Simultaneous determination of phenol, methylphenols, chlorophenols and bisphenol-A by headspace solid-phase microextraction-gas chromatography-mass spectrometry in water samples and industrial effluents

被引:36
作者
Limam, Intissar [1 ,2 ]
Guenne, Angeline [1 ]
Driss, Mohamed Ridha [2 ]
Mazeas, Laurent [1 ]
机构
[1] Cemagref, UR HBAN, F-92163 Antony, France
[2] Fac Sci Bizerte, Unite Rech Chim Analyt Appl 05 UR 12 03, Jarzouna 7021, Tunisia
关键词
headspace solid-phase microextraction; gas chromatography-mass spectrometry; phenol; chlorophenols; bisphenol-A; derivatisation; LIQUID-CHROMATOGRAPHY; DIGLYCIDYL ETHER; FOOD CANS; DERIVATIZATION; EXTRACTION; ALKYLPHENOLS; MATRICES; LACQUER;
D O I
10.1080/03067310903267307
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) automatic method for simultaneous determination of trace amounts of phenol, methylphenols (MPs), chlorophenols (CPs) and bisphenol-A (BPA) in water samples and industrial effluents has been developed. Prior to SPME extraction, a direct derivatisation step using acetic anhydride was performed. Four different SPME fibre coatings (75 mu m CAR-PDMS, 65 mu m PDMS-DVB, 100 mu m PDMS and 85 mu m PA) were tested. The parameters affecting the HS-SPME process and derivatisation step studied were: extraction time (5-60 min) and temperature (40-100 degrees C), derivatisation time (5-10 min), sample agitation (0-500 rpm), addition of sodium chloride (0-40%). The GC-MS quantification was performed by internal standard calibration and the limits of detection (LODs) were in the low ng L-1. The proposed analytical procedure provided a good linearity (r(2) > 0.9931) for standard solutions and a repeatability ranging from 4.8 to 15.2% (n = 5). The obtained results show that the developed method was rapid, simple and efficient for phenol, MPs, CPs and BPA analysis, and provides a good alternative to SPE and LLE. Finally, the proposed method has been applied successfully to analyse water samples, municipal solid waste landfill and industrial effluents.
引用
收藏
页码:230 / 244
页数:15
相关论文
共 33 条
[1]   CHEMICAL-STRUCTURE, SALMONELLA MUTAGENICITY AND EXTENT OF CARCINOGENICITY AS INDICATORS OF GENOTOXIC CARCINOGENESIS AMONG 222 CHEMICALS TESTED IN RODENTS BY THE UNITED-STATES NCI/NTP [J].
ASHBY, J ;
TENNANT, RW .
MUTATION RESEARCH, 1988, 204 (01) :17-115
[2]   Analysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry [J].
Basheer, C ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) :163-169
[3]  
BROTONS JA, 1995, ENVIRON HEALTH PERSP, V103, P608, DOI 10.2307/3432439
[4]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[5]   Evaluation of solid-phase microextraction conditions for the determination of chlorophenols in honey samples using gas chromatography [J].
Campillo, Natalia ;
Penalver, Rosa ;
Hernandez-Cordoba, Manuel .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (01) :31-37
[6]  
Cao XL, 2008, J AOAC INT, V91, P622
[7]   Determining leaching of bisphenol A from plastic containers by solid-phase microextraction and gas chromatography-mass spectrometry [J].
Chang, CM ;
Chou, CC ;
Lee, MR .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :41-47
[8]   Pentachlorophenol removal from aqueous matrices by sorption with almond shell residues [J].
Estevinho, B. N. ;
Ratola, N. ;
Alves, A. ;
Santos, L. .
JOURNAL OF HAZARDOUS MATERIALS, 2006, 137 (02) :1175-1181
[9]   Solid-phase microextraction coupled to liquid chromatography for the analysis of phenolic compounds in water [J].
González-Toledo, E ;
Prat, MD ;
Alpendurada, MF .
JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) :45-52
[10]  
Harvey D., 2000, MODERN ANAL CHEM, V1st, P95