Impedance characterization of a piezoelectric immunosensor part II:: Salmonella typhimurium detection using magnetic enhancement

被引:31
作者
Kim, GH
Rand, AG
Letcher, SV [1 ]
机构
[1] Univ Rhode Isl, Dept Phys, Kingston, RI 02881 USA
[2] Univ Rhode Isl, Dept Food Sci & Nutr, Kingston, RI 02881 USA
关键词
impedance analyzer; biosensor; piezoelectric quartz crystal; Salmonella typhimurium; paramagnetic microsphere;
D O I
10.1016/S0956-5663(02)00143-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study investigated the usefulness and characteristics of a 5-MHz quartz crystal resonator as a sensor of biological pathogens such as Salmonella typhimurium. An impedance analyzer measured the impedance behavior of the oscillating quartz crystal exposed to various concentrations of Salmonella (10(2)-10(8) cells per ml). The Salmonella cells were captured by antibody-coated paramagnetic microspheres, and then these complexes were moved magnetically to the sensing quartz and were captured by antibodies immobilized on the crystal surface. The response of the crystal was expressed in terms of equivalent circuit parameters. The motional inductance and the motional resistance increased as a function of the concentration of Salmonella. The viscous damping was the main contributor to the resistance and the inductance in a liquid environment. The load resistance was the most effective and sensitive circuit parameter. A magnetic force was a useful method to collect the complexes of Salmonella-microspheres on the crystal surface and enhance the response of the sensor. In this system, the detection limit, based on resistance monitoring, was about 10(3) cells per ml. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 20 条
[1]  
[Anonymous], ANAL CHEM
[2]   RESPONSE OF A QUARTZ CRYSTAL MICROBALANCE TO A LIQUID DEPOSIT [J].
GLASSFORD, APM .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1978, 15 (06) :1836-1843
[3]  
GRATE JW, 1993, ANAL CHEM, V65, P987
[4]   Energy dissipation kinetics for protein and antibody-antigen adsorption under shear oscillation on a quartz crystal microbalance [J].
Hook, F ;
Rodahl, M ;
Brzezinski, P ;
Kasemo, B .
LANGMUIR, 1998, 14 (04) :729-734
[5]   Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid [J].
Horacek, J ;
Skladal, P .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :43-50
[6]  
KIM GH, 2003, IN PRESS BIOSENS BIO
[7]  
KOENIG B, 1993, ANAL LETT, V26, P1567
[8]  
Landau L., 1976, MECHANICS, V1
[9]   CHARACTERIZATION OF A QUARTZ CRYSTAL MICROBALANCE WITH SIMULTANEOUS MASS AND LIQUID LOADING [J].
MARTIN, SJ ;
GRANSTAFF, VE ;
FRYE, GC .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2272-2281
[10]   PIEZOELECTRIC CRYSTAL BIOSENSOR MODIFIED WITH PROTEIN-A FOR DETERMINATION OF IMMUNOGLOBULINS [J].
MURAMATSU, H ;
DICKS, JM ;
TAMIYA, E ;
KARUBE, I .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2760-2763