Iodine Beam Hardening Correction for Single KVp CT and Quantification Accuracy Relative to Dual-Energy Monochromatic CT

被引:0
|
作者
Yadava, G. [1 ]
Imai, Y. [1 ]
Hsieh, J. [1 ]
机构
[1] GE Healthcare, Waukesha, WI USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-A-12A-1
引用
收藏
页码:452 / 452
页数:1
相关论文
共 50 条
  • [1] Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study
    Jacobsen, Megan C.
    Schellingerhout, Dawid
    Wood, Cayla A.
    Tamm, Eric P.
    Godoy, Myrna C.
    Sun, Jia
    Cody, Dianna D.
    RADIOLOGY, 2018, 287 (01) : 224 - 234
  • [2] A novel fast kilovoltage switching dual-energy CT with deep learning: Accuracy of CT number on virtual monochromatic imaging and iodine quantification
    Kojima, Tsukasa
    Shirasaka, Takashi
    Kondo, Masatoshi
    Kato, Toyoyuki
    Nishie, Akihiro
    Ishigami, Kousei
    Yabuuchi, Hidetake
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 253 - 261
  • [3] New Fast kVp Switching Dual-Energy CT: Reduced Severity of Beam Hardening Artifacts and Improved Image Quality in Reduced-Iodine Virtual Monochromatic Imaging
    Sugawara, Haruto
    Takayanagi, Tomoko
    Ishikawa, Takuya
    Katada, Yoshiaki
    Fukui, Rika
    Yamamoto, Yuzo
    Suzuki, Shigeru
    ACADEMIC RADIOLOGY, 2020, 27 (11) : 1586 - 1593
  • [4] Dual-Energy CT: Lower Limits of Iodine Detection and Quantification
    Jacobsen, Megan C.
    Cressman, Erik N. K.
    Tamm, Eric P.
    Baluya, Dodge L.
    Duan, Xinhui
    Cody, Dianna D.
    Schellingerhout, Dawid
    Layman, Rick R.
    RADIOLOGY, 2019, 292 (02) : 414 - 419
  • [5] Dual-Energy CT Iodine Accuracy Across Vendors and Platforms
    Jacobsen, M.
    Wood, C.
    Cody, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3835 - 3836
  • [6] Evaluation of Intra-Manufacturer Dual-Energy CT Iodine Quantification Accuracy: Phantom Studies
    Zhao, A.
    Borhani, A.
    Catania, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [7] Dual-Energy and Low-kVp CT in the Abdomen
    Yeh, Benjamin M.
    Shepherd, John A.
    Wang, Zhen J.
    Teh, Hui Seong
    Hartman, Robert P.
    Prevrhal, Sven
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) : 47 - 54
  • [8] Dual-Energy CT with Fast-KVp Switch
    Hsieh, J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2749 - +
  • [9] Dual-energy CT iodine quantification for characterizing focal thyroid lesions
    Lee, Do Hyung
    Lee, Young Hen
    Seo, Hyung Suk
    Lee, Ki Yeol
    Suh, Sang-il
    Ryoo, Inseon
    You, Sung-Hye
    Kim, Byungjun
    Yang, Kyung-Sook
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (04): : 1024 - 1031
  • [10] Quantification of iodine concentration by dual-energy CT in patients with acute pancreatitis
    Utrera Perez, E.
    Tardaguila de la Fuente, G.
    Martinez Rodriguez, C.
    Villanueva Campos, A.
    Jurado Basildo, C.
    Garcia Pouton, N.
    RADIOLOGIA, 2020, 62 (05): : 360 - 364