A Sensitive Industrial Process Model for Financial Losses Assessment Due to Voltage Sag and Short Interruptions

被引:18
|
作者
He, Han-Yang [1 ]
Zhang, Wen-Hai [1 ]
Wang, Ying [1 ]
Xiao, Xian-Yong [1 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
Voltage sags; short interruption; logical algebra; power quality; robust regression; CONTACTORS;
D O I
10.1109/TPWRD.2020.3006017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The financial loss assessment of industrial users due to voltage sag and short interruptions is important for distribution network performance evaluation and power quality enhancement scheme design. Existing assessment models are highly dependent on complete industrial process information, which is difficult to obtain. To solve this problem, a new sensitive industrial process model needs limited industrial processes information is proposed. In the proposed model, the sensitive equipment is modeled by voltage tolerance curves (VTC), and the truth table is used to characterize the logical relationship. As the industrial process information is limited, the boundary value of VTC and partial logical function values of the truth table are uncertain. To determine the model's uncertain parameters objectively, an optimization model with the goal of minimizing the deviation of the assessment loss is constructed, and the details of the algorithm are also given out. An example based on some investigation data is given to verify the effectiveness of the model and show how to use it.
引用
收藏
页码:1293 / 1301
页数:9
相关论文
共 50 条
  • [21] Sensitivity uncertainty assessment of sensitive equipment due to voltage sag based on maximum entropy principle
    School of Electrical Eng. and Information, Sichuan Univ, Chengdu 610065, China
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban), 2009, 5 (243-248):
  • [22] Behavior of induction motor due to voltage sags and short interruptions
    Gomez, JC
    Morcos, MM
    Reineri, CA
    Campetelli, GN
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) : 434 - 440
  • [23] ASSESSMENT OF VOLTAGE QUALITY PROBLEMS OF ELEVATOR EQUIPMENT DUE TO VOLTAGE SAG
    Kim, Gihyun
    Bai, Seokmyung
    Kim, Jaechul
    Lee, Heetae
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2010, 6 (11): : 5191 - 5201
  • [24] Non-additive measure and assessment method of the failure possibility of sensitive equipment due to voltage sag
    Li, Wan
    Gui, Xian-Ming
    Xiao, Xian-Yong
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (19): : 96 - 101
  • [25] Understanding and resolving voltage sag related problems for sensitive industrial customers
    Lim, PK
    Dorr, DS
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2886 - 2890
  • [26] Stochastic Estimation Trip Frequency of Sensitive Equipment Due to Voltage Sag
    Xiao, Xianyong
    Liu, Xuna
    Yang, Honggeng
    2008 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2008), VOLS 1-4, 2008, : 364 - 367
  • [27] Minimization of voltage sag induced financial losses in distribution systems using FACTS devices
    Goswami, A. K.
    Gupta, C. P.
    Singh, G. K.
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (03) : 767 - 774
  • [28] A probabilistic approach for assessment of financial loss due to equipment outage caused by voltage sag using cost matrix
    Behera, Chinmaya
    Banik, Abhishek
    Nandi, Jaydeep
    Reddy, Galiveeti Hemakumar
    Chakrapani, Pranju
    Goswami, Arup Kumar
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (03)
  • [29] Severity indices for assessment of equipment sensitivity to voltage sags and short interruptions
    Chan, J. Y.
    Milanovic, J. V.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 737 - +
  • [30] Voltage sag effects on sensitive equipment due to starting cycles of induction motor
    Gomez, J.C.
    Morcos, M.M.
    IEEE Power Engineering Review, 2002, 22 (08): : 51 - 52