Therapeutic drug monitoring of tacrolimus in kidney transplantation

被引:5
作者
Bansal, Shyam Bihari [1 ]
机构
[1] Medanta Medicity, Medanta Kidney & Urol Inst, Dept Nephrol & Kidney Transplantat, Gurgaon, Haryana, India
关键词
Drug monitoring; kidney transplant; tacrolimus; TANDEM MASS-SPECTROMETRY; MICROPARTICLE ENZYME-IMMUNOASSAY; UNDER-THE-CURVE; IMMUNOSUPPRESSIVE THERAPY; CALCINEURIN INHIBITORS; ORGAN-TRANSPLANTATION; BLOOD-CONCENTRATIONS; ABCB1; POLYMORPHISMS; DOSE REQUIREMENTS; TROUGH LEVELS;
D O I
10.4103/ijot.ijot_4_20
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Calcineurin inhibitors (CNI) are the backbone of present-day immunosuppressive regimen in kidney transplant recipients. Tacrolimus (TAC) has gradually replaced cyclosporine as CNI of choice due to its better potency and side effect profile. One of the key challenges in using TAC is therapeutic drug monitoring (TDM) of TAC, as it is a drug of narrow therapeutic index. Various methods of TDM are available; there are older immunoassay (IA)-based methods and recent liquid chromatogram (LC) based. The problems with older IAs like microparticle enzyme IA (Abbott Diagnostics, Chicago, IL, USA), and enzyme multiplied IA (EMIT, Dade Behring, Glasgow, DE, USA) are; they are not so accurate, there is interference with other substances, they measure inactive metabolite, and their limit of detection is not wide. The LC-based methods such as liquid chromatogram mass spectroscopy or LC-tandem mass spectroscopy overcome these issues; however, they are costly, labor intensive, and require good technical support. Newer IAs, such as chemiluminescent microparticle IA (Abbott Diagnostics) and Quantitative Microsphere System (QMS (TM), Thermo-Fisher), have functional sensitivity <1 ng/ml, and overcome the disadvantages of older IAs. These newer IA are reported to offer adequate accuracy and precision, and at the same time, they are easy to perform. There is genetic variation in expression of cytochrome p-450 (CYP3A4) and CYP3A5 enzymes, which metabolizes TAC, resulting in different levels with same doses. Patients who are expressers (CYP3A5 1*/1* OR CYP3A5 1*/3*) require higher doses to maintain the same levels compared to nonexpressers (CYP3A5 3*/3*).
引用
收藏
页码:8 / 14
页数:7
相关论文
共 52 条
  • [1] Evaluation of 2 Immunoassays for Monitoring Low Blood Levels of Tacrolimus
    Amann, Shawn
    Parker, Thomas S.
    Levine, Daniel M.
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (02) : 273 - 276
  • [2] Association of the multidrug resistance-1 gene single-nucleotide polymorphisms with the tacrolimus dose requirements in renal transplant recipients
    Anglicheau, D
    Verstuyft, CL
    Laurent-Puig, P
    Becquemont, L
    Schlageter, MH
    Cassinat, B
    Beaune, P
    Legendre, C
    Thervet, E
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 (07): : 1889 - 1896
  • [3] Aucella P, 2012, J CHROM SEP TECH, V3, P1
  • [4] Liquid Chromatography-Tandem Mass Spectrometry or Automated Immunoassays: What Are the Future Trends in Therapeutic Drug Monitoring?
    Brandhorst, Gunnar
    Oellerich, Michael
    Maine, Gregory
    Taylor, Paul
    Veen, Gerhard
    Wallemacq, Pierre
    [J]. CLINICAL CHEMISTRY, 2012, 58 (05) : 821 - 825
  • [5] Pitfalls in monitoring tacrolimus (FK 506)
    Braun, F
    Schutz, E
    Christians, U
    Lorf, T
    Schiffmann, JH
    Armstrong, VW
    Schroter, W
    Sewing, KF
    Oellerich, M
    Ringe, B
    [J]. THERAPEUTIC DRUG MONITORING, 1997, 19 (06) : 628 - 631
  • [6] Low hematocrit and serum albumin concentrations underlie the overestimation of tacrolimus concentrations by microparticle enzyme immunoassay versus liquid chromatography-tandem mass spectrometry
    Brown, NW
    Gonde, CE
    Adams, JE
    Tredger, JM
    [J]. CLINICAL CHEMISTRY, 2005, 51 (03) : 586 - 592
  • [7] Comparison of low versus high tacrolimus levels in kidney transplantation: Assessment of efficacy by protocol biopsies
    Cosio, Fernando G.
    Amer, Hatem
    Grande, Joseph P.
    Larson, Timothy S.
    Stegall, Mark D.
    Griffin, Matthew D.
    [J]. TRANSPLANTATION, 2007, 83 (04) : 411 - 416
  • [8] Cotton C, 2007, THER DRUG MONIT, V29, P508
  • [9] Analytical performance characteristics of the Abbott Architect i2000 Tacrolimus assay; comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Abbott IMx methods
    De, Barun K.
    Jimenez, E.
    De, S.
    Sawyer, J. C.
    McMillin, G. A.
    [J]. CLINICA CHIMICA ACTA, 2009, 410 (1-2) : 25 - 30
  • [10] Ekberg H, 2007, AM J TRANSPLANT, V7, P160