Portable Accelerometer-Based Navigation System for Cup Placement of Total Hip Arthroplasty: A Prospective, Randomized, Controlled Study

被引:39
作者
Tanino, Hiromasa [1 ]
Nishida, Yasuhiro [1 ]
Mitsutake, Ryo [1 ]
Ito, Hiroshi [1 ]
机构
[1] Asahikawa Med Univ, Dept Orthopaed Surg, Midorigaoka Higashi 2-1-1-1, Asahikawa, Hokkaido 0788510, Japan
关键词
navigation; randomized trial; portable; total hip arthroplasty; cup position; TOTAL KNEE ARTHROPLASTY; COMPUTER-ASSISTED NAVIGATION; ACETABULAR COMPONENT; SAFE ZONE; ACCURACY; ALIGNMENT;
D O I
10.1016/j.arth.2019.08.044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Malposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique. Methods: In a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans. Results: An average cup abduction of 39.2 degrees +/- 4.6 degrees (range, 27 degrees to 50 degrees) and an average cup anteversion of 14.6 degrees +/- 6.1 degrees (range, 1 degrees to 27.5 degrees) were found in the navigation group, and an average cup abduction of 42.9 degrees +/- 8.0 degrees (range, 23 degrees to 73 degrees) and an average cup anteversion of 11.6v +/- 7.7 degrees (range, -12.1 degrees to 25 degrees) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P =.001). The deviations from the target cup position were significantly lower in the navigation group (P =.001,.016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P =.006). The navigation procedure took a mean of 10 minutes longer than the conventional technique. Conclusion: Use of the portable, accelerometer-based hip navigation system can improve cup positioning in THA. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 50 条
  • [21] Accelerometer-based portable navigation, a faster guide compared to computer-assisted navigation in bilateral total knee arthroplasty-a randomized controlled study
    Swamy, Arun M.
    Malhotra, Rajesh
    Digge, Vijaykumar
    Manhas, Vikrant
    Gautam, Deepak
    Srivastava, Deep Narayana
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 786 - 792
  • [22] CORR Insights®: Does Augmented Reality-based Portable Navigation Improve the Accuracy of Cup Placement in THA Compared With Accelerometer-based Portable Navigation? A Randomized Controlled Trial
    Keeney, James A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (08) : 1524 - 1526
  • [23] Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 23
  • [24] Validation of navigation assisted cup placement in total hip arthroplasty
    M. Ajith Kumar
    M. Shantharam Shetty
    Kanthi G. Kiran
    Abhishek R. Kini
    International Orthopaedics, 2012, 36 : 17 - 22
  • [25] Two- and three-dimensional measurements of leg length change using an accelerometer-based portable navigation system in total hip arthroplasty
    Masahiro Hasegawa
    Yohei Naito
    Shine Tone
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 24
  • [26] Two- and three-dimensional measurements of leg length change using an accelerometer-based portable navigation system in total hip arthroplasty
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [27] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [28] Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty
    Huang, Eddie H.
    Copp, Steven N.
    Bugbee, William D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11) : 1906 - 1910
  • [29] A Prospective, Randomized Study of Surgical Positioning Software Shows Improved Cup Placement in Total Hip Arthroplasty
    Hamilton, William G.
    Parks, Nancy L.
    McDonald, James F., III
    Pfefferle, Kiel J.
    ORTHOPEDICS, 2019, 42 (01) : 42 - 47
  • [30] Accelerometer-Based Portable Navigation System Is Useful for Tibial Bone Cutting in Modified Kinematically Aligned Total Knee Arthroplasty
    Tsubosaka, Masanori
    Kamenaga, Tomoyuki
    Kuroda, Yuichi
    Takayama, Koji
    Hashimoto, Shingo
    Ishida, Kazunati
    Hayashi, Shinya
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF KNEE SURGERY, 2021, 34 (08) : 870 - 876