in oxyhemoglobin. The Masimo Radical-7 is a medical device that performs noninvasive oximetry and estimates hemoglobin (Hb) concentration and percent carboxyhemoglobin (COHb), methemoglobin (MetHb), and oxyhemoglobin saturation (O(2)Hb). Study Objectives: The study sought to determine the effect of hydroxocobalamin on noninvasive measurement of hemoglobin indices using the Masimo Radical-7 monitor. Methods: Seven asymptomatic volunteers who were unexposed to cyanide had baseline heart rate (HR), blood pressure (BP), and oximeter measurements recorded followed by an infusion of five grams of hydroxocobalamin over 15 minutes. The above parameters were subsequently recorded at: 5, 10, 15, 30 and 60 minutes post infusion. Data were analyzed by calculating the area under the curve (AUC) for each variable and comparing the results to expected values by paired t tests. Expected AUC values were calculated by extrapolating baseline values across the entire time period. Results: The mean differences from baseline values with 95% confidence intervals and t tests of mean difference were: SBP: 11 mm Hg (95% CI, 0-22; P = .051); HR: -9 (95% CI, -15 to -3; P = .01); Hb: -0.1 (95% CI, -0.7 to 0.4; P = .57); O 2 Hb: 0 g/dL (95% CI, -1 to 1; P = .41); COHb: -1 (95% CI, -3 to 1; P = .25); MetHb: -0.2 (95% CI, -0.3 to 0; P = .03). Discussion: After infusion of hydroxocobalamin there was a significant elevation of systolic blood pressure and decrease in heart rate. There were no significant differences in Hb, O(2)Hb, and COHb. Although percent methemoglobin concentrations were statistically lower, the authors feel this difference is of trivial clinical significance. Conclusion: The administration of hydroxocobalamin does not significantly impact noninvasive oximetry.
引用
收藏
页码:367 / 369
页数:3
相关论文
共 9 条
[1]  
[Anonymous], 2007, CYAN PACK INS
[2]  
BEAUDEUX JL, 1994, CLIN CHEM, V40, P2120
[3]   Prospective study of hydroxocobalamin for acute cyanide poisoning in smoke inhalation [J].
Borron, Stephen W. ;
Baud, Frederic J. ;
Barriot, Patrick ;
Imbert, Michel ;
Bismuth, Chantal .
ANNALS OF EMERGENCY MEDICINE, 2007, 49 (06) :794-801
[4]   EFFECT OF THE CYANIDE ANTIDOTE HYDROXOCOBALAMIN ON COMMONLY ORDERED SERUM CHEMISTRY STUDIES [J].
CURRY, SC ;
CONNOR, DA ;
RASCHKE, RA .
ANNALS OF EMERGENCY MEDICINE, 1994, 24 (01) :65-67
[5]   Hydroxocobalamin for acute cyanide poisoning: New data from preclinical and clinical studies; New results from the prehospital emergency setting [J].
Dart, Richard C. .
CLINICAL TOXICOLOGY, 2006, 44 :1-3
[6]   Spectrophotometry of hydroxocobalamin and hemoglobin reveals production of an unanticipated methemoglobin variant [J].
Denninghoff, Kurt ;
Walter, Frank Gardner ;
Langa, A. J. ;
He, Yao ;
Chipman, Russell A. .
CLINICAL TOXICOLOGY, 2008, 46 (06) :545-550
[7]   Prehospital administration of hydroxocobalamin for smoke inhalation-associated cyanide poisoning: 8 years of experience in the Paris Fire Brigade [J].
Fortin, Jean-Luc ;
Giocanti, Jean-Pascal ;
Ruttimann, Michel ;
Kowalski, Jean-Jacques .
CLINICAL TOXICOLOGY, 2006, 44 :37-44
[8]   Potential interference by hydroxocobalamin on cooximetry hemoglobin measurements during cyanide and smoke inhalation treatments [J].
Lee, Jangwoen ;
Mukai, David ;
Kreuter, Kelly ;
Mahon, Sari ;
Tromberg, Bruce ;
Brenner, Matthew .
ANNALS OF EMERGENCY MEDICINE, 2007, 49 (06) :802-805
[9]  
Vest P, 2002, ANN BIOL CLIN-PARIS, V60, P57