An improved MR sequence for attenuation correction in PET/MR hybrid imaging

被引:2
作者
Sagiyama, Koji [1 ]
Watanabe, Yuji [2 ]
Kamei, Ryotaro [1 ]
Shinyama, Daiki [3 ]
Baba, Shingo [1 ]
Honda, Hiroshi [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka 812, Japan
[2] Kyushu Univ, Grad Sch Med Sci, Dept Mol Imaging & Diag, Fukuoka 812, Japan
[3] Philips Elect Japan, Tokyo, Japan
关键词
PET/MR; Attenuation correction; Radial k-space sampling; MR sequence; Tissue segmentation; WHOLE-BODY PET/MRI; SEGMENTATION; ARTIFACTS;
D O I
10.1016/j.mri.2015.10.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate the effects of MR parameters on tissue segmentation and determine the optimal MR sequence for attenuation correction in PET/MR hybrid imaging. Eight healthy volunteers were examined using a PET/MR hybrid scanner with six three-dimensional turbo-field-echo sequences for attenuation correction by modifying the echo time, k-space trajectory in the phase-encoding direction, and image contrast. MR images for attenuation correction were obtained from six MR sequences in each session; each volunteer underwent four sessions. Two radiologists assessed the attenuation correction maps generated from the MR images with respect to segmentation errors and ghost artifacts on a five-point scale, and the scores were decided by consensus. Segmentation accuracy and reproducibility were compared. Multiple regression analysis was performed to determine the effects of each MR parameter. The two three-dimensional turbo-field-echo sequences with an in-phase echo time and radial k-space sampling showed the highest total scores for segmentation accuracy, with a high reproducibility. In multiple regression analysis, the score with the shortest echo time (-3.44, P < 0.0001) and Cartesian sampling in the anterior/posterior phase-encoding direction (-2.72, P = 0.002) was significantly lower than that with in-phase echo time and Cartesian sampling in the right/left phase-encoding direction. Radial k-space sampling provided a significantly higher score (+5.08, P < 0.0001) compared with Cartesian sampling. Furthermore, radial sampling improved intrasubject variations in the segmentation score (-828%, P = 0.002). Image contrast had no significant effect on the total score or reproducibility. These results suggest that three-dimensional turbo-field-echo MR sequences with an in-phase echo time and radial k-space sampling provide improved MR-based attenuation correction maps. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 2010, MRI BASICS
[2]   Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MR [J].
Arabi, Hossein ;
Rager, Olivier ;
Alem, Asma ;
Varoquaux, Arthur ;
Becker, Minerva ;
Zaidi, Habib .
MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (02) :264-276
[3]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[4]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[5]  
Bini J, 2012, SIGN PROC MED BIOL S
[6]   Segmentation-Based Attenuation Correction in Positron Emission Tomography/Magnetic Resonance Erroneous Tissue Identification and Its Impact on Positron Emission Tomography Interpretation [J].
Brendle, Cornelia ;
Schmidt, Holger ;
Oergel, Anja ;
Bezrukov, Ilja ;
Mueller, Mark ;
Schraml, Christina ;
Pfannenberg, Christina ;
la Fougere, Christian ;
Nikolaou, Konstantin ;
Schwenzer, Nina .
INVESTIGATIVE RADIOLOGY, 2015, 50 (05) :339-346
[7]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[8]   Anatomic Evaluation of 3-Dimensional Ultrashort-Echo-Time Bone Maps for PET/MR Attenuation Correction [J].
Delso, Gaspar ;
Carl, Michael ;
Wiesinger, Florian ;
Sacolick, Laura ;
Porto, Miguel ;
Huellner, Martin ;
Boss, Andreas ;
Veit-Haibach, Patrick .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (05) :780-785
[9]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[10]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883