Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom

被引:32
作者
Behrendt, Florian F. [1 ]
Bruners, Philipp [1 ]
Keil, Sebastian [1 ]
Plumhans, Cedric [1 ]
Mahnken, Andreas H. [1 ]
Das, Marco [1 ]
Ackermann, Diana [2 ]
Guenther, Rolf W. [1 ]
Muehlenbruch, Georg [1 ]
机构
[1] Univ Hosp RWTH Aachen, Dept Diagnost & Intervent Radiol, D-52057 Aachen, Germany
[2] Univ Hosp RWTH Aachen, Inst Med Stat, D-52057 Aachen, Germany
关键词
Saline chaser; Contrast media; Phantom; CT; COMPUTED-TOMOGRAPHY; PULMONARY-ARTERY; PEAK ENHANCEMENT; POWER INJECTOR; ABDOMINAL CT; FLUSH; ANGIOGRAPHY; MODEL; REDUCTION; AORTA;
D O I
10.1016/j.ejrad.2009.01.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the influence of different saline chaser volumes and different saline chaser flow rates on the intravascular contrast enhancement in MDCT. Materials and methods: In a physiological flow phantom contrast medium (120 ml, 300 mgl/ml, Ultravist 300) was administered at a flow rate of 6 ml/s followed by different saline chaser volumes (0, 30, 60 and 90 ml) at the same injection rate or followed by a 30-ml saline chaser at different injection rates (2, 4, 6 and 8 ml/s). Serial CT-scans at a level covering the pulmonary artery, the ascending and the descending aorta replica were obtained. Time-enhancement curves were computed and both pulmonary and aortic peak enhancement and peak time were determined. Results: Compared to contrast medium injection without a saline chaser the pushing with a saline chaser (30, 60, and 90 ml) resulted in a statistically significant increased pulmonary peak enhancement (all p = 0.008) and prolonged peak time (p = 0.032, p = 0.024 and p = 0.008, respectively). Highest aortic peak enhancement values were detected for a saline chaser volume of 30 ml. A saline chaser flow rate of 8 ml/s resulted in the highest pulmonary peak enhancement values compared to flow rates of 2, 4 and Omits (all p = 0.008). Aortic peak enhancement showed the highest values for a flow rate of 6 ml/s. Conclusion: A saline chaser volume of 30 ml and an injection rate of 6 ml/s are sufficient to best improve vascular contrast enhancement in the pulmonary artery and the aorta in MDCT. (C) 2009 Published by Elsevier Ireland Ltd.
引用
收藏
页码:688 / 693
页数:6
相关论文
共 17 条
  • [1] Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: Feasibility study
    Awai, K
    Hatcho, A
    Nakayama, Y
    Kusunoki, S
    Liu, D
    Hatemura, M
    Funama, Y
    Denbo, M
    Sato, N
    Yamashita, Y
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 379 - 385
  • [2] Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model
    Bae, KT
    Heiken, JP
    Brink, JA
    [J]. RADIOLOGY, 1998, 207 (03) : 647 - 655
  • [3] Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model
    Bae, KT
    Heiken, JP
    Brink, JA
    [J]. RADIOLOGY, 1998, 206 (02) : 455 - 464
  • [4] Introduction of a dedicated circulation phantom for comprehensive in vitro analysis of intravascular contrast material application
    Behrendt, Florian F.
    Bruners, Philipp
    Kalafut, John
    Mahnken, Andreas H.
    Keil, Sebastian
    Plumhans, Cedric
    Das, Marco
    Stanzel, Sven
    Wildberger, Joachim E.
    Pfeffer, Jochen
    Guenther, Rolf W.
    Muehlenbruch, Georg
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 729 - 736
  • [5] Using a saline chaser to decrease contrast media in abdominal CT
    Dorio, PJ
    Lee, FT
    Henseler, KP
    Pilot, M
    Pozniak, MA
    Winter, TC
    Shock, SA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) : 929 - 934
  • [6] Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform
    Fleischmann, D
    Hittmair, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) : 474 - 484
  • [7] Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    Haage, P
    Schmitz-Rode, T
    Hübner, D
    Piroth, W
    Günther, RW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) : 1049 - 1053
  • [8] Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    Hopper, KD
    Mosher, TJ
    Kasales, CJ
    TenHave, TR
    Tully, DA
    Weaver, JS
    [J]. RADIOLOGY, 1997, 205 (01) : 269 - 271
  • [9] Contrast-enhanced CT with saline flush technique using two automated injectors: How much contrast medium does it save?
    Irie, T
    Kajitani, M
    Yamaguchi, M
    Itai, Y
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (02) : 287 - 291
  • [10] Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography
    Kim, Dae Jung
    Kim, Tae Hoon
    Kim, Sang Jin
    Kim, Dong Phil
    Oh, Chi Suk
    Ryu, Young Hoon
    Kim, Young Jin
    Choi, Byoung Wook
    [J]. RADIOLOGY, 2008, 246 (01) : 110 - 115