An in vitro verification of strength estimation for moving an 125I source during implantation in brachytherapy

被引:3
作者
Tanaka, Kenichi [1 ]
Kajimoto, Tsuyoshi [1 ]
Hayashi, Takahiro [1 ]
Asanuma, Osamu [2 ]
Hori, Masakazu [3 ]
Kamo, Ken-ichi [3 ]
Sumida, Iori [4 ]
Takahashi, Yutaka [4 ]
Tateoka, Kunihiko [3 ]
Bengua, Gerard [5 ]
Sakata, Koh-ichi [3 ]
Endo, Satoru [1 ]
机构
[1] Hiroshima Univ, Grad Sch Engn, Quantum Energy Applicat, 1-4-1 Kagamiyama, Higashihiroshima, Hiroshima 7398527, Japan
[2] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Chuo Ward, South 1,West 17, Sapporo, Hokkaido 0608556, Japan
[3] Sapporo Med Univ, Grad Sch Med, Dept Radiat Oncol, Chuo Ward, South 1,West 16, Sapporo, Hokkaido 0608543, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[5] Auckland City Hosp, Pk Rd, Auckland 1142, New Zealand
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
brachytherapy; I-125; source strength; moving source; verification; INTERSTITIAL BRACHYTHERAPY; DOSIMETRY;
D O I
10.1093/jrr/rry021
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to demonstrate the feasibility of a method for estimating the strength of a moving brachytherapy source during implantation in a patient. Experiments were performed under the same conditions as in the actual treatment, except for one point that the source was not implanted into a patient. The brachytherapy source selected for this study was I-125 with an air kerma strength of 0.332 U (mu Gym(2)h(-1)), and the detector used was a plastic scintillator with dimensions of 10 cm x 5 cm x 5 cm. A calibration factor to convert the counting rate of the detector to the source strength was measured and then the accuracy of the proposed method was investigated for a manually driven source. The accuracy was found to be under 10% when the shielding effect of additional needles for implantation at other positions was corrected, and about 30% when the shielding was not corrected. Even without shielding correction, the proposed method can detect dead/dropped source, implantation of a source with the wrong strength, and a mistake in the number of the sources implanted. Furthermore, when the correction was applied, the achieved accuracy came close to within 7% required to find the Oncoseed 6711 (I-125 seed with unintended strength among the commercially supplied values of 0.392, 0.462 and 0.533 U).
引用
收藏
页码:484 / 489
页数:6
相关论文
共 12 条
[1]   Third-party brachytherapy source calibrations and physicist responsibilities: Report of the AAPM Low Energy Brachytherapy Source Calibration Working Group [J].
Butler, Wayne M. ;
Bice, William S., Jr. ;
DeWerd, Larry A. ;
Hevezi, James M. ;
Huq, M. Saiful ;
Ibbott, Geoffrey S. ;
Palta, Jatinder R. ;
Rivard, Mark J. ;
Seuntjens, Jan P. ;
Thomadsen, Bruce R. .
MEDICAL PHYSICS, 2008, 35 (09) :3860-3865
[2]   Comparison of Implant Quality between Loose and Intra-operatively Linked Iodine-125 Seeds in Prostate Cancer Brachytherapy [J].
Jarusevicius, Laimonas ;
Inciura, Arturas ;
Juozaityte, Elona ;
Vaiciunas, Kestutis ;
Vaitkus, Antanas ;
Sniureviciute, Migle .
JOURNAL OF RADIATION RESEARCH, 2012, 53 (03) :439-446
[3]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[4]  
Ohno T, 2016, J RADIAT RES, V53, P1
[5]   Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].
Rivard, MJ ;
Coursey, BM ;
DeWerd, LA ;
Hanson, WF ;
Huq, MS ;
Ibbott, GS ;
Mitch, MG ;
Nath, R ;
Williamson, JF .
MEDICAL PHYSICS, 2004, 31 (03) :633-674
[6]   High-dose-rate Interstitial Brachytherapy with Computed Tomography-based Treatment Planning for Patients with Locally Advanced Uterine Cervical Carcinoma [J].
Saitoh, Jun-ichi ;
Ohno, Tatsuya ;
Sakurai, Hideyuki ;
Katoh, Hiroyuki ;
Wakatsuki, Masaru ;
Noda, Shin-ei ;
Suzuki, Yoshiyuki ;
Sibuya, Kei ;
Takahashi, Takeo ;
Nakano, Takashi .
JOURNAL OF RADIATION RESEARCH, 2011, 52 (04) :490-495
[7]  
Tanaka K, 2012, JPN J MED PHYS, V32, P192
[8]   Strength estimation of a moving 125Iodine source during implantation in brachytherapy: application to linked sources [J].
Tanaka, Kenichi ;
Endo, Satoru ;
Tateoka, Kunihiko ;
Asanuma, Osamu ;
Hori, Masakazu ;
Takagi, Masaru ;
Bengua, Gerard ;
Kamo, Ken-ichi ;
Sato, Kaori ;
Takeda, Hiromitsu ;
Hareyama, Masato ;
Sakata, Koh-ichi ;
Takada, Jun .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) :1146-1152
[9]   A dosimetry method for low dose rate brachytherapy by EGS5 combined with regression to reflect source strength shortage [J].
Tanaka, Kenichi ;
Tateoka, Kunihiko ;
Asanuma, Osamu ;
Kamo, Ken-ichi ;
Sato, Kaori ;
Takeda, Hiromitsu ;
Takagi, Masaru ;
Hareyama, Masato ;
Takada, Jun .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (03) :608-612
[10]   Measurement of the strength of iodine-125 seed moving at unknown speed during implantation in brachytherapy [J].
Tanaka, Kenichi ;
Endo, Satoru ;
Tateoka, Kunihiko ;
Asanuma, Osamu ;
Kamo, Ken-ichi ;
Sato, Kaori ;
Takeda, Hiromitsu ;
Takagi, Masaru ;
Hareyama, Masato ;
Takada, Jun .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) :162-167