The development of a magnetic resonance imaging index for fistulising Crohn's disease

被引:57
|
作者
Samaan, M. A. [1 ,2 ]
Puylaert, C. A. J. [3 ]
Levesque, B. G. [4 ,5 ]
Zou, G. Y. [2 ,6 ]
Stitt, L. [2 ]
Taylor, S. A. [7 ]
Shackelton, L. M. [2 ]
Vandervoort, M. K. [2 ]
Khanna, R. [2 ,8 ]
Santillan, C. [9 ]
Rimola, J. [10 ]
Hindryckx, P. [2 ,11 ]
Nio, C. Y. [3 ]
Sandborn, W. J. [4 ,5 ]
D'Haens, G. [12 ,13 ]
Feagan, B. G. [2 ,6 ,8 ]
Jairath, V. [2 ,6 ,8 ]
Stoker, J. [3 ]
机构
[1] Guys & St Thomas Hosp, Dept Gastroenterol, London, England
[2] Robarts Clin Trials Inc, London, ON, Canada
[3] Acad Med Ctr, Dept Radiol, Amsterdam, Netherlands
[4] Univ Calif San Diego, Dept Gastroenterol, La Jolla, CA 92093 USA
[5] Robarts Clin Trials Inc, San Diego, CA USA
[6] Univ Western Ontario, Dept Epidemiol & Biostat, London, ON, Canada
[7] UCL, Dept Med Imaging, London, England
[8] Univ Western Ontario, Dept Med, London, ON, Canada
[9] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[10] Hosp Clin Barcelona, Dept Radiol, Barcelona, Spain
[11] Univ Hosp Ghent, Dept Gastroenterol, Ghent, Belgium
[12] Acad Med Ctr, Dept Gastroenterol, Amsterdam, Netherlands
[13] Robarts Clin Trials BV, Amsterdam, Netherlands
关键词
COMPLEX PERIANAL FISTULAS; RELIABILITY; CLASSIFICATION; GUIDELINES; INFLIXIMAB; CONSENSUS; MRI;
D O I
10.1111/apt.14190
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Magnetic resonance imaging (MRI) is the gold standard for assessment of perianal fistulising Crohn's disease (CD). The Van Assche index is the most commonly used MRI fistula index. Aims: To assess the reliability of the Van Assche index, and to modify the instrument to improve reliability and create a novel index for fistulising CD. Methods: A consensus process developed scoring conventions for existing Van Assche index component items and new items. Four experienced radiologists evaluated 50 MRI images in random order on three occasions. Reliability was assessed by estimates of intraclass correlation coefficients (ICCs). Common sources of disagreement were identified and recommendations made to minimise disagreement. A mixed effects model used a 100 mm visual anologue scale (VAS) for global severity as outcome and component items as predictors to create a modified Van Assche index. Results: Intraclass correlation coefficients (95% confidence intervals) for intra-rater reliability of the original and modified Van Assche indices and the VAS were 0.86 (0.81-0.90), 0.90 (0.86-0.93) and 0.86 (0.82-0.89). Corresponding ICCs for inter-rater reliability were 0.66 (0.52-0.76), 0.67 (0.55-0.75) and 0.58 (0.47-0.66). Sources of disagreement included number, location, and extension of fistula tracts, and rectal wall involvement. A modified Van Assche index (range 0-24) was created that included seven component items. Conclusions: Although "almost perfect" intra-rater reliability was observed for the assessment of MRI images for fistulising CD using the Van Assche index, inter-rater reliability was considerably lower. Our modification of this index should result in a more optimal instrument.
引用
收藏
页码:516 / 528
页数:13
相关论文
共 50 条
  • [41] A Model Development Pipeline for Crohn's Disease Severity Assessment from Magnetic Resonance Images
    Schueffler, Peter J.
    Mahapatra, Dwarikanath
    Tielbeek, Jeroen A. W.
    Vos, Franciscus M.
    Makanyanga, Jesica
    Pendse, Doug A.
    Nio, C. Yung
    Stoker, Jaap
    Taylor, Stuart A.
    Buhmann, Joachim M.
    ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 1 - 10
  • [42] Treatment of Crohn's anal fistulas guided by magnetic resonance imaging
    Hermann, Jacek
    Stajgis, Piotr
    Kolodziejczak, Barbara
    Eder, Piotr
    Banasiewicz, Tomasz
    GASTROENTEROLOGY REVIEW-PRZEGLAD GASTROENTEROLOGICZNY, 2019, 14 (01): : 55 - 61
  • [43] Magnetic resonance imaging of Alzheimer's disease
    Lehericy, Stephane
    Marjanska, Malgorzata
    Mesrob, Lilia
    Sarazin, Marie
    Kinkingnehun, Serge
    EUROPEAN RADIOLOGY, 2007, 17 (02) : 347 - 362
  • [44] Magnetic resonance imaging of Alzheimer’s disease
    Stéphane Lehéricy
    Malgorzata Marjanska
    Lilia Mesrob
    Marie Sarazin
    Serge Kinkingnehun
    European Radiology, 2007, 17 : 347 - 362
  • [45] Magnetic resonance imaging may predict deep remission in patients with perianal fistulizing Crohn's disease
    Thomassin, Lucie
    Armengol-Debeir, Laura
    Charpentier, Cloe
    Bridoux, Valerie
    Koning, Edith
    Savoye, Guillaume
    Savoye-Collet, Celine
    WORLD JOURNAL OF GASTROENTEROLOGY, 2017, 23 (23) : 4285 - 4292
  • [46] Magnetic resonance imaging-quantified small bowel motility is a sensitive marker of response to medical therapy in Crohn's disease
    Plumb, A. A.
    Menys, A.
    Russo, E.
    Prezzi, D.
    Bhatnagar, G.
    Vega, R.
    Halligan, S.
    Orchard, T. R.
    Taylor, S. A.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2015, 42 (03) : 343 - 355
  • [47] Quantitative Magnetic Resonance Imaging in Perianal Crohn's Disease at 1.5 and 3.0 T: A Feasibility Study
    Alyami, Ali
    Hoad, Caroline L.
    Tench, Christopher
    Bannur, Uday
    Clarke, Christopher
    Latief, Khalid
    Argyriou, Konstantinos
    Lobo, Alan
    Lung, Philip
    Baldwin-Cleland, Rachel
    Sahnan, Kapil
    Hart, Ailsa
    Limdi, Jimmy K.
    Mclaughlin, John
    Atkinson, David
    Parker, Geoffrey J. M.
    O'Connor, James P. B.
    Little, Ross A.
    Gowland, Penny A.
    Moran, Gordon W.
    DIAGNOSTICS, 2021, 11 (11)
  • [48] Diffusion-weighted magnetic resonance imaging is effective to detect ileocolonic ulcerations in Crohn's disease
    Buisson, A.
    Hordonneau, C.
    Goutte, M.
    Boyer, L.
    Pereira, B.
    Bommelaer, G.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2015, 42 (04) : 452 - 460
  • [49] Development, Validation, and Evaluation of the Pediatric Inflammatory Crohn's Magnetic Resonance Enterography Index From the ImageKids Study
    Focht, Gili
    Cytter-Kuint, Ruth
    Greer, Mary-Louise C.
    Pratt, Li-Tal
    Castro, Denise A.
    Church, Peter C.
    Walters, Thomas D.
    Hyams, Jeffrey
    Navon, Dan
    de Carpi, Javier Martin
    Ruemmele, Frank
    Russell, Richard K.
    Gavish, Matan
    Griffiths, Anne M.
    Turner, Dan
    GASTROENTEROLOGY, 2022, 163 (05) : 1306 - 1320
  • [50] Reliability of Measuring Ileo-Colonic Disease Activity in Crohn's Disease by Magnetic Resonance Enterography
    Jairath, Vipul
    Ordas, Ingrid
    Zou, Guangyong
    Panes, Julian
    Stoker, Jaap
    Taylor, Stuart A.
    Santillan, Cynthia
    Horsthuis, Karin
    Samaan, Mark A.
    Shackelton, Lisa M.
    Stitt, Larry W.
    Hindryckx, Pieter
    Khanna, Reena
    Sandborn, William J.
    D'Haens, Geert
    Feagan, Brian G.
    Levesque, Barrett G.
    Rimola, Jordi
    INFLAMMATORY BOWEL DISEASES, 2018, 24 (02) : 440 - 449