A directly converting high-resolution intra-oral X-ray imaging sensor

被引:6
|
作者
Spartiotis, K [1 ]
Pyyhtiä, J [1 ]
Schulman, T [1 ]
Puhakka, K [1 ]
Muukkonen, K [1 ]
机构
[1] iXimaging Plc, FIN-02200 Espoo, Finland
关键词
pixel detector; X-ray imaging; bump bonding;
D O I
10.1016/S0168-9002(03)00615-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A digital intra-oral X-ray imaging sensor with an active area of 3.6 x 2.9 cm(2) and consisting of six charge-integrating CMOS signal readout circuits bump bonded to one high-resistivity silicon pixel detector has been developed and tested. The pixel size is 35 mum. The X-rays entering the sensor window are converted directly to electrical charge in the depleted detector material yielding minimum lateral signal spread and maximum image sharpness. The signal charge is collected on the gates of the input field effect transistors of the CMOS signal readout circuits. The analog signal readout is performed by multiplexing in the current mode independent of the signal charge collection enabling multiple readout cycles with negligible dead time and thus imaging with wide dynamic range. Since no intermediate conversion material of X-rays to visible light is needed, the sensor structure is very compact. The analog image signals are guided from the sensor output through a thin cable to signal processing, AD conversion and memory circuitry, which is realized as an intermediate electronic unit between the sensor and the computer. This unit controls the sensor, collects the data and transfers it via one of the standard computer buses for image processing, display and storage. The overall sensor design and operation are described and experimental MTF, SNR and DQE data are presented together with X-ray images. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 50 条
  • [1] Improvement of the radiation hardness of a directly converting high resolution intra-oral X-ray imaging sensor
    Spartiotis, K
    Pyyhtiä, J
    Schulman, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03) : 579 - 584
  • [2] High-resolution x-ray imaging of extended lasing plasmas
    Forster, E
    Hutcheon, RJ
    Renner, O
    Uschmann, I
    Vollbrecht, M
    Nantel, M
    Klisnick, A
    Jaegle, P
    APPLIED OPTICS, 1997, 36 (04): : 831 - 840
  • [3] High-resolution X-ray diffraction imaging in a tabletop system
    Greenberg, Joel A.
    Dudley, Colt
    Moody, Ryan
    Richmond, Turner
    Espenhahn, Eric
    Pike, Daniel
    Kida, Sakurako
    Kapadia, Anuj J.
    Coccarelli, David
    ANOMALY DETECTION AND IMAGING WITH X-RAYS, ADIX IX, 2024, 13043
  • [4] Development of a digital X-ray imaging module for portable high-resolution imaging applications
    Cho, H
    Jeong, M
    Kim, S
    Lee, B
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 46 (05) : 1096 - 1101
  • [5] Light Management of Metal Halide Scintillators for High-Resolution X-Ray Imaging
    Xu, Xiuwen
    Xie, Yue-Min
    Shi, Huaiyao
    Wang, Yongquan
    Zhu, Xianjun
    Li, Bing-Xiang
    Liu, Shujuan
    Chen, Bing
    Zhao, Qiang
    ADVANCED MATERIALS, 2024, 36 (03)
  • [6] Optimization of CMOS active pixels with high signal-to-noise ratio for high-resolution X-ray imaging
    Kim, Young Soo
    Kim, Kwang Hyun
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) : 248 - 251
  • [7] High-resolution x-ray luminescence computed tomography
    Lun, Michael C.
    Li, Changqing
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [8] Metal Halide Perovskite Nanosheet for X-ray High-Resolution Scintillation Imaging Screens
    Zhang, Yuhai
    Sun, Ruijia
    Qi, Xiangyu
    Fu, Kaifang
    Chen, Qiushui
    Ding, Yuchong
    Xu, Liang-Jin
    Liu, Lingmei
    Han, Yu
    Malko, Anton V.
    Liu, Xiaogang
    Yang, Huanghao
    Bakr, Osman M.
    Liu, Hong
    Mohammed, Omar F.
    ACS NANO, 2019, 13 (02) : 2520 - 2525
  • [9] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Rudolph M. Snoeren
    Michael Söderman
    Johannes N. Kroon
    Ruben B. Roijers
    Peter H. N. de With
    Drazenko Babic
    Neuroradiology, 2012, 54 : 155 - 162
  • [10] High-resolution 3D X-ray imaging of intracranial nitinol stents
    Snoeren, Rudolph M.
    Soderman, Michael
    Kroon, Johannes N.
    Roijers, Ruben B.
    de With, Peter H. N.
    Babic, Drazenko
    NEURORADIOLOGY, 2012, 54 (02) : 155 - 162