A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures

被引:74
作者
Liporace, FA [1 ]
Gupta, S [1 ]
Jeong, GK [1 ]
Stracher, M [1 ]
Kummer, F [1 ]
Egol, KA [1 ]
Koval, KJ [1 ]
机构
[1] NYU, Hosp Joint Dis, New York, NY USA
关键词
distal radius fracture; volar plate; dorsal plate;
D O I
10.1097/00005131-200503000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To compare the biomechanical stability of internal fixation of extra-articular, dorsally unstable distal radius fractures fixed by 1 of 2 methods, either a standard dorsal nonlocked T-plate or a volar locked fixed-angle plate. Design: Biomechanical cadaveric study. Setting: Biomechanical testing laboratory. Intervention: In 6 matched pairs of fresh-frozen cadaveric specimens, a simulated unstable extra-articular distal radius fracture was created. The fractures were stabilized with either a dorsal 3.5-mm stainless steel T-plate or a titanium locked volar fixed-angle plate. Specimens were axially loaded at 5 points (centrally, volarly, dorsally, radially, and ulnarly) and then cyclically loaded for 5000 cycles with an 80 N central load. Postcyclical loading, specimens were once again axially loaded at the 5 points. Main Outcome Measures: Initial fixation stiffness and stiffness after midaxial cyclical loading was compared at the 5 points. Results: With the volar locked fixed-angle plate, fixation was significantly stiffer than with the dorsal nonlocked T-plate for ulnar and volar loading in single-cycle testing. After cyclic loading, the locked volar fixed-angle plate maintained more of its initial stiffness than the dorsal nonlocked T-plate. The dorsal 3.5-mm stainless steel T-plate's stiffness when dorsally loaded significantly decreased after cyclical loading. Conclusions: The volar locked fixed-angle plate maintained a greater percentage of its initial stiffness after cyclic loading compared to the dorsal nonlocked plate. Also, the volar locked plate was stiffer than the dorsal nonlocked plate for all loading configurations tested except when subjected to a dorsally applied eccentric load.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 32 条
[1]   OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]   OPEN REDUCTION AND INTERNAL-FIXATION OF DISPLACED, COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS [J].
BRADWAY, JK ;
AMADIO, PC ;
COONEY, WP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06) :839-847
[3]   RELATIVE TENSION AND POTENTIAL EXCURSION OF MUSCLES IN THE FOREARM AND HAND [J].
BRAND, PW ;
THOMPSON, DE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :209-219
[4]   Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[5]   THE VALUE OF EARLY MOBILIZATION IN THE TREATMENT OF COLLES FRACTURES [J].
DIAS, JJ ;
WRAY, CC ;
JONES, JM ;
GREGG, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (03) :463-467
[6]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[7]  
Dumont C, 2003, CHIRURG, V74, P827, DOI 10.1007/s00104-003-0667-x
[8]  
Dunning CE, 1999, J HAND SURG-AM, V24A, P992
[9]  
FERNANDEZ DL, 1993, AAOS INSTR COURSE LE, V42, P73
[10]  
GEORGOULIS A, 1992, Aktuelle Traumatologie, V22, P9