Failure of corn trypsin inhibitor to affect the thrombin generation assay in plasma from severe hemophiliacs

被引:16
作者
Mohammed, B. M. [1 ,2 ]
Martin, E. J. [1 ]
Salinas, V. [3 ]
Carmona, R. [3 ]
Young, G. [3 ]
Brophy, D. F. [1 ]
机构
[1] Virginia Commonwealth Univ, Coagulat Adv Lab, Dept Pharmacotherapy & Outcomes Sci, Richmond, VA 23298 USA
[2] Cairo Univ, Dept Clin Pharm, Fac Pharm, Cairo, Egypt
[3] Univ So Calif, Keck Sch Med, Ctr Thrombosis & Hemostasis, Div Hematol Oncol,Childrens Hosp Los Angeles, Los Angeles, CA 90033 USA
关键词
corn trypsin inhibitor; hemophilia; inhibitors; patient monitoring; thrombin; CALIBRATED AUTOMATED THROMBOGRAPHY; TISSUE FACTOR; GLOBAL HEMOSTASIS; CONTACT FACTOR; STANDARDIZATION;
D O I
10.1111/jth.12659
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe thrombin generation assay (TGA) is an important global coagulation assay; however, it suffers from the lack of preanalytical standardization. The addition of corn trypsin inhibitor (CTI) to blood collection tubes before TGA has been previously advocated to block the contact activation pathway. Emerging data, however, suggest that CTI may only be necessary when minimal tissue factor (TF) concentrations <1pmol are used. ObjectivesTo determine whether blood collection tubes containing CTI influenced TGA parameters. MethodsThis cross-sectional, observational study performed the TGA using TF 1 pmol L-1 in 15 healthy volunteers, 14 severely factor VIII (FVIII)-deficient patients, and 15 severely FVIII-deficient patients with documented FVIII inhibitors. TGA was conducted using blood tubes that contained CTI 33gmL(-1) and no CTI. ResultsCTI markedly reduced peak thrombin (P=0.002) and endogenous thrombin potential (P<0.001) in the healthy volunteers but had no significant effect on TGA parameters in severely FVIII-deficient patients or those with inhibitors. ConclusionsThis lack of effect raises additional questions regarding the need for CTI as a preanalytical addition to blood collection tubes during TGA in severe hemophiliacs, particularly when activating samples with TF 1pmol L-1.
引用
收藏
页码:1558 / 1561
页数:4
相关论文
共 15 条
[1]   Monitoring rFVIII prophylaxis dosing using global haemostasis assays [J].
AL Hawaj, M. A. ;
Martin, E. J. ;
Venitz, J. ;
Barrett, J. C. ;
Kuhn, J. G. ;
Nolte, M. E. ;
Brophy, D. F. .
HAEMOPHILIA, 2013, 19 (03) :409-414
[2]   Towards a recommendation for the standardization of the measurement of platelet-dependent thrombin generation [J].
Baglin, T. ;
Besser, M. ;
Cattaneo, M. ;
Dargaud, Y. ;
Gray, E. ;
Key, N. S. ;
Lecompte, T. ;
Luddington, R. ;
Petros, S. ;
Siegemund, T. ;
Wolberg, A. S. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (09) :1859-1861
[3]   Thrombin generation and phenotypic correlation in haemophilia A [J].
Beltrán-Miranda, CP ;
Khan, A ;
Jaloma-Cruz, AR ;
Laffan, MA .
HAEMOPHILIA, 2005, 11 (04) :326-334
[4]   Contact activation: important to consider when measuring the contribution of tissue factor-bearing microparticles to thrombin generation using phospholipid-containing reagents [J].
Boknas, N. ;
Faxalv, L. ;
Lindahl, T. L. ;
Ramstrom, S. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2014, 12 (04) :515-518
[5]   Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor [J].
Dargaud, Y ;
Luddington, R ;
Baglin, TP .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (05) :1160-1161
[6]   Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study [J].
Dargaud, Yesim ;
Luddington, Rodger ;
Gray, Elaine ;
Negrier, Claude ;
Lecompte, Thomas ;
Petros, Sirak ;
Hogwood, John ;
Bordet, Jean-Claude ;
Hogwood, John ;
Bordet, Jean-Claude ;
Regnault, Veronique ;
Siegemund, Annelie ;
Baglin, Trevor .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 139 (02) :303-309
[7]   Prospective assessment of thrombin generation test for dose monitoring of bypassing therapy in hemophilia patients with inhibitors undergoing elective surgery [J].
Dargaud, Yesim ;
Lienhart, Anne ;
Negrier, Claude .
BLOOD, 2010, 116 (25) :5734-5737
[8]  
Haematologic Technologies Inc, CORN TRYPS INH BLOOD
[9]   Calibrated automated thrombin generation measurement in clotting plasma [J].
Hemker, HC ;
Giesen, P ;
Al Dieri, R ;
Regnault, V ;
de Smedt, E ;
Wagenvoord, R ;
Lecompte, T ;
Béguin, S .
PATHOPHYSIOLOGY OF HAEMOSTASIS AND THROMBOSIS, 2003, 33 (01) :4-15
[10]   Measurement of global haemostasis in severe haemophilia A following factor VIII infusion [J].
Lewis, S. J. ;
Stephens, E. ;
Florou, G. ;
Macartney, N. J. ;
Hathaway, L. S. ;
Knipping, J. ;
Collins, P. W. .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 138 (06) :775-782