IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept

被引:16
作者
Zabat, Mahdi [1 ]
Ababou, Amina [1 ]
Ababou, Noureddine [1 ]
Dumas, Raphael [2 ]
机构
[1] Univ Sci & Technol Houari Boumediene, Lab Instrumentat, BP 32 El Alia, Bab Ezzouar Algiers 16111, Algeria
[2] Univ Claude Bernard Lyon 1, Univ Lyon, IFSTTAR, LBMC UMR T9406, 43 Blvd,11 Novembre 1918, F-69622 Villeurbanne, France
关键词
Joint angle; IMU measurement; Posture; Calibration; Soft tissue artifact; SOFT-TISSUE ARTIFACT; HUMAN MOVEMENT ANALYSIS; ANATOMICAL LANDMARK CALIBRATION; INERTIAL MEASUREMENT UNITS; AMBULATORY MEASUREMENT; MOTION CAPTURE; KINEMATICS; MODEL; ELBOW; REPEATABILITY;
D O I
10.1007/s11517-019-02033-7
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A lot of attention has been paid to wearable inertial sensors regarded as an alternative solution for outdoor human motion tracking. Relevant joint angles can only be calculated from anatomical orientations, but they are negatively impacted by soft tissue artifact (STA) defined as skin motion with respect to the underlying bone; the accuracy of measured joint angle during movement is affected by the ongoing misalignment of the sensor. In this work, a new sensor-to-segment calibration using inertial measurement units is proposed. Inspired by the multiple calibration for a cluster of skin markers, it consists in performing first multiple static postures of the upper limb in all anatomical planes. The movements that affect sensor alignment are identified then alignment differences between sensors and segment frames are calculated for each posture and linearly interpolated. Experimental measurements were carried out on a mechanical model and on a subject who performed different movements of right elbow and shoulder. Multiple calibration showed significant improvement in joint angle measurement on the mechanical model as well as on human joint angle comparing to those obtained from attached sensors after technical calibration. During shoulder internal-external rotation, the maximal error value decreased more than 50% after correction.
引用
收藏
页码:2449 / 2460
页数:12
相关论文
共 45 条
[41]   Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis [J].
Robert-Lachaine, Xavier ;
Mecheri, Hakim ;
Larue, Christian ;
Plamondon, Andre .
GAIT & POSTURE, 2017, 54 :80-86
[42]  
Rowe PJ., 2001, Physiother, V87, P479, DOI DOI 10.1016/S0031-9406(05)60695-5
[43]  
Taetz B, 2016, 2016 19TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION (FUSION), P1751
[44]   An IMU-to-Body Alignment Method Applied to Human Gait Analysis [J].
Vargas-Valencia, Laura Susana ;
Elias, Arlindo ;
Rocon, Eduardo ;
Bastos-Filho, Teodiano ;
Frizera, Anselmo .
SENSORS, 2016, 16 (12)
[45]   ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand [J].
Wu, G ;
van der Helm, FCT ;
Veeger, HEJ ;
Makhsous, M ;
Van Roy, P ;
Anglin, C ;
Nagels, J ;
Karduna, AR ;
McQuade, K ;
Wang, XG ;
Werner, FW ;
Buchholz, B .
JOURNAL OF BIOMECHANICS, 2005, 38 (05) :981-992