Application of non-ionic surfactant as a developed method for the enhancement of two-phase solvent bar microextraction for the simultaneous determination of three phthalate esters from water samples

被引:34
作者
Bandforuzi, Samereh Ranjbar [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
机构
[1] Univ Mazandaran, Dept Analyt Chem, Fac Chem, NirooHavayii Blvd, Babol Sar 4741695447, Iran
关键词
High performance liquid chromatography; Non-ionic surfactant; Phthalate esters; Solvent bar microextraction; Water samples; LIQUID-LIQUID MICROEXTRACTION; SOLID-PHASE MICROEXTRACTION; HPLC-UV; EXTRACTION; CHROMATOGRAPHY; OPTIMIZATION; PLASTICIZERS; MICELLE;
D O I
10.1016/j.chroma.2018.05.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The extraction of phthalate esters (PEs) from aqueous matrices using two-phase solvent bar microextraction by organic micellar phase was investigated. A short hollow fiber immobilized with reverse micelles of Brij 35 surfactant in 1-octanol was served as the solvent bar for microextraction. Experimental results show that the extraction efficiency were much higher using two-phase solvent bar microextraction based on non-ionic surfactant than conventional two-phase solvent bar microextraction because of a positive effect of surfactant-containing extraction phase in promoting the partition process by non-ionic intermolecular forces such as polar and hydrophobicity interactions. The nature of the extraction solvent, type and concentration of non-ionic surfactant, extraction time, sample pH, temperature, stirring rate and ionic strength were the effecting parameters which optimized to obtain the highest extraction recovery. Analysis of recovered analytes was carried out with high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV). Under the optimum conditions, linearity was observed in the range of 1-800 ng mL(-1) for dimethylphthalate (DMP) and 0.5-800 ng mL(-1) for diethylphthalate (DEP) and di-n-butyl phthalate (DBP) with correlation determination values above 0.99 for them. The limits of detection and quantification were ranged from 0.012 to 0.03 ng mL(-1) and 0.04-0.1 ng mL(-1), respectively. The ranges of intra-day and inter-day RSD (n = 3) at 20 ng mL(-1) of PEs were 1.8-2.1% and 2.1-2.6%, respectively. Results showed that developed method can be a very powerful, innovative and promising sample preparation technique in PEs analysis from environmental and drinking water samples. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 39 条
[1]   Synthesis of nano-hydroxyapatite sorbent for microextraction in packed syringe of phthalate esters in water samples [J].
Amiri, Amirhassan ;
Chahkandi, Mohammad ;
Targhoo, Azadeh .
ANALYTICA CHIMICA ACTA, 2017, 950 :64-70
[2]   Solid-phase microextraction of phthalate esters from aqueous media by electrochemically deposited carbon nanotube/polypyrrole composite on a stainless steel fiber [J].
Asadollahzadeh, H. ;
Noroozian, E. ;
Maghsoudi, Sh. .
ANALYTICA CHIMICA ACTA, 2010, 669 (1-2) :32-38
[3]   Solid phase extraction of food contaminants using molecular imprinted polymers [J].
Baggiani, Claudio ;
Anfossi, Laura ;
Giovannoli, Cristina .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :29-39
[4]   Phthalate and adipate esters in Australian packaging materials [J].
Balafas, D ;
Shaw, KJ ;
Whitfield, FB .
FOOD CHEMISTRY, 1999, 65 (03) :279-287
[5]   Solvent bar microextraction using a reverse micelle containing extraction phase for the determination of warfarin from human plasma by high-performance liquid chromatography [J].
Bandforuzi, Samereh Ranjbar ;
Hadjmohammadi, Mohammad Reza .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1496 :1-8
[6]   Two-phase hollow fiber-liquid microextraction based on reverse micelle for the determination of quercetin in human plasma and vegetables samples [J].
Banforuzi, Samereh Ranjbar ;
Hadjmohammadi, Mohammad Reza .
TALANTA, 2017, 173 :14-21
[7]   Application of single-drop microextraction to the determination of dialkyl phthalate esters in food simulants [J].
Batlle, R ;
Nerín, C .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :29-35
[8]   Effects of xenoestrogenic environmental pollutants on the proliferation of a human breast cancer cell line (MCF-7) [J].
Blom, A ;
Ekman, E ;
Johannisson, A ;
Norrgren, L ;
Pesonen, M .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1998, 34 (03) :306-310
[9]   Membrane-based microextraction techniques in analytical chemistry: A review [J].
Carasek, Eduardo ;
Merib, Josias .
ANALYTICA CHIMICA ACTA, 2015, 880 :8-25
[10]   Correlation between different clean-up methods and analytical techniques performances to detect Ochratoxin A in wine [J].
Fabiani, Alessandra ;
Corzani, Claudia ;
Arfelli, Giuseppe .
TALANTA, 2010, 83 (01) :281-285