Systematic analysis of bias and variability of texture measurements in computed tomography

被引:12
|
作者
Robins, Marthony [1 ,2 ]
Solomon, Justin [1 ,2 ]
Hoye, Jocelyn [1 ,2 ,3 ,4 ]
Abadi, Ehsan [1 ,2 ,4 ]
Marin, Daniele [2 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[3] Duke Univ, Med Phys Grad Program, Durham, NC USA
[4] Duke Univ, Dept Elect & Comp Engn, Durham, NC USA
[5] Duke Univ, Dept Phys, Durham, NC 27706 USA
[6] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
基金
美国国家卫生研究院;
关键词
radiomics; computed tomography; texture analysis; simulation; tumor; quantitative; VOLUME ESTIMATION; LUNG NODULES; CT; FEATURES; HETEROGENEITY; RADIOMICS; IMAGES; SIZE;
D O I
10.1117/1.JMI.6.3.033503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Texture is a key radiomics measurement for quantification of disease and disease progression. The sensitivity of the measurements to image acquisition, however, is uncertain. We assessed bias and variability of computed tomography (CT) texture feature measurements across many clinical image acquisition settings and reconstruction algorithms. Diverse, anatomically informed textures (texture A, B, and C) were simulated across 1188 clinically relevant CT imaging conditions representing four in-plane pixel sizes (0.4, 0.5, 0.7, and 0.9 mm), three slice thicknesses (0.625, 1.25, and 2.5 mm), three dose levels (CTDIvol 1.90, 3.75, and 7.50 mGy), and 33 reconstruction kernels. Imaging conditions corresponded to noise and resolution properties representative of five commercial scanners (GE LightSpeed VCT, GE Discovery 750 HD, GE Revolution, Siemens Definition Flash, and Siemens Force) in filtered backprojection and iterative reconstruction. About 21 texture features were calculated and compared between the ground-truth phantom (i.e., preimaging) and its corresponding images. Each feature was measured with four unique volumes of interest (VOls) sizes (244, 579, 1000, and 1953 mm(3). To characterize the bias, the percentage relative difference [PRD(%)] in each feature was calculated between the imaged scenario and the ground truth for all VOI sizes. Feature variability was assessed in terms of (1) sigma(PRD)(%) indicating the variability between the ground truth and simulated image scenario based on the PRD(%), (2) COVf indicating the simulation-based variability, and (3) COVT indicating the natural variability present in the ground-truth phantom. The PRD ranged widely from -97% to 1220%, with an underlying variability (sigma) of up to 241%. Features such as gray-level nonuniformity, texture entropy, sum average, and homogeneity exhibited low susceptibility to reconstruction kernel effects (PRD < 3%) with relatively small sigma(PRD) (%) (<= 5%) across imaging conditions. The dynamic range of results indicates that image acquisition and reconstruction conditions of in-plane pixel sizes, slice thicknesses, dose levels, and reconstruction kernels can lead to significant bias and variability in feature measurements. (C) 2019 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Variability in computed tomography diameter measurements of solid renal masses
    Orton, Lorenzo P.
    Cohan, Richard H.
    Davenport, Matthew S.
    Parker, Robert A.
    Parameswaran, Aishwarya
    Caoili, Elaine M.
    Kaza, Ravi K.
    Francis, Isaac R.
    Ellis, James H.
    Wolf, J. Stuart
    Hafez, Khaled
    ABDOMINAL IMAGING, 2014, 39 (03): : 533 - 542
  • [22] Systematic analysis of measurement variability in lung cancer with multidetector computed tomography
    Jiang, Binghu
    Zhou, Dan
    Sun, Yujie
    Wang, Jichen
    ANNALS OF THORACIC MEDICINE, 2017, 12 (02) : 95 - 100
  • [23] Computed Tomography Embolus Texture Analysis as a Prognostic Marker of Acute Pulmonary Embolism
    Leonhardi, Jakob
    Bailis, Nikolaos
    Lerche, Marianne
    Denecke, Timm
    Surov, Alexey
    Meyer, Hans-Jonas
    ANGIOLOGY, 2023, 74 (05) : 461 - 471
  • [24] Computed tomography texture analysis to facilitate therapeutic decision making in hepatocellular carcinoma
    Li, Meng
    Fu, Sirui
    Zhu, Yanjie
    Liu, Zaiyi
    Chen, Shuting
    Lu, Ligong
    Liang, Changhong
    ONCOTARGET, 2016, 7 (11) : 13248 - 13259
  • [25] Texture analysis of computed tomography data using morphologic and metabolic delineation of esophageal cancer-relation to tumor type and neoadjuvant therapy response
    Zhang, Y. -H.
    Herlin, G.
    Rouvelas, I.
    Nilsson, M.
    Lundell, L.
    Brismar, T. B.
    DISEASES OF THE ESOPHAGUS, 2019, 32 (04)
  • [26] In vivo study of cone beam computed tomography texture analysis of mandibular condyle and its correlation with gender and age
    Nussi, Amanda Drumstas
    de Castro Lopes, Sergio Lucio Pereira
    De Rosa, Catharina Simioni
    Gomes, Joao Pedro Perez
    Ogawa, Celso Massahiro
    Braz-Silva, Paulo Henrique
    Costa, Andre Luiz Ferreira
    ORAL RADIOLOGY, 2023, 39 (01) : 191 - 197
  • [27] Computed tomography texture-based models for predicting KIT exon 11 mutation of gastrointestinal stromal tumors
    Guo, Chuangen
    Zhou, Hao
    Chen, Xiao
    Feng, Zhan
    HELIYON, 2023, 9 (10)
  • [28] Measurements of heterogeneity in gliomas on computed tomography relationship to tumour grade
    Skogen, Karoline
    Ganeshan, Balaji
    Good, Catriona
    Critchley, Giles
    Miles, Ken
    JOURNAL OF NEURO-ONCOLOGY, 2013, 111 (02) : 213 - 219
  • [29] Incidental Thyroid Nodule on Chest Computed Tomography: Application of Computed Tomography Texture Analysis in Prediction of Ultrasound Classification
    Jo, Jung In
    Kim, Jung Im
    Ryu, Jung Kyu
    Lee, Han Na
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (03) : 480 - 486
  • [30] Texture Analysis and Machine Learning for Detecting Myocardial Infarction in Noncontrast Low-Dose Computed Tomography Unveiling the Invisible
    Mannil, Manoj
    von Spiczak, Jochen
    Manka, Robert
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2018, 53 (06) : 338 - 343