Small field dose measurements using plastic scintillation detector in heterogeneous media

被引:14
作者
Xue, Jinyu [1 ]
McKay, Jesse D. [2 ]
Grimm, Jimm [3 ]
Cheng, Chee-Wai [4 ]
Berg, Ronald [2 ]
Grimm, Shu-Ya Lisa [5 ]
Xu, Qianyi [6 ]
Subedi, Gopal [7 ]
Das, Indra J. [1 ]
机构
[1] NYU, Dept Radiat Oncol, Langone Med Ctr, 550 1st Ave, New York, NY 10016 USA
[2] Erlanger Hlth Syst, Dept Radiat Oncol, Chattanooga, TN 37403 USA
[3] Johns Hopkins Univ Hosp, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[4] Univ Hosp Cleveland Med Ctr, Dept Radiat Oncol, Cleveland, OH 44106 USA
[5] Fox Chase Canc Ctr, Acad Urol, King Of Prussia, PA 19406 USA
[6] MD Anderson Canc Ctr Cooper, Dept Radiat Oncol, Camden, NJ 08103 USA
[7] Eastern Maine Med Ctr, Dept Radiat Oncol, Bangor, ME 04401 USA
关键词
heterogeneity corrections; Monte Carlo; plastic scintillation detectors; small field; stereotactic; ENERGY BEAM DOSIMETRY; MV PHOTON BEAMS; MONTE-CARLO; RADIATION-THERAPY; DIAMOND DETECTOR; RADIOTHERAPY; AAPM;
D O I
10.1002/mp.12272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate a plastic scintillation detector for the measurement of small field dosimetry and to verify the accuracy of measured dose in comparison with Monte Carlo calculation in a heterogeneous medium. Methods: The study is performed with CyberKnife planning and delivery system. The setup consists of a custom made solid lung phantom with the insert of an Exradin W1 scintillation detector or an Exradin A16 ion chamber. The measurement was done for a series of cone sizes from 5 mm to 60 mm, and the dose was calculated by Monte Carlo algorithm in MultiPlan workstation. The difference between measurement and calculation was reported. Results: Our preliminary results demonstrated the applicability of plastic scintillation detectors in the measurement of small field dosimetry in a heterogeneous medium. The difference between the calculated and measured output factors was less than 3% for all cone sizes from 60 mm down to 5 mm. Without any corrections, the measured dose from the scintillation detector calibrated to the ion chamber reading was also within 3% of the Monte Carlo calculation in the lung phantom for cone sizes 20 mm or larger. Conclusions: Small field dosimetry is particularly relevant to stereotactic radiation treatment. The accuracy of dose calculation for small static beams is critical to dose planning so would potentially affect the treatment outcomes in a heterogeneous medium. Our results have shown good agreement with plastic scintillation detector in both homogeneous and heterogeneous medium. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:3815 / 3820
页数:6
相关论文
共 26 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   A new formalism for reference dosimetry of small and nonstandard fields [J].
Alfonso, R. ;
Andreo, P. ;
Capote, R. ;
Huq, M. Saiful ;
Kilby, W. ;
Kjaell, P. ;
Mackie, T. R. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. ;
Vatnitsky, S. .
MEDICAL PHYSICS, 2008, 35 (11) :5179-5186
[3]  
[Anonymous], 2017, 483 INT ATOMIC ENERY
[4]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[5]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[6]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[7]   Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study [J].
Benmakhlouf, Hamza ;
Sempau, Josep ;
Andreo, Pedro .
MEDICAL PHYSICS, 2014, 41 (04)
[8]   On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters [J].
Chibani, Omar ;
Moftah, Belal ;
Ma, C. -M. Charlie .
MEDICAL PHYSICS, 2011, 38 (01) :188-201
[9]   Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams [J].
Ciancaglioni, I. ;
Marinelli, Marco ;
Milani, E. ;
Prestopino, G. ;
Verona, C. ;
Verona-Rinati, G. ;
Consorti, R. ;
Petrucci, A. ;
De Notaristefani, F. .
MEDICAL PHYSICS, 2012, 39 (07) :4493-4501
[10]   Validity of Inhomogeneity Correction in Small Felds Used in CyberKnife [J].
Das, I. ;
Cryan, G. .
MEDICAL PHYSICS, 2008, 35 (06)