Continuous-flow/stopped-flow system using an immunobiosensor for quantification of human serum IgG antibodies to Helicobacter pylori

被引:17
作者
Messina, GA [1 ]
Torriero, AA [1 ]
De Vito, IE [1 ]
Olsina, RA [1 ]
Raba, J [1 ]
机构
[1] Natl Univ San Luis, Dept Chem, RA-5700 San Luis, Argentina
关键词
ELISA; Helicobacter pylori; amperometric immunoreactor; horseradish peroxidase; hydroquinone; FIA;
D O I
10.1016/j.ab.2004.07.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conventional methods, such as gastric biopsy, enzyme-linked immunosorbent assay (ELISA), culture, require a long time for the determination of Helicobacter pylori infections. This study reports an amperometric immunoreactor for rapid and sensitive quantification of human serum immunoglobulin G (IgG) antibodies to H. pylori. Antibodies in the serum sample are allowed to react immunologically with the purified H. pylori antigens that are immobilized on a rotating disk. The bound antibodies are quantified by horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to human IgG. HRP in the presence of hydrogen peroxide catalyzes the oxidation of hydroquinone to p-benzoquinone. The electrochemical reduction back to hydroquinone is detected on a glassy carbon electrode surface at -0.15 V. The electrochemical detection can be done within 1 min, and the analysis time does not exceed 30 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.6 and 1.9 U ml(-1), respectively. The amperometric immunoreactors showed higher sensitivity and lower time consumed than did the standard spectrophotometric detection ELISA method. It can also be used for rapid analysis in conventional and field conditions in biological, physiological, and analytical practices. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 29 条
  • [1] ATHEY D, 1991, J IMMUNOL METHODS, V176, P153
  • [2] New variants of enzyme immunoassay of antibodies to DNA
    Babkina, SS
    Medyantseva, EP
    Budnikov, HC
    Tyshiek, MP
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (21) : 3827 - 3831
  • [3] The bacteria behind ulcers
    Blaser, MJ
    [J]. SCIENTIFIC AMERICAN, 1996, 274 (02) : 104 - 107
  • [4] BOSCH A M G, 1978, P175
  • [5] ELECTROCATALYTIC OXIDATION OF NADH AND ASCORBIC-ACID ON ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES
    CENAS, N
    ROZGAITE, J
    POCIUS, A
    KULYS, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 154 (1-2): : 121 - 128
  • [6] ACCURACY OF INVASIVE AND NONINVASIVE TESTS TO DIAGNOSE HELICOBACTER-PYLORI INFECTION
    CUTLER, AF
    HAVSTAD, S
    MA, CK
    BLASER, MJ
    PEREZPEREZ, GI
    SCHUBERT, TT
    [J]. GASTROENTEROLOGY, 1995, 109 (01) : 136 - 141
  • [7] Regular review -: Treatment of Helicobacter pylori infection
    de Boer, WA
    Tytgat, GNJ
    [J]. BRITISH MEDICAL JOURNAL, 2000, 320 (7226) : 31 - 34
  • [8] PREVALENCE OF HELICOBACTER-PYLORI INFECTION AND HISTOLOGIC GASTRITIS IN ASYMPTOMATIC PERSONS
    DOOLEY, CP
    COHEN, H
    FITZGIBBONS, PL
    BAUER, M
    APPLEMAN, MD
    PEREZPEREZ, GI
    BLASER, MJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 321 (23) : 1562 - 1566
  • [9] CHARACTERIZATION OF THE HELICOBACTER-PYLORI UREASE AND PURIFICATION OF ITS SUBUNITS
    EVANS, DJ
    EVANS, DG
    KIRKPATRICK, SS
    GRAHAM, DY
    [J]. MICROBIAL PATHOGENESIS, 1991, 10 (01) : 15 - 26
  • [10] FOX JG, 1992, AM J GASTROENTEROL, V87, P1554