共 50 条
Evaluation of 10 Cone-beam Computed Tomographic Devices for Endodontic Assessment of Fine Anatomic Structures
被引:8
作者:
Pinto, Jader Camilo
[1
,2
,3
]
Wanderley, Victor Aquino
[2
,3
,4
]
Vasconcelos, Karla de Faria
[2
,3
]
Leite, Andre Ferreira
[2
,3
,5
]
Pauwels, Ruben
[6
,7
]
Nadjmi, Mansour
[2
,3
]
Oliveira, Matheus L.
[4
]
Tanomaru-Filho, Mario
[1
]
Jacobs, Reinhilde
[2
,3
,8
]
机构:
[1] Sao Paulo State Univ, Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
[2] Katholieke Univ Leuven, OMFS IMPATH Res Grp, Dept Imaging & Pathol, Fac Med, Leuven, Belgium
[3] Univ Hosp Leuven, Oral & Maxillofacial Surg, Leuven, Belgium
[4] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, Piracicaba, SP, Brazil
[5] Univ Brasilia, Dept Dent, Fac Hlth Sci, Brasilia, DF, Brazil
[6] Aarhus Univ, Aarhus Inst Adv Studies, Aarhus, Denmark
[7] Katholieke Univ Leuven, Dept Mech Engn, Leuven, Belgium
[8] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
基金:
欧盟地平线“2020”;
巴西圣保罗研究基金会;
关键词:
Anatomy;
artifacts;
cone-beam computed tomography;
endodontics;
VERTICAL ROOT FRACTURES;
FILLED TEETH;
MB2;
CANALS;
VOXEL SIZE;
CT;
CBCT;
ABSENCE;
ACCURACY;
ABILITY;
D O I:
10.1016/j.joen.2021.02.013
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Introduction: The purpose of this study was to classify 10 cone-beam computed tomographic (CBCT) devices using a ranking model according to the detection of fine endodontic structures. Methods: A dedicated dentate anthropomorphic phantom was scanned 2 times using 10 CBCT devices without any metal (metal-free condition) and with an endodontically treated tooth containing a metallic post (metal condition). A reference image acquired on an industrial micro-CT scanner was used to register all CBCT images, yielding corresponding anatomic slices. Afterward, 3 experienced observers assessed all acquired CBCT images for their ability to assess a narrow canal, isthmus, and apical delta ramification using a categoric rank from 1 (best) to 10 (worst). Fleiss kappa statistics were used to calculate intra-and interobserver agreements for each CBCT device separately. Based on the observers' scores, general linear mixed models were applied to compare image quality among different CBCT devices for performing endodontic diagnostic tasks (a 5 .05). Results: The 10 CBCT devices performed differently for the evaluated endodontic tasks (P , .05), with 3 devices performing better for endodontic feature detection. Yet, in the presence of metal, only 2 devices were able to keep a high level of endodontic feature detection. Conclusions: The evaluated endodontic tasks were CBCT device dependent, and their detection was influenced by the presence of metal. (J Endod 2021;47:947-953.)
引用
收藏
页码:947 / 953
页数:7
相关论文