An in vitro verification of strength estimation for moving an 125I source during implantation in brachytherapy

被引:3
作者
Tanaka, Kenichi [1 ]
Kajimoto, Tsuyoshi [1 ]
Hayashi, Takahiro [1 ]
Asanuma, Osamu [2 ]
Hori, Masakazu [3 ]
Kamo, Ken-ichi [3 ]
Sumida, Iori [4 ]
Takahashi, Yutaka [4 ]
Tateoka, Kunihiko [3 ]
Bengua, Gerard [5 ]
Sakata, Koh-ichi [3 ]
Endo, Satoru [1 ]
机构
[1] Hiroshima Univ, Grad Sch Engn, Quantum Energy Applicat, 1-4-1 Kagamiyama, Higashihiroshima, Hiroshima 7398527, Japan
[2] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Chuo Ward, South 1,West 17, Sapporo, Hokkaido 0608556, Japan
[3] Sapporo Med Univ, Grad Sch Med, Dept Radiat Oncol, Chuo Ward, South 1,West 16, Sapporo, Hokkaido 0608543, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[5] Auckland City Hosp, Pk Rd, Auckland 1142, New Zealand
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
brachytherapy; I-125; source strength; moving source; verification; INTERSTITIAL BRACHYTHERAPY; DOSIMETRY;
D O I
10.1093/jrr/rry021
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to demonstrate the feasibility of a method for estimating the strength of a moving brachytherapy source during implantation in a patient. Experiments were performed under the same conditions as in the actual treatment, except for one point that the source was not implanted into a patient. The brachytherapy source selected for this study was I-125 with an air kerma strength of 0.332 U (mu Gym(2)h(-1)), and the detector used was a plastic scintillator with dimensions of 10 cm x 5 cm x 5 cm. A calibration factor to convert the counting rate of the detector to the source strength was measured and then the accuracy of the proposed method was investigated for a manually driven source. The accuracy was found to be under 10% when the shielding effect of additional needles for implantation at other positions was corrected, and about 30% when the shielding was not corrected. Even without shielding correction, the proposed method can detect dead/dropped source, implantation of a source with the wrong strength, and a mistake in the number of the sources implanted. Furthermore, when the correction was applied, the achieved accuracy came close to within 7% required to find the Oncoseed 6711 (I-125 seed with unintended strength among the commercially supplied values of 0.392, 0.462 and 0.533 U).
引用
收藏
页码:484 / 489
页数:6
相关论文
共 12 条
  • [1] Third-party brachytherapy source calibrations and physicist responsibilities: Report of the AAPM Low Energy Brachytherapy Source Calibration Working Group
    Butler, Wayne M.
    Bice, William S., Jr.
    DeWerd, Larry A.
    Hevezi, James M.
    Huq, M. Saiful
    Ibbott, Geoffrey S.
    Palta, Jatinder R.
    Rivard, Mark J.
    Seuntjens, Jan P.
    Thomadsen, Bruce R.
    [J]. MEDICAL PHYSICS, 2008, 35 (09) : 3860 - 3865
  • [2] Comparison of Implant Quality between Loose and Intra-operatively Linked Iodine-125 Seeds in Prostate Cancer Brachytherapy
    Jarusevicius, Laimonas
    Inciura, Arturas
    Juozaityte, Elona
    Vaiciunas, Kestutis
    Vaitkus, Antanas
    Sniureviciute, Migle
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (03) : 439 - 446
  • [3] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234
  • [4] Ohno T, 2016, J RADIAT RES, V53, P1
  • [5] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [6] High-dose-rate Interstitial Brachytherapy with Computed Tomography-based Treatment Planning for Patients with Locally Advanced Uterine Cervical Carcinoma
    Saitoh, Jun-ichi
    Ohno, Tatsuya
    Sakurai, Hideyuki
    Katoh, Hiroyuki
    Wakatsuki, Masaru
    Noda, Shin-ei
    Suzuki, Yoshiyuki
    Sibuya, Kei
    Takahashi, Takeo
    Nakano, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2011, 52 (04) : 490 - 495
  • [7] Tanaka K, 2012, JPN J MED PHYS, V32, P192
  • [8] Strength estimation of a moving 125Iodine source during implantation in brachytherapy: application to linked sources
    Tanaka, Kenichi
    Endo, Satoru
    Tateoka, Kunihiko
    Asanuma, Osamu
    Hori, Masakazu
    Takagi, Masaru
    Bengua, Gerard
    Kamo, Ken-ichi
    Sato, Kaori
    Takeda, Hiromitsu
    Hareyama, Masato
    Sakata, Koh-ichi
    Takada, Jun
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1146 - 1152
  • [9] A dosimetry method for low dose rate brachytherapy by EGS5 combined with regression to reflect source strength shortage
    Tanaka, Kenichi
    Tateoka, Kunihiko
    Asanuma, Osamu
    Kamo, Ken-ichi
    Sato, Kaori
    Takeda, Hiromitsu
    Takagi, Masaru
    Hareyama, Masato
    Takada, Jun
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (03) : 608 - 612
  • [10] Measurement of the strength of iodine-125 seed moving at unknown speed during implantation in brachytherapy
    Tanaka, Kenichi
    Endo, Satoru
    Tateoka, Kunihiko
    Asanuma, Osamu
    Kamo, Ken-ichi
    Sato, Kaori
    Takeda, Hiromitsu
    Takagi, Masaru
    Hareyama, Masato
    Takada, Jun
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 162 - 167