Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

被引:5
作者
Leon, Stephanie M. [1 ]
Brateman, Libby F. [2 ]
Wagner, Louis K. [1 ]
机构
[1] Univ Texas Med Sch Houston, Dept Diagnost & Intervent Imaging, Houston, TX 77030 USA
[2] Univ Florida, Dept Radiol, Gainesville, FL 32610 USA
关键词
mammography; scatter correction; image processing; Monte Carlo; CT DOSIMETRY; SCATTER/PRIMARY; MODELS; BREAST; UNITS;
D O I
10.1118/1.4894808
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28-0.51, with absolute differences averaging -0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] American Institute of Physics, 1997, AM I PHYS SUPPL MAT
  • [2] [Anonymous], 2003, MCNP GEN MONT CARL N
  • [3] Scatter/primary in mammography: Comprehensive results
    Boone, JM
    Lindfors, KK
    Cooper, VN
    Seibert, JA
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2408 - 2416
  • [4] Scatter/primary in mammography: Monte Carlo validation
    Boone, JM
    Cooper, VN
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1818 - 1831
  • [5] Grid and slot scan scatter reduction in mammography: Comparison by using Monte Carlo techniques
    Boone, JM
    Seibert, JA
    Tang, CM
    Lane, SM
    [J]. RADIOLOGY, 2002, 222 (02) : 519 - 527
  • [6] Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    Boone, JM
    Fewell, TR
    Jennings, RJ
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1863 - 1874
  • [7] Development and Monte Carlo Analysis of Antiscatter Grids for Mammography
    Boone, John M.
    Makarova, Olga V.
    Zyryanov, Vladislav N.
    Tang, Cha-Mei
    Mancini, Derrick C.
    Moldovan, Nikolaie
    Divan, Ralu
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2002, 1 (06) : 441 - 447
  • [8] CIRS, MAMM PHOT CONS TEST
  • [9] Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) : 4335 - 4359
  • [10] THE COMPUTATION OF SCATTER IN MAMMOGRAPHY BY MONTE-CARLO METHODS
    DANCE, DR
    DAY, GJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (03) : 237 - 247