Effects of hypoxia on coronary flow reserve as determined by myocardial contrast echocardiography in swine

被引:0
作者
Yang, Y
Li, SQ
Peters, B
DeMaria, AN
机构
[1] First Affiliated Hosp, Kunming Med Coll, Dept Cardiol, Kunming 650032, Peoples R China
[2] Univ Calif San Diego, Dept Cardiol, San Diego, CA 92103 USA
关键词
anoxia; coronary flow reserve; myocardial contrast echocardiography;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Time-intensity curves derived from microbubble destruction/ refilling sequences and recorded using myocardial contrast echocardiography ( MCE) can provide parameters that correlate with coronary blood flow. The response of these parameters to adenosine vasodilatation correlates with coronary flow reserve ( CFR) measured by fluorescent microsphere techniques ( FMT). Currently, no data exist regarding the effect of physiological variables, such as hypoxia, on the determination of CFR by MCE. The purpose of this study was to define the effects of decreases in blood partial pressure of oxygen (PO2) on CFR as measured by MCE. Methods Studies were performed in 9 closed chest swine. Low-energy, real-time MCE was performed with commercial instruments in short axis view at papillary muscle level while infusing BR, at 30 ml/h. High-energy ultrasound bursts ( referred to as FLASH frames) destroyed the bubbles every 15 cardiac cycles, and resultant time-intensity curves derived from these sequences were fitted to the exponential function y = A ( 1-e(-bt)) + c, from which the rate of signal rise ( b) was obtained. CFR was calculated as the ratio of b values after adenosine infusion to baseline and was obtained during the control period and after decreasing blood PO2 by giving nitrogen via a respirator to create artificial hypoxic conditions. CFR was independently determined by FMT. Results Nitrogen led to significant decreases in mean PO2 from (120.6 +/- 18.9) mmHg to (51.8 +/- 15.9) mmHg (P < 0.01). Adenosine produced a similar increase in CFR (2.5 fold vs 3.1 fold) as assessed by MCE and FMT during the control period. The decrease in PO2 post nitrogen resulted in a slight increase in values at rest: 0.46 +/- 0.15 to 0.53 +/- 0.18 for b and ( 1.39 +/- 0.66) ml . min-(1) (.) g(-1) to (1.72 +/- 0.30) ml . min(-1) . g(-1) for myocardial blood flow (MBF) (both P < 0.05). In addition, values decreased in response to adenosine using both techniques: 1.05 +/- 0.35 to 0.82 +/- 0.27 for b and (4.30 +/- 3.16) ml . min(-1). g(-1) to (3.93 +/- 1.27) ml . min(-1) . g(-1) for MBF (both P < 0.05). Thus, CFR was markedly reduced under hypoxic conditions, to 1.4 by MCE (P < 0.05 compared with the baseline), and to 2.5 by FMT (P > 0.05 compared with the baseline). Conclusions CFR values diminish under hypoxic conditions according to both MCE and FMT. The reductions in CFR involve both an increase in resting values and a decrease in post adenosine measurements, as determined by both techniques. The reduction in CFR under hypoxia is slightly greater using MCE than using FMT. Physiological variables, such as hypoxia, must be taken into consideration when assessing CFR by MCE.
引用
收藏
页码:1453 / 1458
页数:6
相关论文
共 18 条
  • [1] EFFECTS OF ACUTE PROLONGED HYPOXIA ON CARDIOVASCULAR DYNAMICS IN DOGS
    BORGIA, JF
    HORVATH, SM
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (05) : 784 - 789
  • [2] Dong SH, 2002, CHINESE MED J-PEKING, V115, P837
  • [3] VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION
    GLENNY, RW
    BERNARD, S
    BRINKLEY, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) : 2585 - 2597
  • [4] Myocardial contrast echocardiography is superior to other known modalities for assessing myocardial reperfusion after acute myocardial infarction
    Greaves, K
    Dixon, SR
    Fejka, M
    O'Neill, WW
    Redwood, SR
    Marber, MS
    Senior, R
    [J]. HEART, 2003, 89 (02) : 139 - 144
  • [5] JONES DP, 1981, J THORAC CARDIOV SUR, V82, P216
  • [6] INFLUENCE OF ARTERIAL HYPOXIA ON CARDIAC AND CORONARY DYNAMICS IN CONSCIOUS SINOAORTIC-DENERVATED DOG
    KRASNEY, JA
    KOEHLER, RC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (06) : 1012 - 1018
  • [7] Lafitte S, 2001, J AM SOC ECHOCARDIOG, V14, P1010
  • [8] Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography
    Leong-Poi, H
    Le, E
    Rim, SJ
    Sakuma, T
    Kaul, S
    Wei, K
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (12) : 1173 - 1182
  • [9] Li AL, 2002, CHINESE MED J-PEKING, V115, P1889
  • [10] Lupi A, 1997, EUR HEART J, V18, P614