In vivo pink-beam imaging and fast alignment procedure for rat brain lesion microbeam radiation therapy

被引:23
作者
Serduc, Raphael [1 ]
Berruyer, Gilles [1 ]
Brochard, Thierry [1 ]
Renier, Michel [1 ]
Nemoz, Christian [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
synchrotron microbeam radiation therapy; pink-beam imaging; alignment procedure; preclinical brain radiosurgery; CCD FRELON CAMERA; COMPUTED-TOMOGRAPHY; SYNCHROTRON; RADIOSURGERY;
D O I
10.1107/S0909049510006667
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast 50 mu m-accuracy alignment procedure has been developed for the radiosurgery of brain lesions in rats, using microbeam radiation therapy. In vivo imaging was performed using the pink beam (35-60 keV) produced by the ID17 wiggler at the ESRF opened at 120 mm and filtered. A graphical user interface has been developed in order to define the irradiation field size and to position the target with respect to the skull structures observed in X-ray images. The method proposed here allows tremendous time saving by skipping the swap from white beam to monochromatic beam and vice versa. To validate the concept, the somatosensory cortex or thalamus of GAERS rats were irradiated under several ports using this alignment procedure. The magnetic resonance images acquired after contrast agent injection showed that the irradiations were selectively performed in these two expected brain regions. Image-guided microbeam irradiations have therefore been realised for the first time ever, and, thanks to this new development, the ID17 biomedical beamline provides a major tool allowing brain radiosurgery trials on animal patients. (C) 2010 International Union of Crystallography Printed in Singapore - all rights reserved
引用
收藏
页码:325 / 331
页数:7
相关论文
共 32 条
  • [1] Absolute cerebral blood volume and blood flow measurements based on synchrotron radiation quantitative computed tomography
    Adam, JF
    Elleaume, H
    Le Duc, G
    Corde, S
    Charvet, AM
    Troprès, I
    Le Bas, JF
    Estève, F
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2003, 23 (04) : 499 - 512
  • [2] Gadolinium chelate coated gold nanoparticles as contrast agents for both X-ray computed tomography and magnetic resonance imaging
    Alric, Christophe
    Taleb, Jacqueline
    Le Duc, Geraldine
    Mandon, Celine
    Billotey, Claire
    Le Meur-Herland, Alice
    Brochard, Thierry
    Vocanson, Francis
    Janier, Marc
    Perriat, Pascal
    Roux, Stephane
    Tillement, Olivier
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (18) : 5908 - 5915
  • [3] [Anonymous], [No title captured], Patent No. [5,771,270, 5771270]
  • [4] [Anonymous], 2004, RAT BRAIN STEREOTAXI
  • [5] Methacholine and Ovalbumin Challenges Assessed by Forced Oscillations and Synchrotron Lung Imaging
    Bayat, Sam
    Strengell, Satu
    Porra, Liisa
    Janosi, Tibor Z.
    Petak, Ferenc
    Suhonen, Heikki
    Suortti, Pekka
    Hantos, Zoltan
    Sovijarvi, Anssi R. A.
    Habre, Walid
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 180 (04) : 296 - 303
  • [6] Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty
    Bertrand, B
    Estève, F
    Elleaume, H
    Nemoz, C
    Fiedler, S
    Bravin, A
    Berruyer, G
    Brochard, T
    Renier, M
    Machecourt, J
    Thomlinson, W
    Le Bas, JF
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (13) : 1284 - 1291
  • [7] BOUCHET A, 2010, UNPUB
  • [8] New technology enables high precision multislit collimators for microbeam radiation therapy
    Braeuer-Krisch, E.
    Requardt, H.
    Brochard, T.
    Berruyer, G.
    Renier, M.
    Laissue, J. A.
    Bravin, A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (07)
  • [9] Characterization of a tungsten/gas multislit collimator for microbeam radiation therapy at the European Synchrotron Radiation Facility -: art. no. 064303
    Bräuer-Krisch, E
    Bravin, A
    Zhang, L
    Siegbahn, E
    Stepanek, J
    Blattmann, H
    Slatkin, DN
    Gebbers, JO
    Jasmin, M
    Laissue, JA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06)
  • [10] MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
    Bräuer-Krisch, E
    Bravin, A
    Lerch, M
    Rosenfeld, A
    Stepanek, J
    Di Michiel, M
    Laissue, JA
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 583 - 589