Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration

被引:12
作者
Maines, Massimiliano [1 ]
Catanzariti, Domenico [1 ]
Cirrincione, Carlo [1 ]
Valsecchi, Sergio [2 ]
Comisso, Jennifer [2 ]
Vergara, Giuseppe [1 ]
机构
[1] Santa Maria del Carmine Hosp, Div Cardiol, I-38068 Rovereto, TN, Italy
[2] Medtron Italia, Rome, Italy
来源
EUROPACE | 2010年 / 12卷 / 05期
关键词
Heart failure; Intrathoracic impedance; Implantable defibrillator; Pulmonary wedge pressure; IMPLANTABLE HEMODYNAMIC MONITOR; FILLING PRESSURES; MANAGEMENT; HOSPITALIZATIONS; DEFIBRILLATOR; MULTICENTER; DIAGNOSIS; THERAPY; ATRIAL;
D O I
10.1093/europace/eup419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aims of this analysis were to assess the agreement between implantable defibrillator (ICD)-measured intrathoracic impedance and pulmonary capillary wedge pressure (PCWP) collected during long-term follow-up, as well as to evaluate whether PCWP measures may improve the performance of the impedance detection algorithm in predicting heart failure (HF) worsening. We studied 23 HF patients implanted with an ICD capable of intrathoracic impedance measurement and alerting for fluid accumulation diagnosis. At regular follow-up and at visits for HF decompensation or device alert, clinical status was assessed and PCWP was non-invasively estimated with a validated echo-Doppler method. During 23 +/- 11 months, 45 paired assessments of impedance and PCWP were performed. The Kappa analysis revealed good agreement between impedance and PCWP (k = 0.701, SE 0.113, P < 0.001). Moreover, PCWP estimations and the paired values of the impedance fluid index resulted significantly correlated (r = 0.677, P < 0.001). The impedance-alert detected clinical HF deterioration with 92% sensitivity and 69% positive predictive value. The combined finding of decreased impedance and increased PCWP resulted in enhanced positive predictive value (92%) and no change in sensitivity (92%). These data confirm the inverse correlation between impedance and PCWP at long-term follow-up and suggest the potential clinical value of a combined impedance and pressure assessment for the improved detection of HF deterioration.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 25 条
[1]   Ongoing right ventricular hemodynarnics in heart failure -: Clinical value of measurements derived from an implantable monitoring system [J].
Adamson, PB ;
Magalski, A ;
Braunschweig, F ;
Böhm, M ;
Reynolds, D ;
Steinhaus, D ;
Luby, A ;
Linde, C ;
Ryden, L ;
Cremers, B ;
Takle, T ;
Bennett, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (04) :565-571
[2]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[3]  
CAMPANA C, 1993, J HEART LUNG TRANSPL, V12, P756
[4]   Monitoring Intrathoracic Impedance with an Implantable Defibrillator Reduces Hospitalizations in Patients with Heart Failure [J].
Catanzariti, Domenico ;
Lunati, Maurizio ;
Landolina, Maurizio ;
Zanotto, Gabriele ;
Lonardi, Gabriele ;
Iacopino, Saverio ;
Oliva, Fabrizio ;
Perego, Giovanni B. ;
Varbaro, Annamaria ;
Denaro, Alessandra ;
Valsecchi, Sergio ;
Vergara, Giuseppe .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (03) :363-370
[5]   Impact of a comprehensive heart failure management program on hospital readmission and functional status of patients with advanced heart failure [J].
Fonarow, GC ;
Stevenson, LW ;
Walden, JA ;
Livingston, NA ;
Steimle, AE ;
Hamilton, MA ;
Moriguchi, J ;
Tillisch, JH ;
Woo, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :725-732
[6]   PULMONARY VERSUS SYSTEMIC HEMODYNAMICS IN DETERMINING EXERCISE CAPACITY OF PATIENTS WITH CHRONIC LEFT-VENTRICULAR FAILURE [J].
FRANCIOSA, JA ;
BAKER, BJ ;
SETH, L .
AMERICAN HEART JOURNAL, 1985, 110 (04) :807-813
[7]   ACCURACY OF LEFT ATRIAL AND PULMONARY-ARTERY WEDGE PRESSURE IN PURE MITRAL REGURGITATION IN PREDICTING LEFT-VENTRICULAR END-DIASTOLIC PRESSURE [J].
HASKELL, RJ ;
FRENCH, WJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (01) :136-141
[8]  
Hunt SA, 2005, CIRCULATION, V112, pE154, DOI [10.1161/CIRCULATIONAHA.105.167586, 10.1161/CIRCULATIONAHA.105.167587]
[9]   Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor:: A multicenter, 12-month follow-up study of patients with chronic heart failure [J].
Magalski, A ;
Adamson, P ;
Gadler, F ;
Böehm, M ;
Steinhaus, D ;
Reynolds, D ;
Vlach, K ;
Linde, C ;
Cremers, B ;
Sparks, B ;
Bennett, T .
JOURNAL OF CARDIAC FAILURE, 2002, 8 (02) :63-70
[10]   Usefulness of intrathoracic fluids accumulation monitoring with an implantable biventricular defibrillator in reducing hospitalizations in patients with heart failure: A case-control study [J].
Maines, Massimiliano ;
Catanzariti, Domenico ;
Cemin, Claudio ;
Vaccarini, Chiara ;
Vergara, Giuseppe .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2007, 19 (03) :201-207