Stability indicating reverse phase (RP)-high-performance liquid chromatography method development and validation for the simultaneous estimation of olanzapine and samidorphan in bulk and tablets

被引:3
作者
Kumar, Hathibelagal Mundarinti [1 ,2 ,4 ,5 ]
Chandrasekhar, Kothapalli [3 ]
机构
[1] Jawaharlal Nehru Technol Univ, Dept Pharmaceut Sci, Anantapur, India
[2] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool, India
[3] Krishna Univ, Dept Chem, Machilipatnam, Andhra Pradesh, India
[4] Jawaharlal Nehru Technol Univ Anantapur, Ananthapuramu & Dept Pharm, Sri G Pullareddy Govt Polytech, BThandrapadu, Kurnool 518007, Andhra Pradesh, India
[5] Sri G Pullareddy Govt Polytech, Dept Pharm, B Thandrapadu, Kurnool 518007, Andhra Pradesh, India
关键词
high-performance liquid chromatography method; olanzapine; samidorphan; stability indicating and validation; PROCESS-RELATED IMPURITIES; SCHIZOPHRENIA; FLUOXETINE; HPLC; SPECTROPHOTOMETRY; BIOEQUIVALENCE; FORMULATIONS;
D O I
10.4103/epj.epj_64_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background Patients with schizophrenia are given a combination tablet combining olanzapine (OLA), an atypical antipsychotic and samidorphan (SAM), an opioid receptor antagonist. Objectives In bulk and tablet dosage forms, a stability-indicating reverse phase (RP)-high-performance liquid chromatography technique for the simultaneous determination of OLA and SAM has been developed and validated. Materials and methods The chromatographic analysis was performed using an isocratic mobile phase of 0.1% formic acid in water : methanol : acetonitrile (10 : 40 : 50, v/v) at a flow rate of 0.8 ml/min, and the eluents were monitored at an isosbestic point of 285 nm. Results and conclusion The suggested method's specificity, precision, accuracy, linearity, and robustness were all validated according as per International Conference on Harmonization guidelines. The method's stability was validated by forced degradation experiments. Retention times for OLA and SAM were 2.85 and 4.79 min, respectively. The method was found to be precise and accurate. SAM linearity was found to be between 14.0 and 45.0 mu g/ml, whereas OLA linearity was found to be between 22.5 and 67.5 mu g/ml. The limit of detection (LOD) and limit of quantification (LOQ) of OLA were 2.65 and 8.85 mu g/ml, respectively, whereas the LOD and LOQ of SAM were 8.12 and 27.06 mu g/ml, respectively. As a result, the suggested high-performance liquid chromatography method for the quantification of OLA and SAM was reliable, repeatable, accurate, and sensitive.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 37 条
  • [1] Alsante K. M., 2001, Handbook of Modern Pharmaceutical Analysis, P85
  • [2] [Anonymous], 2003, Q1 A R2 STABILITY TE
  • [3] Voltammetric, spectrophotometric, and high performance liquid chromatographic analysis of olanzapine
    Biryol, I
    Erk, N
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2497 - 2513
  • [4] Buckley PF, 1999, J CLIN PSYCHIAT, V60, P52
  • [5] Cánovas M, 2011, ARZNEIMITTEL-FORSCH, V61, P75, DOI 10.1055/s-0031-1296170
  • [6] Current approaches to treatments for schizophrenia spectrum disorders, part II: psychosocial interventions and patient-focused perspectives in psychiatric care
    Chien, Wai Tong
    Leung, Sau Fong
    Yeung, Frederick K. K.
    Wong, Wai Kit
    [J]. NEUROPSYCHIATRIC DISEASE AND TREATMENT, 2013, 9 : 1463 - 1481
  • [7] Effects of Olanzapine Combined With Samidorphan on Weight Gain in Schizophrenia: A 24-Week Phase 3 Study
    Correll, Christoph U.
    Newcomer, John W.
    Silverman, Bernard
    DiPetrillo, Lauren
    Graham, Christine
    Jiang, Ying
    Du, Yangchun
    Simmons, Adam
    Hopkinson, Craig
    McDonnell, David
    Kahn, Rene S.
    [J]. AMERICAN JOURNAL OF PSYCHIATRY, 2020, 177 (12) : 1168 - 1178
  • [8] Samidorphan, an opioid receptor antagonist, attenuates drug-induced increases in extracellular dopamine concentrations and drug self-administration in male Wistar rats
    Cunningham, Jacobi I.
    Todtenkopf, Mark S.
    Dean, Reginald L.
    Azar, Marc R.
    Koob, George F.
    Deaver, Daniel R.
    Eyerman, David J.
    [J]. PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 2021, 204
  • [9] Improving outcomes of first-episode psychosis: an overview
    Fusar-Poli, Paolo
    McGorry, Patrick D.
    Kane, John M.
    [J]. WORLD PSYCHIATRY, 2017, 16 (03) : 251 - 265
  • [10] ICH, 2005, INT C HARM FOOD DRUG