Carbon dioxide and argon gas embolism during laparoscopic hepatic resection

被引:49
作者
Min, S. K. [1 ]
Kim, J. H. [1 ]
Lee, S. Y. [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Anesthesiol & Pain Med, Suwon 441749, South Korea
关键词
venous gas embolism; Argon beam coagulation; system; laparoscopy;
D O I
10.1111/j.1399-6576.2007.01361.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
During laparoscopic hepatic resection, an abrupt decrease in FE ' CO2 (from 28 mmHg to 9 mmHg) associated with near cardiac arrest occurred concomitantly with hepatic vein laceration and the use of an argon beam coagulator system. During venous gas embolism, transesophageal echocardiography (TEE) proved the transpulmonary passage of the gas. In the post-operative period, the patient developed pulmonary edema and made a full recovery after 5 days. This is a case report of a possible paradoxic carbon dioxide (CO2) and argon gas embolism by transpulmonary passage during laparoscopic hepatic resection.
引用
收藏
页码:949 / 953
页数:5
相关论文
共 19 条
[1]   PATHOPHYSIOLOGY OF INTRAVENOUS AIR-EMBOLISM IN DOGS [J].
ADORNATO, DC ;
GILDENBERG, PL ;
FERRARIO, CM ;
SMART, J ;
FROST, EAM .
ANESTHESIOLOGY, 1978, 49 (02) :120-127
[2]   FATAL CARBON-DIOXIDE EMBOLISM AND SEVERE HEMORRHAGE DURING LAPAROSCOPIC SALPINGECTOMY [J].
BECK, DH ;
MCQUILLAN, PJ .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (02) :243-245
[3]   PARADOXIC AIR-EMBOLISM DURING VENOUS AIR-EMBOLISM - TRANSESOPHAGEAL ECHOCARDIOGRAPHIC EVIDENCE OF TRANSPULMONARY AIR PASSAGE [J].
BEDELL, EA ;
BERGE, KH ;
LOSASSO, TJ .
ANESTHESIOLOGY, 1994, 80 (04) :947-950
[4]   TRANS-PULMONARY PASSAGE OF VENOUS AIR EMBOLI [J].
BUTLER, BD ;
HILLS, BA .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (02) :543-547
[5]   LUNG AS A FILTER FOR MICROBUBBLES [J].
BUTLER, BD ;
HILLS, BA .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (03) :537-543
[6]  
DESAI S, 1982, ANESTH ANALG, V61, P699
[7]   The effects of experimental venous carbon dioxide embolization on hemodynamic and respiratory variables [J].
Jersenius, U ;
Fors, D ;
Rubertsson, S ;
Arvidsson, D .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (02) :156-162
[8]   EFFECTS OF DIFFERENT-SIZE MICROEMBOLI ON LUNG FLUID AND PROTEIN EXCHANGE [J].
JOHNSON, A ;
MALIK, AB .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (02) :461-464
[9]   Cardiac arrest associated with use of an argon beam coagulator during laparoscopic cholecystectomy [J].
Kono, M ;
Yahagi, N ;
Kitahara, M ;
Fujiwara, Y ;
Sha, M ;
Ohmura, A .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (04) :644-646
[10]   Comparison of the effects of controlled ventilation with 100% oxygen, 50% oxygen in nitrogen, and 50% oxygen in nitrous oxide on responses to venous air embolism in pigs [J].
Kytta, J ;
Tanskanen, P ;
Randell, T .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (05) :658-661