关键词
Three-dimensional conformal radiotherapy; (3DCRT); Intensity modulated radiotherapy (IMRT); Second cancer risk; Prostate cancer; Organ equivalent dose (OED); Excess absolute risk (EAR); RADIATION-THERAPY; CALCULATED RISK; 2ND CANCERS; IMRT; MALIGNANCIES; BRACHYTHERAPY; TOXICITY; RAPIDARC; 3D-CRT; VMAT;
D O I
10.1016/j.jrras.2021.11.002
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Secondary cancer resulting from radiation exposure to normal tissues is always a concern. Thus, present study aimed to estimate this risk for patient receiving radiotherapy using advanced techniques like Intensity-modulated radiation therapy (IMRT) and Three-dimensional conformal radiotherapy (3DCRT). Ten prostate cancer cases were chosen, and CT images were acquired for each patient. 3DCRT and IMRT plans were generated and were compared with respect to several dosimetric parameters for Planning Target Volume (PTV) and for Organs at Risk (OARs). The second cancer risks were estimated by Excess absolute risk (EAR) for OARs. For prostate, the PTV dose coverage parameters were significantly improved in IMRT compared to 3DCRT. The rectum and bladder mean dose DMean, V50Gy, and V40Gy were significantly decreased with IMRT in comparison to 3DCRT. The maximum dose (DMax), DMean, V30Gy, and V20Gy for head of femurs significantly decreased with IMRT plans. However, the colon DMean significantly increased with IMRT compared with 3DCRT plans. Compared with the 3DCRT the IMRT plans decreased the organ equivalent dose (OED) in rectum based on the linear, plateau and linear-exponential models. The OED for the bladder also decreased with linear model in IMRT plan. While, the OED for the colon significantly increased in IMRT. The IMRT plans were decreased second cancer risk for the rectum by 10%, 26.6% and 19.5% for linear, plateau and linear-exponential dose-response models respectively. The bladder second cancer risk was decreased by 14% with linear dose-response model in comparison to 3DCRT plans. However, the second cancer risk for colon was significantly increased in average by 91.2% with IMRT plans. IMRT technique demonstrated a clear advantage in dose coverage, conformity, and homogeneity over 3DCRT and was superior in terms of OAR-sparing. The Second cancer risk for in field organs (rectum and bladder) was decreased with IMRT compared to 3DCRT plan.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [1] Assessment of the Second Cancer Risk after Prostate Cancer Treatment: Comparison of 3D Conformal Radiotherapy and Intensity Modulated Radiotherapy
    Hassana I.M.
    Attalla E.M.
    El-Gohary M.I.
    Iranian Journal of Medical Physics, 2022, 19 (04) : 222 - 233
  • [2] Whole pelvic radiotherapy for prostate cancer using 3D conformal and intensity-modulated radiotherapy
    Ashman, JB
    Zelefsky, MJ
    Hunt, MS
    Leibel, SA
    Fuks, Z
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (03): : 765 - 771
  • [3] Comparison of intensity modulated radiotherapy and 3D conformal radiotherapy in patients with cancer of anal canal
    Mihaylova, I.
    Gesheva, N.
    Parvanova, V.
    Chakarova, A.
    Dimitrova, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S79 - S79
  • [4] Urinary tract infections in patients with early prostate cancer during 3D conformal radiotherapy
    Tunio, Mutahir Ali
    Hussain, Altaf
    Rafi, Mansoor
    RAWAL MEDICAL JOURNAL, 2009, 34 (02):
  • [5] A comparison of intensity-modulated radiotherapy versus 3D conformal radiotherapy for prostate cancer patients whose rectal reaction to prior conventional radiotherapy was known
    Ozard, S
    Parker, W
    Patrocinio, H
    Faria, S
    Souhami, L
    MEDICAL PHYSICS, 2005, 32 (07) : 2410 - 2410
  • [6] Patterns of Care and Outcomes of Intensity-Modulated Radiotherapy and 3D Conformal Radiotherapy for Early Stage Glottic Cancer: A National Cancer Database Analysis
    Korpics, Mark C.
    Turchan, W. Tyler
    Rooney, Michael K.
    Koshy, Matthew
    Spiotto, Michael T.
    CANCERS, 2019, 11 (12)
  • [7] Comparison of conventional conformal (3D) and intensity modulated (IMRT) postoperative radiotherapy for gastric cancer
    Zaucha, R.
    Szewczyk, P.
    Jassem, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S185 - S186
  • [8] Comparison of 3D conformal and intensity modulated radiotherapy in early stage oral tongue cancer: dosimetric and radiobiological evaluation
    Shanei, A.
    Abedi, I.
    Saadatmand, P.
    Amouheidari, A. R.
    Akbari-Zadeh, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (01): : 33 - 42
  • [9] A comparison of dose to the penile bulb between 3D conformal radiotherapy and intensity-modulated radiation therapy for prostate cancer
    Valinta, D
    Labib, A
    Breton-Callu, C
    Dejean, C
    Poinsignon, A
    Floiras, J
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S337 - S337
  • [10] Comparative Effectiveness of Intensity Modulated (IMRT) versus 3D Conformal (CRT) Radiotherapy for Non-metastatic Prostate Cancer
    Bekelman, J. E.
    Mitra, N.
    Efstathiou, J.
    Liao, K.
    Sunderland, R.
    Yeboa, D. N.
    Armstong, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S77 - S77