Robustness of optimal energy thresholds in photon-counting spectral CT

被引:14
作者
Zheng, Yifan [1 ,2 ,3 ]
Yveborg, Moa [4 ]
Gronberg, Fredrik [1 ]
Xu, Cheng [1 ,4 ]
Su, Qianqian [2 ,3 ]
Danielsson, Mats [1 ,4 ]
Persson, Mats [1 ,5 ,6 ]
机构
[1] Albanova Univ Ctr, Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
[2] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[4] Prismat Sensors AB, Roslagstullsbacken 21, S-10691 Stockholm, Sweden
[5] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
Photon counting; Spectral CT; Threshold optimization; Silicon-strip detector; CZT detector; SILICON-STRIP DETECTOR; FEASIBILITY; STATISTICS; RESOLUTION;
D O I
10.1016/j.nima.2019.163132
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An important question when developing photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing signal-difference-to-noise ratio squared (SDNR2) in an optimally weighted image and signal-to-noise ratio squared (SNR2) in a gadolinium basis image in a silicon-strip detector and a cadmium zinc telluride (CZT) detector, factoring in pileup and imperfect energy response based on real-world detector systems. To investigate to what extent one single set of thresholds could be applied in various imaging tasks, the robustness of optimal thresholds with 2 to 8 bins is examined with the variation of phantom thicknesses, target materials and detector configurations. In contrast to previous studies, the optimal threshold locations do not always increase with increasing attenuation if pileup is included. With respect to the tradeoff between higher SDNR2 or SNR2 and less data, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 and setting optimal thresholds for a 50 cm phantom yields robust SNR2 with 6 to 8 bins in the silicon-strip detector. Furthermore, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 or SNR2 with 6 to 8 bins and a pixel size less than or equal to 0.5 x 0.5 mm(2) in the CZT detector.
引用
收藏
页数:19
相关论文
共 40 条
  • [1] [Anonymous], INVESTIG RADIOL
  • [2] [Anonymous], MED PHYS
  • [3] [Anonymous], NUCL INSTRUM METHODS
  • [4] [Anonymous], SPIE MED IMAGING
  • [5] [Anonymous], 2017, Med. Phys
  • [6] [Anonymous], MED IMAGING 2010 PHY
  • [7] [Anonymous], MEDIEV WOR
  • [8] The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging
    Ballabriga, R.
    Alozy, J.
    Blaj, G.
    Campbell, M.
    Fiederle, M.
    Frojdh, E.
    Heijne, E. H. M.
    Llopart, X.
    Pichotka, M.
    Procz, S.
    Tlustos, L.
    Wong, W.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [9] Barrett HH., 2013, FDN IMAGE SCI
  • [10] Task-based weights for photon counting spectral x-ray imaging
    Bornefalk, Hans
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6065 - 6073